Showing results: 3511 - 3525 of 5411 items found.
-
11022/11025 -
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
Talon RTR 2755 -
Pentek, Inc.
- Designed to operate under conditions of shock and vibration- Records gigabit, 10-gigabit or 40-gigabit Ethernet streams- Removable shock- and vibration-resistant SSDs perform well in vehicles, ships and aircraft- TCP and UDP protocols- Copper or optical interfaces- Aggregate recording rates to 4.0 GB/sec- 4U short 19-inch rugged rackmount PC server chassis- Windows® Server 2016 workstation with high-performance Intel® Core™ i7 processor- Up to 122 terabytes of storage to NTFS RAID solid state disk array- Multiple RAID levels of 0, 1, 5, and 6- SystemFlow® GUI with Signal Viewer analysis tool- C-callable API for integration of recorder into applications- File headers include time stamping and recording parameters- Optional GPS time and position stamping- Optional 1836 VDC power supply
-
APCI-3501-8 -
TEAM SOLUTIONS, INC.
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
PXI-C1553 -
Avionics Interface Technologies
Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Time Synchronization to PXI 10MHz reference clock - Real-Time recording and physical bus replay - PXI trigger generation on 1553 bus events - Initiate BC, RT Simulation and BM Capture on PXI Triggers - Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
Exponential Power
Exponential Power introduced the first digital battery hydrometer to the U.S. stationary battery market in 1988. For over 30 years, Exponential Power has sold and serviced thousands of hydrometers and continues to provide the newest technologies in battery maintenance equipment today. Hydrometers (density meters) measure the specific gravity of a battery’s electrolyte. Based on the specific gravity, the user can determine the state of charge of the battery. Retaining these hydrometer readings and data over time is recommended by IEEE as part of any Battery Maintenance Program. Digital hydrometers are commonly used in utilities, telecommunications, industrial, food and beverage, petrochemical and other applications. In contrast to the old bulb-style hydrometers of the past, our digital hydrometers provide accurate recording, storage and transfer of battery data to a PC -- eliminating hours of hand recording and entering data. As a result, time spent on battery maintenance is reduced significantly.
-
imc Test & Measurement GmbH
Electric drives such as DC and EC motors are more and more extensively deployed in the automotive industry. At the same time there is an increasing requirement for a 100% analysis of motors for fault detection and error analysis as well as statistics on quality, without increasing production cycles times. The model-based Parameter Identification method (PI method) from imc allows testing to be performed under load, yet without an “explicit” separate load machine. Instead, the motor is loaded dynamically by exploiting its own inherent inertia. This allows motor parameters such as resistance, inductivity and friction to be determined within a few seconds. A mathematical model and its parameters reflect motor behaviour in its completeness and make it possible to monitor motor production based on limit values and trend statistics. The identified parameters of the model equation can then be used to calculate derived key performance indicators of the motor characteristic curve.
-
Wewon Environmental Chambers Co, Ltd.
These steam aging chamber applied for the testing of sealing property for multi-layer circuit board, IC sealing package, LCD screen, LED, semi-conductor, magnetic materials, NdFeB, rare earths and magnet iron, in which the resistance to pressure and air tightness for above mentioned products can be tested out. ● Overall of the steam aging tester made of stainless steel SUS # 304HL, simple operation settings. Microcomputer digital LED control with time planning function , the maximum set 9,990 Mins. ● Parts, connectors, passive components , semiconductors oxidation test pin high temperature and humidity. ● Metal pin soldering test accelerated aging test. Multiple overtemperature protection / water cut heating and other safety devices. ● The touch- PID + SSR temperature controller, timer function while a time , set the 9990 maximum fractional unlimited.
-
Linkam Scientific Instruments
New uncluttered and intuitive user interfaceLive display of current status for easy monitoringFull control of heating and cooling rate, limit and hold time of up to 100 rampsRow by Row control of Vacuum, Humidity, Tensile Force and Shear modes controllable and synchronised with TemperatureParameters of connected Linkam sensors displayed and stored - e.g. Vacuum, Humidity, Force, XY position and Pressure (dependent on connected stage type)Real Time chart of temperature and other measured parametersTrigger I/O for synchronisation with other equipmentTriggers recorded and plotted row by rowAutomatic setup of controls and parameter limits based on stage type connectedFull five point temperature calibrationUSB 2.0 to T96 and CSS450 ControllersOptional modules including Linkam Imaging Systems with high performance camerasIncludes .NET Components for easy integration into 3rd party applications e.g. LabViewNative 64 bit application
-
ACMAS Technologies Pvt. Ltd.
The extremely accelerated stress environment is defined by high temperature, high humidity and high pressure. WEIBER provides humidity resistance evaluation test for electronics components through customized Extremely Accelerated Stress Test Chamber. This chamber provides high performance test in minimal amount of time according to international IEC 60068-2-66 standard. This chamber also known as Accelerated Stress Test Chamber, Halt and Hass Test Chamber, Halt Test Chamber and Hass Test Chamber.This chamber reduces the time taken for humidity testing in electronic components. 2 types of tests saturated and unsaturated extremely accelerated stress test can be performed. In saturated test the temperature is maintained at 1210C at 100%RH, and for unsaturated temperature of 110, 120, 1300C is maintained at 85%RH. Normally for electronic components unsaturated type test is done.
-
OpenStand -
Prior Scientific Inc.
Whether developing new automation techniques and software or developing new imaging methods, you can quickly find that you need a microscope system tailored to your application and business needs. Prior Scientific has developed OpenStand® to offer a working platform to build OEM solutions and one-off customizations with excellent value for money and reduced development time.
-
Part No. InP1012-20 -
Teledyne Defense Electronics Relays & Coax Switch
Non-terminated SPDT Indium Phosphide Active RF Switch • 3mm x 3mm x 1mm package size • 100ns switching time• Monolithic solid-state switch with no mechanical wear• Flip-chip packaging provides shock & vibration resistance• ENEPIG surface finish for solder bonding• Low loss package with organic overmold• Test board with K-connectors can be providedDC-20GHz
-
Part No. InP1012-14 -
Teledyne Defense Electronics Relays & Coax Switch
Non-terminated SPDT Indium Phosphide Active RF Switch • 3mm x 3mm x 1mm package size • 100ns switching time• Monolithic solid-state switch with no mechanical wear• Flip-chip packaging provides shock & vibration resistance• ENEPIG surface finish for solder bonding• Low loss package with organic overmold• Test board with K-connectors can be providedDC-14GHz
-
Part No. InP1012-30 -
Teledyne Defense Electronics Relays & Coax Switch
Non-terminated SPDT Indium Phosphide Active RF Switch • 3mm x 3mm x 1mm package size • 100ns switching time• Monolithic solid-state switch with no mechanical wear• Flip-chip packaging provides shock & vibration resistance• ENEPIG surface finish for solder bonding• Low loss package with organic overmold• Test board with K-connectors can be providedDC-30GHz
-
HORIBA, Ltd.
Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.
-
XRA-31 -
Excentis
Fast DOCSIS® 3.1 testing and communication troubleshooting is a must to ensure your network is performing the way it should. The key to easy, lighting-fast analysis? Our XRA-31 real-time DOCSIS protocol analyzer. Featuring an exceptionally intuitive GUI, the XRA-31 makes packet capture and analysis a smooth, quick, and pleasant experience – to help you pinpoint issues in no time.