Filter Results By:

Products

Applications

Manufacturers

Test Receivers

Devices whose purpose is to capture transmitted signal energy and record specified characteristics. These recordings are then examined to ensure that the sending device is working according to specifications. (www.techfest.com)


Showing results: 346 - 357 of 357 items found.

  • Radar Simulation Software

    Pulse Sequencer - Rohde & Schwarz GmbH & Co. KG

    R&S®Pulse Sequencer software together with a vector signal generator from Rohde & Schwarz or just as software provides a compelling radar signal generation solution to engineers and technicians responsible for testing radar receivers. The solution is in line with the trend of testing more in the lab rather than expensive field testing. Co-engineered with the industry, the solution supports all relevant modern radar scenario test cases and can account for real-world environments. It uses commercially available R&S®Pulse Sequencer PC software and off-the-shelf Rohde & Schwarz vector signal generators.

  • Spectrum Analysis For E5081A Up To 20 GHz

    S960904B - Keysight Technologies

    The Keysight S960904 spectrum analyzer (SA) software application adds high-performance spectrum analysis to the E5081A ENA-X up to 20 GHz. With fast-stepped FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The application enables simultaneous spectrum measurements using test and reference receivers. The multichannel SA pairs with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application uses source-power and receiver-response calibration and fixture de-embedding, providing highly accurate in-fixture and on-wafer spectrum measurements.

  • Spectrum Analysis, Up To 13.5 GHz

    S930901B - Keysight Technologies

    The S930901B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 13.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • CPCI Or PXI PCM & ARINC 717 Board

    MS 1703 - Meltronics Systemtech

    *Bus Interface - PXI / CPCI Bus*Microprocessor and FPGA design based Board*One Channel ARINC 717 Transmitter and Receiver*Generates all PCM telemetry signals like NRZ, Bi-Phase, Differential Bi-phase, DM signals*Used to test all types of PCM based telemetry equipments*Configurable output signals format (parity, word length, Minor, Major frame, Bit position)*User can configure the words and there positions in the frame*The word can be either a square / triangle wave data or constant data*1 MB Shared Memory for Data Storage*Driver interface for Windows2000/XP/VISTA and LINUX OS

  • Spectrum Analysis For E5081A Up To 44 GHz

    S960907B - Keysight Technologies

    The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Pulse Pattern Generator, 3.35 GHz, single channel

    81133A - Keysight Technologies

    The Keysight 81133A single-channel 3.35 GHz Pulse Pattern Generator is the latest product in the long history of Keysights high-speed Pulse Pattern Generators. When timing and performance requirements are critical, for example in high-speed serial bus applications like PCI Express or Serial ATA, its fast rise times and low intrinsic jitter allow the precise and in-depth characterization of devices, e.g. receivers or backplanes. Like its predecessor, the Keysight 8133A, the new 81133A sets the standard for high-speed applications. The Keysight 81133A lets you test your DUT instead of the pulse or data source! For applications that require multiple output channels or multi-level signaling like pre- and de-emphasis (PCI Express) or squelch (Serial ATA), please refer to the 81134A.

  • Telemetry Transmitter for FM with up to 3 Bands

    LS-11-F - Lumistar Inc.

    The LS-11-F portable FM test transmitter is designed for checkout and troubleshooting of telemetry receiving systems operating with FM modulation. For applications with any of the ARTM modulations (Tier 0, Tier I, or Tier II), please refer to the LS-11-M Data Sheet. Complete ground stations including the antenna with LNA, RF down-converter, IF receiver, bit synchronizer, and PCM decommutator can be tested and bit error tests performed. The design allows secure links to be tested with an external encryptor. The Test Transmitter contains an internal PCM Data Simulator and Pseudorandom patterngenerator that operates in a BERT mode. The device provides simulated clock and data (without transmitter enabled) and accepts external data for modulating the internal transmitter. Complete setup can be achieved locally through the keypad and two-line LCD display or remotely through the USB Interface. Operational parameters include the PCM format parameter database information (frame sync patterns, wavewords, etc…), pre-modulation filter selection, transmitter carrier frequency, transmitter deviation, and output power level. Output power can be selected from approx. -60 to +5 dBm in 5 dB steps. The Test Transmitter contains a LiFePO4 Battery (Lithium Iron Phosphate), which provides higher energy density at ¼ the weight of legacy lead-acid batteries. The unit also provides an internal battery charger and will operate for up to twelve hours on battery power having received on a full charge.

  • Rockwell Hardness Tester

    Sinowon Innovation Metrology Manufacture Ltd.

    ◆ Semi-automatic intelligent Digital Rockwell Hardness tester, you can automatically test the Rockwell hardness and surface Rockwell hardness measurement;◆ Automatic variable load, automatic loading, automatic unloading, automatic conversion, automatic measurement;◆ Friendly human-computer interaction,5.2“colorful LCD screen direct display test force,loading time,conversion value and indenter type etc; ◆ Automatically calculate and display the measured value, the maximum value, the minimum value, the average value and the hardness value deviation, the display shows the resolution 0.1HR;◆ There are functions such as hardness upper and lower limit settings, tolerance alarms, data graph analysis, average and (single point) batch measurement modes;◆ Software compensation function, the machine can be ± 3HR software compensation, no need to open the top cover for mechanical adjustment;◆ With automatic hardness conversion function, according to ASTM E140 conversion, no need to check the complex hardness of the table;◆ Multi-language features, can switch Chinese, English, German, Portuguese, Turkish, Czech, Korean and other languages;◆ Built-in 2000 single data storage function and 1000 group packet data storage function, can view a single data and data analysis;◆ Optional Bluetooth wireless printer to print the measurement data, no need to manually record and write test data;◆ Optional Softhard data analysis software and Bluetooth receiver on the test data for the computer into and analysis;◆ Support FexQMS measurement of large data analysis and control software to enhance the whole plant process control, reduce material loss.

  • Car-to-X Signal Strength Emulator

    Qosmotec Software Solutions GmbH

    QPER-C2X is a special adaptation of the signal strength emulator QPER, designed for mobile and Vehicular Ad-hoc Networks (MANet and VANet). Every radio devices in such an infrastructure-less network acts as a sender, receiver, and forwarder (router). Therefore, the ports of the QPER-C2X hardware are fully connected with each other by dynamically controllable attenuators. The system is fully designed for frequencies up to 6 GHz, since wireless communication for Intelligent Transport Systems (ITS) is based on the WLAN standard IEE 802.11p from 5.850 MHz to 5.925 MHz. The connected ITS stations can be either on-board units, as they are built into cars, or road side units that are used by road infrastructure (traffic lights, road work area delimiters, velocity signs). For tests in the lab, radio modules of such ITS stations are each kept in a shielding box that prevents any unwanted radiation over the air.

  • 16-Bit Multi-Function With A/D, D/A And Digital I/O Channels CPCI Cards

    GX3232 Series - Marvin Test Solutions, Inc.

    The GX3232 is a multi-channel 16-bit, analog input and output cPCI module, supporting 32 single-ended or 16 differential input channels and four analog output channels. The inputs can be software configured for differential or single-end operation and are sequentially scanned with a maximum aggregate scan rate of 300 kS/s. Three input ranges are software-selectable: ±10 V, ±5 V or ±2.5 V. Optionally, the GX3232 is available with a high voltage input configuration and supports three ranges: ±60 V, ±30 V and ±15 V. The high voltage configuration supports 16 single-ended or 8 differential input channels for high voltage and 16 single-ended or 8 differential inputs for low voltage measurement. Four analog output channels provide software-selectable output ranges of ±2.5 V, ±5 V or ±10 V. The outputs can be updated either synchronously or asynchronously and support waveform generation. Each output can be clocked at rates up to 300 kS/s. A 16-bit digital I/O port is also provided, which supports 16 bidirectional data lines. Note that when used with a TS-700 system only 8 of these digital I/O lines are available at the test system's receiver interface.

Get Help