Filter Results By:

Products

Applications

Manufacturers

Showing results: 3091 - 3105 of 5253 items found.

  • Ultra Low Level DC Voltage Amplifiers

    EM Electronics

    The EM A10 is a low level amplifier module for sensitive measurements, data collection and systems, where signals below 1 nanovolt may be measured. It is ideal for the input unit for precision voltage measuring systems, requiring voltage sensitivity for measuring low noise and low impedance sources. The noise level of the A10 is equivalent to a perfect resistor of about 20 ohms. When used with a digital voltmeter, steady one nanovolt digits may be displayed, with a response time constant of less than a second. The input voltage stability of the A10 is very high, with the drift around a nanovolt per degree C. The input connectors are made from pure copper. The input impedance is very high, and is time dependent, determined by the loop gain.

  • Satellite Clock

    TCG 02-G - Tekron International Ltd

    The TCG 02-G is a highly accurate, full featured GPS and GLONASS (GNSS) clock. Offering multiple oscillator options, Time Code and Frequency outputs, it fits virtually any timing application. With enhanced cyber security features that support NERC CIP requirements, the TCG 02-G is designed for use in modern day smart grid / smart substations, electricity distribution, transmission, and generation protection. In addition industrial application systems and traditional substations are equally provided for. This master clock synchronizes multiple IEDs (Intelligent Electronic Devices) within a network, including protection relays, synchrophasors, event recording and remote telemetry units to enable accurate time stamping. The TCG 02-G is available as a base unit or with one of three expansion module options.

  • PXI-6683, TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module

    782110-01 - NI

    TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module—The PXI‑6683 timing and synchronization modules synchronize PXI and PXI Express systems using GPS, IEEE 1588, and IRIG‑B to perform synchronous events. The PXI‑6683 can generate events and clock signals at specified synchronized future times and timestamp input events with the synchronized system time. The PXI‑6683 features an onboard temperature-compensated crystal oscillator (TCXO) that can be disciplined to GPS, IEEE 1588, and IRIG‑B for long-term stability. You also can use the PXI‑6683 to route clock signals and triggers with low skew within a PXI chassis or between multiple chassis, providing you a method for synchronizing multiple devices in a PXI system.

  • PXI-6683, TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module

    782109-01 - NI

    TCXO, GPS, IRIG-B, IEEE 1588 PXI Synchronization Module - The PXI‑6683 timing and synchronization modules synchronize PXI and PXI Express systems using GPS, IEEE 1588, and IRIG‑B to perform synchronous events. The PXI‑6683 can generate events and clock signals at specified … synchronized future times and timestamp input events with the synchronized system time. The PXI‑6683 features an onboard temperature-compensated crystal oscillator (TCXO) that can be disciplined to GPS, IEEE 1588, and IRIG‑B for long-term stability. You also can use the PXI‑6683 to route clock signals and triggers with low skew within a PXI chassis or between multiple chassis, providing you a method for synchronizing multiple devices in a PXI system.

  • PXI Source Measure Unit

    NI

    PXI Source Measure Units (SMUs) combine high-precision source and measure capability with features designed to reduce test time and increase flexibility. These features include high channel density for building parallel SMU test systems, deterministic hardware sequencing for minimizing software overhead, and high-speed update and sample rates for quickly changing setpoints and acquiring data. Additionally, the flexible sampling rate and streaming capability of PXI SMUs allows you to use the instrument as a digitizer to capture transient behavior, and the digital control loop gives you the ability to adjust the transient response of the instrument. The ability to change the transient behavior of the SMU, called SourceAdapt, reduces SMU settling time and minimizes overshoot and oscillations, even with highly capacitive loads.

  • Test Software

    Powerstar - Intepro Systems

    What separates Intepro from all its competitors is our software, PowerStar. A hardware independent testing software, PowerStar combines LabVIEW-like test flexibility with a library of more than 100 standard drag and drop test routines that cuts development of test programs to a fraction of the time of our competitors.

  • Reactive Energy Regulator

    MASTER - Lifasa - International Capacitors, SA

    It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.

  • Mini OTDR

    FiberPal OT-8800 - Radiantech, Inc.

    OT-8800 series instruments are compact, cost-effective, portable and high dynamic range Mini Optical Time Domain Reflectometer (OTDR). By providing all the measurement functions and performance required for optical fiber construction and maintenance, it is designed for full-range fibre fault detection to solve FTTx, CATV and optical LANs problems

  • Mechanical Testers

    Actron

    Actron’s wide variety of mechanical testers includes specialty tools, compression testers, vacuum pressure gauges and advanced timing lights. All mechanical testers work effectively on most foreign and domestic vehicles, small engines, motorcycles and other recreational vehicles to save you time on inspections and repairs.

  • Current Sensors

    MCx1101 Family - ACEINNA Inc

    Power architects are continually asked to push the boundaries for system efficiency, response time, small size, and low cost in new power system designs. Most modern designs require current sensors to help implement the complicated control, telemetry, and protection circuitry essential in meeting these difficult design goals.

  • Precision Marine Geodetic Systems

    LinkQuest Inc.

    Using leading-edge "Broadband Acoustic Spread Spectrum Technology", accurate sound wave traveling time between LinkQuest's subsea precision transponders and surface station can be measured. When the system is integrated with a Kinematic GPS, motion sensors and a gyro on the surface vessel or undersea vehicle, sub-centimeter acoustic positioning can be achieved.

  • Sound and Vibration Real-Time Analysis System

    DS-3200 series - Ono Sokki

    The DS-3000 series Data Station is a PC-based FFT Analyzer with high functions and high performance. This new FFT Analyzer has two times or more of real-time analysis capability compared to the existing model the DS-2000 series, having the high-speed calculation performance, reliability, and user-friendliness based on our accumulated experience.

  • Smart Home Flowmeter for Water

    F3 - Gentos Measurement & Control Co.

    The F3 is a small compact clamp-on ultrasonic flow meter, based on the Time Comb Technology. The F3 is very easy to install: clamp it on to the pipe, connect it to power and set pipe diameter. The clamp-on design allows the installation in running systems without opening the pipe, providing minimum downtime and maximum availability.

  • Quadrupole Mass Spectrometer for Residual Gas Analysis

    RGA Series - Hiden Analytical Ltd.

    Systems for the examination of components present in a vessel or evolved from a process. HALO RGA – for residual gas analysis. 3F Series RGA – triple filter mass spectrometers for analytical applications. 3F-PIC – pulse ion counting detection for fast event studies. Measures the concentration of gases and vapours in real time.

  • Autocorrelators

    APE GmbH

    From material processing to scientific and medical base research, ultrafast laser systems are used in many areas of their high peak intensity and extremely short pulse width. One relevant area of application is time resolved spectroscopy. The pulse width is a critical factor for the adjustment of these laser systems and the characterization of experiments.

Get Help