Filter Results By:

Products

Applications

Manufacturers

Thermocouples

Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.


Showing results: 451 - 465 of 581 items found.

  • Temperature Sensors

    PCE Instruments

    We offer a variety of models of type-K temperature sensors / thermocouples. There is a standard temperature sensor, such as: surface sensor, penetration sensor, immersion sensor or special sensor with an adhesive tape, a patch, a Temperature Sensor overview screw, or a flexible cable. Consider the different combinations of materials and measurement ranges of a temperature sensor. With the help of thermal elements, temperature measurement problems can be solved in industrial processes, in machines and installations, such as in the environmental sector, and reliable results obtained.

  • Multi-Channel Telemetry

    Accumetrics Associates, Inc.

    The AT7000 multi-channel systems can combine any customized mix of ordinary sensors: strain gages, thermocouples, RTDs, accelerometers, as well as motor/generator field voltages, currents and ground fault currents. The received data is continuously streamed to the user as analog (+/- 10V or 4/20mA) or digital data.

  • OEM 1-Channel Fiber Optic Signal Conditioner PCB Module

    FOTEMP1-OEM-MNT - Micronor AG

    The FOTEMP1-OEM-MNT is a small form factor PCB interface module designed for low cost insertion of high precision GaAs-based fiber optic temperature sensor technology into OEM applications where common electrical temperature sensors and thermocouples cannot be used. The OEM interface product is compatible with all TS series fiber optic temperature probes. The sensors are entirely non-metallic and electrically passive, providing immunity to EMI, RFI, MR, microwaves and radiation is required.

  • Temperature Controllers

    WIKA Alexander Wiegand SE & Co. KG

    The compact temperature controllers from WIKA offer display, control and monitoring of temperatures. The configuration of the sensor input is made via the multi-function input. Resistance thermometers, thermocouples and standard industrial signals, such as 4 ... 20 mA, serve as the input variable of a temperature controller. The monitoring output can be set either as relay (for slow control), as logic level for the control of electronic solid-state relays (for fast control and high current loads) or as a continuous 4 ... 20 mA output.

  • 4 Digits Temperature(TC) Meter

    CM1-TC - Chuan Sheng Electronics Co., Ltd.

    CM1-TC Thermocouple Temperature Meter has been designed in simple function and 4 digital 20.0mm LED displays with economic cost.They are can be programmed by tact switches that are hidden in front panel.They are also available to option relay output or an analog output or RS485(Modbus RTU Mode) communication.

  • Temperature Calibration

    Calmet Ltd.

    In our temperature lab we have the capability calibrate a wide range of temperature products such as catering food probes from deli to restaurant, industrial systems for manufacturing and quality checks using thermocouples surface probes or insertion probes we also calibrate IR (Infrared) thermometers.

  • Temperature Data Acquistion

    THERMES-USB RF - Physitemp Instruments

    Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. For information on our wide selection of Type T Thermocouple temperature probes.

  • Cooking Alarms

    ThermoWorks

    High quality, accurate cooking alarm thermometers (sometimes called leave-in probe oven alarms) are critical to the success of any process that requires maintaining a target temperature over time, including grilling, smoking, and roasting meats, baking breads and pastries, candy making, home brewing and much more. Choose from two-button simplicity, high and low alarms, continuous min/max display, single or dual channel, trim cal features, and thermocouple or Pro Series® probes.

  • Digital Indicators

    NOSHOK, INC.

    NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.

  • Single Cell Hardware

    Fuel Cell Technologies, Inc

    A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).

  • Temperature Calibrators

    Fluke Calibration

    Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.

  • THERMO MODULE OF THE COMPACT DEVICE FAMILY

    ES620 - ETAS GmbH

    This module measures temperatures using 16 electrically insulated measuring channels for temperature sensors. The adjustable acquisition rate per module is 10 samples/s to 0.1 samples/s. Signal smoothing occurs through a parameterized software filter, and high measuring accuracy is possible through 21 Bit resolution. The automotive measuring range is -210 C to 1372 C (-346 F to 2502 F); J, K, and N type thermocouples are used. Data transfer to PC occurs via Ethernet.

  • Alarms

    DEVAR Inc.

    Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.

  • Data Acquisition Recorders & Loggers

    DAS1800 - B&K Precision Corporation

    The DAS1800 can be configured for a wide variety of applications with slots for 10 input modules each supporting 4 or 8 measurement channels. Acquire data from any sensor with a voltage or current output (with shunt), or directly measure voltage, resistance, or temperature using thermocouples or resistance temperature detectors (RTDs).

  • Mezzanine System

    5085 - Abaco Systems Inc

    ECM P/N 5085 provides two channels of 24 bit A/D conversion suitable for high resolution low speed applications, which include bridge circuits, thermocouples, RTD and voltage measurements. For bridge applications each channel provides a fused +5 Volt or a current source drive.