Filter Results By:

Products

Applications

Manufacturers

Showing results: 2716 - 2730 of 5310 items found.

  • Radio Trigger Module

    RTM3 - Seismic Source Co.

    The Remote Trigger Module 3, or RTM3 3, is a new generation of impact trigger device. It is designed to time synchronize a single seismic source unit with multiple seismic recorders. It can also be used to synchronize multiple seismic recorders. The RTM3 units use an internal high accuracy oscillator that is synchronized to GPS timing information. Each RTM3 unit requires an external GPS receiver with valid satellite information to synchronize the internal clock. Once the internal clock is synchronized the RTM3 can be used without any GPS signal for up to 10 minutes.

  • Software

    Electrochemistry Tests - Materials Development Corporation

    CyclicVoltammetry and Galvanostatic Charging are tests used throughout the industrial and scientific communities to study chemical reactions and behavior of electronic structures.  They are extremely helpful in the monitoring of nano based dielectrics, used in super /ultra capacitors or self-assembled monolayers (SAMs). The Cyclic Voltammetry test applies a ramping voltage to a device and measures the resulting current.  In acapacitor-like structure the current reveals loss in the dielectric as well as degradation over time.  CyclicVoltammetry is used to characterize the performance of supercapacitors and ultracapacitors formed using various nano-technologies.  It is also useful in the studies of self-assembled monolayers used for sensors.

  • Sound Level Meters & Noise Meter

    Cirrus Research plc

    Cirrus offers a range of Class 1 and Class 2 hand-held sound level meters and accessories to cover all noise measurement applications from simple noise tests to detailed noise analysis. Our range of Sound Level Meters and Noise Meters spans simple instruments that provide the measurement of Sound Level, Integrating-Averaging instruments that provide Leq and occupational noise functions as well as precision data logging sound level meters with 1:1 & 1:3 real time octave band filters and in-measurement audio recording.

  • SparkFun ToF Range Finder Breakout for VL6180

    12784 - SparkFun Electronics

    This is the SparkFun "Time-of-Flight" Range Finder, a breakout for the VL6180 distance sensor. Unlike most distance sensors that rely reflected light intensity or reflected angles to determine range, the VL6180 uses a precise clock to measure the time it takes light to bounce back from a surface. This affords the ToF Range Finder and VL6180 a great benefit over other methods because it can be much more accurate and more immune to noise. Does this technology sound familiar? Well it should, it's the same means cellphones use to detect when the caller is holding their phone to their ear.

  • Temperature Data Loggers

    Monarch Instrument

    The Track-It™ Temperature Data Logger is a battery powered stand alone compact data logger that records up to 64,000 samples of temperature data. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.

  • UltraCMOS SP12T RF Switch

    PE42512 - pSemi Corp.

    The PE42512 is a HaRP™ technology-enhanced absorptive SP12T RF switch that supports a frequency range from 9 kHz to 8 GHz. An external VSS pin is available for bypassing the internal negative voltage generator in order for the PE42512 to deliver spur-free performance. It delivers high isolation, low insertion loss and fast switching time, making this device ideal for filter bank switching and RF signal routing in test and measurement (T&M) and wireless applications up to 8 GHz. No blocking capacitors are required if DC voltage is not present on the RF ports.

  • UltraCMOS SP6T RF Switch

    PE42562 - pSemi Corp.

    The PE42562 is a HaRP™ technology-enhanced absorptive SP6T RF switch that supports a frequency range from 9 kHz to 8 GHz. An external VSS pin is available for bypassing the internal negative voltage generator in order for the PE42562 to deliver spur-free performance. It delivers high isolation, low insertion loss and fast switching time, making this device ideal for filter bank switching and RF signal routing in test and measurement (T&M) and wireless applications up to 8 GHz. No blocking capacitors are required if DC voltage is not present on the RF ports.

  • UltraCMOS SP8T RF Switch

    PE42582 - pSemi Corp.

    The PE42582 is a HaRP™ technology-enhanced absorptive SP8T RF switch that supports a frequency range from 9 kHz to 8 GHz. An external VSS pin is available for bypassing the internal negative voltage generator in order for the PE42582 to deliver spur-free performance. It delivers high isolation, low insertion loss and fast switching time, making this device ideal for filter bank switching and RF signal routing in test and measurement (T&M) and wireless applications up to 8 GHz. No blocking capacitors are required if DC voltage is not present on the RF ports.

  • USB to I2C Adapter

    Model JI-300 - Jupiter Instruments

    The JI-300 is a versatile, easy to use PC hosted adapter used to drive I2C communicationsto/from a target device. The desktop unit can be configured to interface a variety of I2Cnetworks. Bus parameters such as clock frequency, duty-cycle, setup and hold times, busvoltage, and pull-up resistor values can be varied. JI-300''s diagnostic features including"excessive clock-stretch", "bus-not-free", and "bus contention" monitoring, as well as statusreporting at the conclusion of each message transaction simplifies I2C trouble-shooting. AWindows software application manages the setup and control of the instrument.Communications and unit power is provided via a USB 2.0 connection.

  • Verification and Validation with SimScale

    SimScale

    SimScale strives to deliver a complete CAE platform to its users, which they can fully trust. In order to meet their expectations, SimScale continues to verify and validate all major features as they are added over time. By verification, SimScale ensures that the problem in hand was conducted properly and by validation, it takes it to the next step to ensure that the results reflect the reality. On a regular basis, multiple validations are performed whose results are compared either to analytical or to experimental data. This page highlights some of the projects performed to validate the features of fluid, structural, thermal and thermomechanical simulation solvers.

  • Dual Display Digital Pressure Sensor [For Gas]

    DP-100L - Panasonic Industrial Devices Sales Company of America

    Panasonic’s compact DP-100L Pressure Sensor with IO-Link features an improved digital display that offers increased clarity and a wider viewing angle. Thanks to a redesign of its circuitry, the low-power-consumption DP-100L Series requires 14% less power during normal operation and when operating in ECO / FULL mode the display is completely shut off for an increased power savings of up to 50% compared to normal operation. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode.

  • 6GHz Dual Frequency Synthesizer moduleValon

    5009 - Valon Technology, LLC

    The Valon 5009 Dual Frequency Synthesizer module is our latest offering in high frequency synthesizer sources. These frequency synthesizers are perfect in applications that require a spectrally pure and highly stable signal source or timing clock. Our synthesizers have replaced laboratory generators costing many times more in a number of applications. Each module actually contains two independent sources locked to the same internal or external frequency reference or standard. Having two phase coherent sources in the same convenient package opens up a wide variety of test applications and solutions

  • Analyzer for Total Sulfur in Gas Application

    SGA-1000 - Atom Instrument

    The ATOM SGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of refinery process applications.ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM SGA-1000 has the fastest analysis time of any commercially available analyzer allowing user-defined, multiple cycle averaging to improve analyzer performance. The analyzer operating software is both intuitive and user-friendly. In addition, the ATOM SGA -1000 only requires bottled air for normal operation and does not require installation in a shelter.

  • ARINC 429 Test & Simulation Interface for PCI

    PCI-C429 - Avionics Interface Technologies

    4, 8, 16, or 32 Software Programmable Tx/Rx Channels - Programmable High/Low Speed Operation - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection - Data capture filtering, 100% bus recording, and physical bus replay - Rate-oriented Label Transmission - Label Selective Trigger for Capture/FilteringIRIG-B time code encoder/decoder with free-wheeling modeApplication Interface supporting C/C++, C# and VB.NET Development - Device driver support: Windows, Linux (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Auto Loading Durometer

    IMADA, Incorporated

    P2 Auto Durometers maximize the repeatability of hardness tests. The P2 features digital speed control to ensure constant speed during hardness tests. The proprietary flexible coupling ensures perfect contact with test samples. All operation and program functions are controlled using the touch screen LCD panel or remotely using an Ethernet connection. Both automated or manual tests can be performed. Dual timers enable recording of the “creep phenomenon” or tendency of the reading to move back as time elapses from the moment the sensor makes full contact with the sample.

Get Help