Filter Results By:

Products

Applications

Manufacturers

Showing results: 3361 - 3375 of 5411 items found.

  • Alcohol Tester

    Shenzhen Graigar Technology Co.,Ltd.

    Electrochemical (fuel cell) alcohol sensor, Module changeable Test Range: 0.000-2.000mg/l (0.400%B.A.C; 4.000%oB.A.C; 4.000g/l;) Alarming level: Pass level: 0.090mg/L (could be modified) Fail level:0.250mg/L (could be modified) Accuracy: +/-10% Work temperature: -10oC-50oC Work humidity: <95%RH (No Dews) Battery: 2XAA NiMH batteries, rating capacity: 2.1AH Dimension lXbXh: (mm) 250X105X400 Indication manner: mg/l,mg/100ml,g/l ,%BAC,%oBAC optional Coin for single time: 0-15 (For 0, the tester can be tested without coin). Coin diameter: 20mm-28mm Coin thickness: 1.2mm-2.5mm Coins Capacity: about 200 pieces Straw capacity: 200pcs(⊄<=7mm) Breath sampling time: about 5 seconds continuous breath.

  • Digital (1kV up) H.V. Insulation Tester

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • Digital (1kV up) H.V. Insulation Testers

    6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.

  • CoalXPress Frame Grabber

    Xtium-CXP PX8 - Teledyne DALSA

    The Xtium™-CXP is based on the industry standard PCI Express™ Gen 2.0 expansion bus to deliver high speed access to host memory. The Xtium series offers high performance frame grabbers for CameraLink, CameraLink HS and CoaXPress interface standards. The Xtium Series takes full advantage of PCIe Gen 2.0 platform to deliver bandwidth up to 3.4 GB/s using PCIe x8 slots. By enabling maximum sustained throughput and ready-to-use image data, the Xtium series minimizes CPU usage and improves processing times for the host applications. In addition, the Xtium series offers enhanced memory architecture to handle area and line scan, monochrome and color cameras. In addition, the Xtium-CXP series support image acquisition rate of up to 6.25 Gb/s from four input channels.

  • Combination Module: 2 Ch. MIL-STD-1553 & 12 Ch. Discrete I/O

    CM8 - North Atlantic Industries

    The CM8 module is a combination of NAI's MIL-STD-1553B module, FTB, and Enhanced Discrete I/O module, DT4. The CM8 offers twelve channels of discrete I/O and two channels of MIL-STD-1553B communications. The twelve discrete I/O channels are programmable as either input (voltage or contact sensing with programmable, on-module pull-up/pull down current sources), or output (current source, sink, or push-pull) up to 500 mA per channel from an applied, external 3-60 VCC source. The discrete I/O channels also provide additional functionality modes such as Pulse Width Modulation (PWM) output mode and Pattern Generator output mode. The two MIL-STD-1553B communications channels feature a dual, redundant, balanced-line, physical layer; a (differential) network interface; time division multiplexing; half-duplex command/response protocol; and up to 31 remote terminals (devices).

  • DC Gaussmeter

    GM1-ST - Alpha Lab, Inc.

    The Model 1-ST measures strength and polarity of magnetic fields up to 19,999.9 gauss. The sensor can easily fit in a .060 inch (1.5 mm) gap and is at the end of a 100 cm flexible cable. The sensor end can be bent if required for a variety of situations. Place the sensor on a magnet face to measure the field. With a resolution of 0.1 gauss, it can measure any tiny variation from magnet to magnet or it can detect if a given magnet has lost even a little strength. Bend the sensor in to a "L" to measure inside a DC solenoid tube. The 5 digit display requires neither auto nor manual range change, making it easier to use than older style 3 or 4 digit meters. Turn on the meter and immediately begin reading fields (updates 4 times per second). There is no setup required, making this the fastest, easiest gaussmeter available.

  • Dynamic Dilution Calibrator

    Model T700 - Teledyne Advanced Pollution Instrumentation

    The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.

  • Signal Analysis

    Synchronous Accumulation (Order Analysis) - ZETLAB Company

    Order analysis is one of the most convenient and efficient methods for diagnostics and balancing of rotating mechanisms and transmission gears. With an RPM  sensor and a vibration sensor, it is possible to study the time characteristics of gear vibration signals. It is a well-known fact that a signal from a vibration sensor is affected by signals from other sources. To tune out from the disturbing signals, the synchronous signal accumulation method is used. For each shaft rotation, the RPM sensor provides a rotation mark. This signal serves as a triggering strobe for the vibration sensor signal sweeping. The obtained signal sweeps are combined. All the sources of the signals related to the shaft frequency (frequency of rotation) are accumulated and increased in the accumulator linearly proportionally to the N number of rotations. All other signals that are not correlated with the shaft frequency are accumulated proportionally to N1/2 and in case of a greater number of averagings, the useful signal exceeds the interference level.

  • Simulation and Modeling Services for Lightning Protection

    National Technical Systems

    According to the best meteorological estimates, the surface of the earth is struck by lightning approximately 100 times each second, which averages out to about 8 million strikes per day. In addition, the Federal Aviation Administration reports that the average commercial aircraft gets hit by lightning on average about once for every 1,000 hours of flight it completes, which amounts to approximately once a year.With statistics like these, it’s obvious that providing adequate lightning protection to electrical components is crucial — whether that’s onboard an aircraft or as part of a ground-based facility. Fortunately, at NTS, we’ve been helping companies do just that for well over 50 years. Thanks to our lightning simulation and modeling services, companies are able to develop high-quality products that meet with their respective compliance regulations — from military and defense to Airbus and Boeing published standards.

  • Test Pattern Generator Delay & AV Sync Analyzer

    VQDM-100 - VideoQ Inc

    Versatile compact and robust multi-purpose tool for R&D and glass-to-glass QA/QC Instant visual-aural quality estimation plus automatic latency, AV sync and 3D LR sync measurement Multi-channel time-line analysis, including video frames continuity testing 4 Light Sensors with vacuum caps, 4 Audio inputs (standard line levels) 2 channels of AV timing analysis, simultaneous measurements of Video and Audio Latencies Real time multi-channel data acquisition via USB port Unique sophisticated set of static and dynamic test patterns up to 1080p@60fps - see more details in separate VQL page Source of VQDM, VQMA2, and VQMA3 Test Patterns for VideoQ Analyzers Multi-format digital and analog AV outputs: HDMI, YPrPb, S-video, SPDIF, LR analog audio Networkable unit, easy expansion with any external USB storage device: live clips, user content, etc.

  • Test Phone - Professional TS54 Pro

    CZ20154 - Aegis Pty. Ltd.

    The CZ20154 is the top of the range in latest design technology providing voice, data, and video technicians/engineers all the functionality essential in a test set. Buttinskis are now required to deal with modern high speed digital services - something this test phone has been specifically designed for. On top of all the tests performed by the CZ20123, TDR length measurement to 900m is included for the first time on a buttinski. Not only can you measure cable length but you can identify the fault location of an open or a short. Further, tone generation is included as standard providing 5 different search tones and SmartToneR that confirms you have located the correct pair. Never before has this level of features been available in a buttinski. No longer do you need to carry a separate butt set, TDR, toner, and identifier - this buttinski does it all in the one tool !

  • Trace-Level Photometric Ozone Calibrator

    Model T703U - Teledyne Advanced Pollution Instrumentation

    The Model T703U is a microprocessor controlled ozone calibrator for precision gas analyzers. Expanded ozone audit levels have created a need for precise ozone calibration well below the capabilities of standard calibrators. The Model T703U is designed to meet the requirements of ultra-low ozone production.In addition to a high range with similar performance to the Model T703, the Model T703U has the capability to generate ozone in a low range, or "fractional" mode, for producing ozone levels down to 3 ppb, with exceptional accuracy. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperature and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703U, covering time periods up to a year.

  • Transformer Winding Resistance Meters

    RMO TT Series - Amperis sl

    The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.

  • Quality Assurance Testing

    National Technical Systems

    During difficult economic times, one of the first things that seems to get cut back is the quality assurance testing. Although quality assurance is often listed in the unimportant category, it can make a huge impact in your product and your company’s overall revenue and success. The fewer bugs your product ships with, the more your savings. In fact, the cost of fixing anomalies during the design and implementation phase of your development will be less than a quarter of what it will cost once your product has been released. It’s not the job of your customers to identify and test your products for you – unless you’d really like to alienate them and lose their future business. All it takes is one other vendor with a more stable, better designed product to cause your market share to drop like a rock (see WordPerfect vs. Word).

  • Smart Sockets

    Ironwood Electronics

    Ironwood Electronics extended its high performance socket product line with smart features. Sockets are typically rated for 2K to 500K cycles. How do we know if the sockets are used for 100K or 200K insertions? Solution is electronic chip insertion counter. Our sockets can be integrated with electronics counter into the compression mechanism of the socket lid. A push button is exposed on the compression plate. Every time a chip is compressed, push button is actuated which in turn activates the electronic circuitry inside the lid. These activations are counted by the counter IC and displayed in LCD. Let’s say a contact element is rated for 2K insertions. After 2K insertions, this contact element will be replaced by new contact element. Now, the counter has to start the counting from the beginning. To achieve this function, a reset option is included in the electronics circuitry. When reset is actuated, LCD display will go to “0”.

Get Help