Showing results: 5566 - 5580 of 8504 items found.
-
1125 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test button.
-
1126 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test button.
-
N9030B -
Keysight Technologies
Accelerate innovation in demanding applications with measurement options that range from excellent to exceptionalExtend frequency up to 110 GHz with Keysight smart mixersCapture transient or intermittent signals with real-time spectrum analysisSimplify application-specific testing with X-Series appsPerform deeper troubleshooting with the 89600 VSA software
-
DSR 100 Series -
AE Techron, Inc.
DSR 100 Series systems provide complete, single-box solutions for immunity testing. They include a simple-to-use yet powerful standards waveform generator matched with an industry leading power supply technology and come with an extensive library of tests for many automotive and aviation standards.
-
TRIO-TECH International
The COBIS-II Series Burn-in System is designed to test the latest high frequency integrated circuits (ICs) and combines a large capacity oven with well proven Accutron FlexBID™ dynamic driver technology. This system is engineered for productive dynamic device testing and reliable monitoring.
-
M9243A -
Keysight Technologies
1 GHz bandwidth oscilloscope2 analog channels5 GSa/s sample rate1,000,000 wfms/s update rate Isolate signals in seconds with exclusive zone triggering Additional options: 20 MHz arbitrary waveform generator, 3-digit voltmeter, serial trigger and analysis and mask testing
-
DP0001A -
Keysight Technologies
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
AmFax Ltd
PXI has become the de-facto standard for housing the high performance modular instrumentation required to meet the demands of testing today's high performance products. Based on the PCI bus, PXI (PCI Extensions for Instrumentation), this platform is used in most of our new ATE designs.
-
DRK-150F -
Shandong Drick Instruments Co., Ltd.
The constant temperature and humidity chamber has an accurate temperature and humidity control system, which provides various environmental simulation conditions required for industrial research and biotechnology testing, so it can be widely used in sterility tests, stability inspections such as pharmaceuticals, textiles, and food processing.
-
3380P -
Chroma ATE Inc.
The 3380D/3380P/3380 test system have 4 wires HD VI source and any-pins-to-any-site high parallel test (multi-sites test) functions (512 I/O pins to test 512 ICs in parallel) that can meet the upcoming higher IC testing demands.
-
3380D -
Chroma ATE Inc.
The 3380D/3380P/3380 test system have 4 wires HD VI source and any-pins-to-any-site high parallel test (multi-sites test) functions (256 I/O pins to test 256 ICs in parallel) that can meet the upcoming higher IC testing demands.
-
HIACC Engineering & Services Pvt. Ltd.
Designed as per ISTA packaging standard, the Pneumatic Zero Drop Test stand is used to assess the drop bearing capacity of the specimen during its transportation and handling process. The system is ideal for testing the specimen vulnerability around edges, surfaces and corners at different heights.
-
6500 series -
Chroma ATE Inc.
The global AC power testing requirements demand more sophisticated AC Power Source that is capable of simulating a wide variety of AC line conditions, harmonic waveforms, accurate power measurement and analysis. The Chroma 6500 series Programmable AC Power Source delivers the right solution to simulate all kinds of normal/abnormal input conditions and measure the critical characteristics of the product under test. It can be used for R&D design characterization, production testing, and QA verification of commercial, industrial, and aerospace electronic products. The Chroma 6500 series delivers maximum rated power for any output voltage up to 300 Vac, and at any frequency between 15Hz to 2000Hz. It is suitable for commercial applications (47-63Hz); for avionics,marine, military applications at 400Hz or higher frequency; or for electrical motor, air-conditioner test applications at 20Hz. All models generate very clean sine or square waveforms output with typical distortion less than 0.5%. The Chroma 6500 series has built-in Direct Digital Synthesis (DDS) Waveform Generator to provide user programmable high precision waveform. For testing products under AC line distortion conditions, clipped sinewave can be generated with 0% to 43% distortion and amplitude from 0% to 100%. It also can simulate all kinds of power line disturbances such as cycle dropout, transient spike, brown out, phase angle, voltage and frequency ramp up (ramp down), etc.. Up to 30 harmonic waveforms are factory installed, and testing for compliance to AC line harmonic immunity standards can be easily achieved in the field.
-
EMC-3C -
MVG EMC
This compact 3 meter test range will settle into test areas of limited space while continuing to produce exceptional performance for EMC measurement. Emission quiet zones of up to 1.5m are accommodated with very repeatable results. Suitable for EMC pre-compliance emissions and compliant immunity testing.
-
Labfon Equipment Inc.
Flame Photometers are used widely in the measurement of alkali elements concentration in all sample types in: Mineral Extraction, Oil Industry, Paper Industry, Pharmaceuticals, Soil Analysis, Utilities, Food & Beverage, Chemical Manufacture and Fertilizer and Clinical laboratory testing and Pathological study in medical health.