Showing results: 76 - 90 of 485 items found.
-
TMTeck Manufacturing Limited
Non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.
-
CHY 113 -
TOMSAD
It is usded to measure the thickness of metallic coatings (eg paint) only on substrates with ferromagnetic alloys (eg steel). The meter is designed to provide easy operation in one hand.
-
Rinch Industrial Co.,Limited
Used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing.
-
SI-1098 -
Smartech Inc.
Coating Thickness Gauge SI 1098 is a highly intelligent and precise instrument used to quickly and accurately measure thickness of coating or plating on almost all kinds of metal surface. Technology – Magnetic Induction – (enables measurement of non magnetic coatings on magnetic substrates such as Steel, Mild Steel, Cast Iron &Magnetic Stainless Steel). Example coatings:- Paint,Zinc / Galvanising, Chrome, Copper, Enamel, Rubber, Paint, Varnish, Powder Coating, Plastic etc.
-
SI-1099 -
Smartech Inc.
Coating Thickness Gauge SI 1099 is a highly intelligent and precise instrument used to quickly and accurately measure thickness of coating or plating on almost all kinds of metal surface. Technology – Magnetic Induction – (enables measurement of non magnetic coatings on magnetic substrates such as Steel, Mild Steel, Cast Iron &Magnetic Stainless Steel). Example coatings:- Paint,Zinc / Galvanising, Chrome, Copper, Enamel, Rubber, Paint, Varnish, Powder Coating, Plastic etc.
-
LAP GmbH
For the manufacturing of a perfect cold strip, many factors are crucial. Our measuring frames specifically check the thickness-related quality parameters of the strip steel or steel sheet. Free of radioactive radiation, laser sensors are used in the cold strip areas that do not require protection measures with laser class 2, or only low precautions when using laser class 3B sensors. The installation of our measurement systems is quick and uncomplicated for our customers. The CALIX is integrated into the line with its C-shaped frame across the material flow. Our solutions with and without traversing determine all important parameters for quality assurance, including strip thickness, edge thickness, wedge or cambering, and measure the complete thickness profile. Thus, you have full process control in the current production.
-
MX Series -
Qualitest International Inc.
Qualitest covers a complete and competitive range of Thickness Testers for plastic films, composite films, adhesives, adhesive tapes, laminated films, plastic films, paper and other materials.
-
Sheen Instruments
Using the magnetic attraction principle, this traditional gauge offers reliable thickness measurement of coatings, electroplating, enamel, rubber, electroplated nickel on steel, or electroplated nickel on non-ferrous substrates.
-
3233 -
Elcometer Limited
Available in aluminium or stainless steel this instrument consists of two concentric cylinders, one sliding inside the other. A spherical glass lens, which has engraved measurements, is fitted to the end of the central cylinder and when pressed into the wet film, leaves a circular trace.The diameter of the mark on the lens is measured and, using the supplied conversion table, the thickness of the coating can be easily assessed.Ideal for measuring the thickness of wet translucent products such as varnishes, oils etc.Measurement range of 2.25 - 360μm (0.09 - 14.17mils)
-
TI-45 Series -
JFE Advantech Co., Ltd.
You can instantly measure the thickness of a material simply by positioning a probe. This innovative gauge is widely used and is capable of measuring a variety of materials including iron, stainless steel, glass and ceramics.
-
Guangzhou Amittari Instruments Co.Ltd
The Basic Type Coating Thickness Gauge AC-110 Series have two types: Type C ( Integral Type ), Type CS ( Separate Type ); Suitable for automotive, paint layer coating thickness measurement; Integral Type suitable for single-hand operation, large probe with large contact surface have better stability, users can get continuous, good repetitive and precise measurements. Separate Type can provide several type probe, measure can be more flexibility. It is a kind of portable measuring instrument, it can quickly, no damage and precise coating, coating thickness measurement. Not only can be usedin the laboratory, also can be used in the engineering field. Through the use of different measuring head, but also can meet the needs of a variety of measurement. Widely used in manufacturing, metal processing industry, chemical industry, commodityinspection and testing field. Is the material protection professional.
-
Extech CG206 -
Extech Instruments Corporation
Dual technology provides automatic recognition for ferrous and non-ferrous substrates without having you guess the material. Allows for quick, one-handed operation, non- destructive measurement of the coating thickness on various surfaces.
-
TF640 -
TESTEX Testing Equipment Systems Ltd.
The gauge is positioned on the carpet and six loaded needles penetrate the pile until they make contact with the denser backing. The pile surface is located by a flat probe. The pile thickness can then be read directly from the digital gauge.
-
MMX 6 + MMX 6DL -
List Magnetik GmbH
The new wall thickness gauges MMX-6 and MMX-6DL includes all the features of the MX devices with the additional unique possibility to measure on coated parts without the coating is applied in the measurement (Echo Echo + pulse-echo function)
-
Extech CG104 -
Extech Instruments Corporation
The CG104 is a pocket-sized coating thickness tester which offers quick one-handed operation and non-destructive measurements of the thickness of ferrous and non-ferrous substrates. Its unique reversible display allows you to take readings in challenging angles of area being measured, plus it has an easy-to use menu system and backlit display feature. Built-in memory stores/recalls up to 255 readings. Complete with two AAA batteries, calibration standards (one ferrous plate, one non-ferrous plate and one standard coating plate film), wrist strap and soft case.