Showing results: 3856 - 3870 of 14470 items found.
-
TEST-901 -
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
TEST-630 -
Beijing GFUVE Electronics Co.,Ltd.
Test-630 multi Phase Universal protection relay test set have 6U6I output, it is a universal protection relay tester with eight pairs of binary input and four pairs of binary output
-
MOTOMEA
High Speed EV Motor - Unique Testing capabilities (MEA patented Inertial Dynamometer)Complete load testing of high speed EV motors (for example: 75kW, 32000 rpm)Load testing without connecting the EV motor to any mechanical loadRipple Torque, Friction Torque, Friction Spectrum, Speed & Torque Spectrum, Back EMF
-
PSL-3424 Quick Test for 802.at and 802.3bt PSE's -
Sifos Technologies, Inc.
*Accessible from PSA Interactive or PowerShell PSA*Scans 2 to 8 PSE ports per test cycle*Automatically determines and adapts to PSE maximum assigned class*Tests PSE’s that grant full power via PD Classification or through PoE LLDP*Validates PoE Detection Acceptance and Rejection Range*Measures PSE Port Voltage at both minimum (DC MPS) and maximum (Pclass) load conditions*Reports PSE type (AT vs BT), maximum assigned class capability, and Pclass power capacity*Assesses Disconnect Power Removal response*Assesses Overload Power Removal response*Assesses LLDP Power Protocol and Allocations (PSL-3424L)
-
Guangdong Bell Experiment Equipment Co.,Ltd
Walk in chamber for Complex Salt Spray Test Relevant standards requirement1. Test Object: battery pack andsystem.2. Refer GB/T4 part 5.5.2 test method, test according to GT/T2423.17 test conditions.3. The salt solution was made up with sodium chloride (chemically pure and analytically pure) and distilled or deionized water,Its concentration is (5 + 1)% (mass fraction).4. (35 ± 2) ℃, the measured pH value is between 6.5-7.2.5. Placed the test objects in the salt spray chamber for cycling test. Each cycling duration for 24h. Spray salt solution to the test object for 8 hours under the temperature of (35± 2) ℃ , remain for 16 hours. Between the forth and the fifth hour in one cycles should be according to test requirement in GB/T 28046.1-2011, test mode with 3.2.6. Total 6 cycles testing.7. Salt spray test is not necessary for the test objects being installed in passenger, luggage or cargo compartments.
-
Sifos Technologies, Inc.
The optional PSL-3424-QT feature license opens up two important productivity tools in the PSL-3424 platform. PSL-3424 Quick Test is a fully automated PSE functional test covering between 2 and 8 PSE ports in a test cycle with average test times on the order of 10 seconds per port tested. The Chained Data Test user interface allows rapid construction and verification of test setups used in “snaked data path” testing of PSE’s with user specified loads and optional LLDP power negotiation on each test port.
-
Shanghai Guantu Technology Co., Ltd.
The high (medium) voltage TOV tester is used for transient overvoltage tests caused by faults in high and medium voltage systems such as surge protectors (SPDs), and can also be used for other scientific research tests.standardGB/T 16927-1997 High voltage test technology.GB18802.1-2011 Surge protective device (SPD) for low-voltage power distribution system Part: Performance requirements and test methods.IEC61643-1:2005 (Surge protective devices connected to low-voltage power distribution systems part 1: Performance requirements and testing methods)TOV fault test equipment1. Three-phase isolation test transformer2. Single-phase test transformer3. Low voltage switchgear4. Power controller5. Test voltage and current measurement6. Sample box
-
Keystone Compliance
Ingress protection testing tests the level of protection an enclosure provides against intrusions. One such set of ingress protection tests involves exposing the equipment under test (EUT), to high-pressure and high-temperature water jets. These tests are numbered IPX9. The first digit, represented by the “X”, ranges from 0 to 6 and specifies the protection from solid particles. The second digit, in the case of the high-pressure and high temperature water jets ingress protection test, would always be a 9.
-
Dayton Audio
Designed for use with the Omnimic but is also useful as a standalone test CDGreat for setting amplifier gain levels19 test tracks
-
85130G -
Keysight Technologies
The Keysight 85130G test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a NMD-2.4 mm (f) to NMD-2.4 mm (m) adapter and a NMD-2.4 mm (f) to PSC-2.4 mm (f) adapter. The frequency range for these adapters is dc to 50 GHz with a return loss of 23 dB or better.
-
85130D -
Keysight Technologies
The Keysight 85130D test port adapter protects the test set port from being directly connected to the device under test. These adapters have a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a 3.5 mm to PSC-3.5 mm male adapter and a 3.5 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 28 dB or better.
-
85130H -
Keysight Technologies
The Keysight 85130H test port adapter protects the test set port from being directly connected to the device under test. This adapter has a special rugged female connector that connects to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. This set contains a 1.85 mm to 1.85 mm male adapter and a 1.85 mm to 1.85 mm female adapter. The frequency range for these adapters is dc to 67 GHz with a return loss of 23 dB or better.
-
85130F -
Keysight Technologies
The Keysight 85130F test port adapter protects the test set port from connecting directly with the device under test. It has a special rugged female connector designed for connecting to the network analyzer test port. This special connector does not mate with a standard male connector but converts the rugged test set port to a connection that will mate with the device under test. The set contains a 2.4 mm to PSC-3.5 mm male adapter and a 2.4 mm to PSC-3.5 mm female adapter. The frequency range for these adapters is dc to 26.5 GHz with a return loss of 26 dB or better.
-
SigBase -
Spherea Technology Ltd.
SigBase is an Integrated Development Environment for the creation and execution of IEEE 1641 test programs. It supports the development of tests using flow-charting techniques and the graphical design of signals using newWaveX. It includes fully integrated compilation and signal path allocation software that determines the appropriate instrument and switch path for each signal and test. The run-time system, which is also available as a separate product for use on multiple test stations, controls the operation of the ATS and can provide test results in ATML format.
-
Eltel Industries
*AC and DC test Voltages switched internally.*Direct digital display of test voltages.*Auto ranging and direct read out of volume resistivity.*Cell constant adjustment and Tan Delta zero correction.*Built-in protection for test sample flash over.