Filter Results By:
Products
Applications
Manufacturers
Thermal Chucks
control DUT's thermal state. Wafer
See Also: Temperature Forcing Systems, Wafer Probers, Temperature Chucks
-
product
Thermal Chuck Systems
C-Series
Advanced Temperature Test Systems GmbH
Looking for a chuck system that gives you the possibility to cool down to - 60C and up to + 300C. The C-Series represents a product line of air cooled thermal chuck systems for a wide temperature range
-
product
Thermal Chuck Systems
A-Series
Advanced Temperature Test Systems GmbH
The A-Series represents a productline of air cooled thermal chuck systems for a temperature range between -30C up to +400C. The basic product offers an active cooled chuck system without an external chiller for a temperature range between +25C up to +200C at a very competitive price to common Hot Chucks.
-
product
Thermal Chuck Systems
L-Series
Advanced Temperature Test Systems GmbH
The perfect system for high power applications with an extraordinary performance at a wide temperature range between - 65C and + 300C.Each system contains a high performant liquid-cooling unit.
-
product
Thermal Controlled Chucks & Plates
TOP Cool
Mechanical Devices newest innovation in thermal testing. Each TP system contains a thermal chuck or thermal plate and a self-contained thermal control unit.The TP chuck and platforms is a breakthrough product that introduced the use of refrigerant for active cooling & heating of wafers and other components with no need of chiller, CDA, or consumable and expensive refrigerants such as liquid nitrogen and liquid carbon dioxide. It can be a perfect replacement system in the industry for uncompromising thermal and mechanical performance with a temperature ranging from -60 to +220°C.
-
product
Wafer Chucks
American Probe & Technologies, Inc.
High Performance Chuck for your needs Introducing the American Probe & Technologies’ HC-6000 series of thermal chucks,
-
product
Semi-Automatic Probe Station
P300A
The P300A probe station is the most stable, intuitive, and space efficient 300mm semi-automatic analytical probe station available today. Designed for low current, sub-micron positioning applications, the P300A comes standard with features such as single-point ground, dry/dark environment, and integrated thermal chuck plumbing.
-
product
Pyroelectric and Thermal Testing
The optional Chamber Task measures the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled within a thermal chamber, on a hot chuck or in a furnace. From these measurements the Spontaneous Polarization Pr(q) and the Dielectric Constant er(q) are computed. These are then combined to determine the Electrical Displacement D(q) as a function of the temperature q.
-
product
Chamber/Pyroelectric Task
Radiant's Chamber/Pyroelectric Task sets the sample to a series of temperatures by performingGPIB control of an external thermal device. At each temperature it captures the sample’s polarization response and/or small-signalcapacitance. These are combined to calculate the pyroelectric coefficient. The Pyroelectric Task is to be used with a Radiant Test System and a Linkam Stage (-196C to 600C), Thermal Chambers, Hot Chucks, or a Furnace to automatically measure the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled. Radiant's Pyroelectric measurement Task can be added to Vision at additional cost. This measurement suite fully characterizes the pyroelectric charge (polarization) response of the sample under test. The Pyroelectric Task suite controls various thermal controllers such as Quantum Design, Lake Shore, Delta Design, and many others. Detailed Listing of Thermal Controllers Registered in Vision. The Chamber/Pyroelectric Task is quoted upon request.
-
product
Automated Probe Stations 200 - 300mm
P200L or P300L
The Micromanipulator P300L 300mm semiautomatic probe station comes standard with features such as single-point ground and integrated thermal chuck plumbing. Built for reliability as well as precision, the P300L features leadscrew – leadnut stage and platen drives, a stainless steel platen with removable front wedge and high stability microscope bridge that supports all high resolution long-working distance microscopes.The P300L ‘s versatile controller supports USB and GPIB communications (configured with proper options). The stage X-Y and platen (Z) are motorized / programmable. Microscope motorized / programmable control is also an option. The system may be controlled via scripts and all popular parametric test analytical prober drivers. An indexing script with user GUI and a Labview VI is provided allowing use of the system right out of the box.Micromanipulator strives to ensure our semiautomatic systems are flexible so that applications like Magnetic sensitivity testing, Probe cards, mmW, Wafer & Board level testing. Once you have developed your testing plan we also have great relationships so we can move you into a fully automatic probe station if needed.Joystick control allows for easy and quick operation when programmability is not required. The joystick intuitively operates the station stage, platen, and microscope for systems so configured.The P300L may be configured with a local dry / shielded / dark environment “Top Hat” for low level or low temperature, frost free probing. Three temperature ranges are supported:Ambient (room temperature) to 300C0C to 300C-55C to 300CThe P300L is the station of choice for a high performance, full capability and cost-effective 300 mm semi-automatic probe station.
-
product
Probe Station
ETCP1000
Installation of “Hot and cool chuck” - Sellectable chuck size : 4inch, 6inch. - Temperature variation : -193°C ~ 300°C (80K ~ 573K) - Additional requirements : Vacuum chamber, LN2 tank(Bombei), microscope, CCD camera, manipulators. - EPS500 is standard model in ETCP1000 probe station.
-
product
Ambient Temperature Vacuum Wafer Chucks
6" (152mm) Vacuum Wafer Chuck for General Purpose Ambient Temperature testing with a Stainless Steel vacuum wafer surface
-
product
On-Wafer Measurements
Accurate DC/CV (and RF) statistical modeling of semiconductor devices requires collecting a significant amount of measured data from different wafers across several temperatures. Keysight Technologies recommends IC-CAP WaferPro as a turn-key DC/CV and RF automated characterization solution to help modeling and device engineers achieve more efficient on-wafer measurements across temperature. This new breakthrough solution is based on IC-CAP modeling software and efficiently controls DC/CV analyzers, network analyzers, probers, switching matrixes, and temperature chucks, as well as the powerful 407x and 408x Series of Keysight parametric testers.
-
product
Vacuum Chuck Temperature Controlled Test Stations
These test stations offer the same reliable repeatable measurement capability of our temperature monitored stations with the added dimension of temperature control.
-
product
Electrostatic Chucks
Chucks grip for micropatterning, temperature control, or robotics ...*insulating substrates,*hard disk drive head substrates,*semiconductor wafers,*InP-coated sapphire,*metal foils,*... and many other materials.
-
product
High Temperature Chucks
High temperature electrostatic chucks are available for the ranges -60 to +400 deg. C, and for 350 to 600 deg. C. Different materials and constructions are used in these two ranges.