Showing results: 451 - 461 of 461 items found.
-
M9033A -
Keysight Technologies
The M9033A PXIe System Synchronization Module is a dual-slot, 5-port module that provides multi-module and multi-chassis synchronization and triggering for Keysight's modular instruments.
-
M9023A -
Keysight Technologies
The M9023A is a PXIe System Module and is installed in the system slot of a PXIe chassis. When combined with an appropriate host adapter, it will provide a high data BW connection between the host PC and the chassis. The M9023A has a flexible configuration capability. Each card has two Gen 3 x8 PCIe cable links capable of achieving speeds up to 8 GB/s on each port. These two ports can be combined into a single x16 cable link providing a speed of up to 16 GB/s. This means a data-intensive system can be built using high-performance desktop or rack-mounted computers.
-
DAQe-2500 Series -
ADLINK Technology Inc.
ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.
-
40-412A-024 -
Pickering Interfaces Ltd.
16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
42-412A-021 -
Pickering Interfaces Ltd.
The 40-412A-021 (PXI) and 42-412A-021 (PXIe) are 64-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
40-412A-021 -
Pickering Interfaces Ltd.
The 40-412A-021 (PXI) and 42-412A-021 (PXIe) are 64-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
42-412A-024 -
Pickering Interfaces Ltd.
The 40-412A-024 (PXI) and 42-412A-024 (PXIe) are 16-Channel Digital Output modules with high output voltage and current capability. The outputs can be used for high or low drive and each channel is capable of sourcing 0.5A from the high side or 0.5A sink on the low side. Accidental operation of both high and low side driver on the same channel is prevented by the supplied driver. Outputs are fully protected against over-voltage, over-current and thermal overload, ensuring robust and reliable operation in the toughest test environments. For high side driving, the voltage source is supplied externally, allowing the module to drive high capacity loads separate from the chassis power supply. For low side driving, the external source is not used and the module’s output operates an open collector or open drain driver.
-
40-414-101 -
Pickering Interfaces Ltd.
The 40-414-101 (PXI) and 42-414-101 (PXIe) are 128-channel digital input modules with 50 V inputs and provide a convenient way of determining the status of input lines by comparing the input voltage with two threshold voltages - quickly establishing if the input is low, high or in an intermediate logic state.
-
42-414-101 -
Pickering Interfaces Ltd.
The 40-414-101 (PXI) and 42-414-101 (PXIe) are 128-channel digital input modules with 50 V inputs and provide a convenientway of determining the status of input lines by comparing the input voltage with two threshold voltages - quicklyestablishing if the input is low, high or in an intermediate logic state.
-
783731-01 -
NI
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
ND-6060 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.