  • High Frequency Current Transformer Clamps

    HFCT-20HD & HFCT-60HD™ - ndb Technologies Inc.

    The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.

  • Transformer Short Circuit Impedance Tester

    JYW6300 - Kingrun Instrument Co., Ltd.

    This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Advanced Series - IBEKO Power AB

    TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Transformer Rated And Self-Contained Training Bench

    Model 8803A - Powermetrix Systems

    The PowerMaster® 8803A Transformer Rated and Self-Contained Training Bench uses an integrated Windows-based touchscreen interface to select and modify a simulated error scenario while located at the bench. This display is mounted on an articulating arm to maximize bench space and enable line-of-sight while standing.

  • Automatic Transformer Turns Ratio Meter

    ATRI-3 - UMA Electronics Enterprises

    Range: 3.00 to 200.0 Accuracy : class 0.1 Ideal for tranformer and motor winding ratio measurement Auxilliary Power: 230V +/- 20% Measures and displays Transformer Turns Ratio by using voltage ratio method. Applying Test Voltage to the Low Voltage winding of a transformer and accurately measures the resulting voltage from the High Voltage winding. As per ANSI/IEEE C57.12.90 Standard Accessories: 10 meter long wire for three phase connection on LT and HT sides. Dimension: 131(H) by 280(W) by 230(depth) Excitation : 1.8V , 150.0Hz, sine wave. Max.500mA Fully Automated measurement of Turns Ratio, Excitation current, LT voltage, HT Voltage and polarity Three Phase Connection enables faster testing Test voltage is applied by 'PUSH to ON' switch, thus allowing safety of personnel during connection/disconnection (Optional) Data can be saved in memory card

  • Linear Variable Differential Transformers (LVDTs)

    Monitran Ltd.

    Whilst there are several ways to measure displacement, the Linear Variable Differential Transformer (LVDT) remains a popular transducer in most industrial applications. LVDTs initially were used as a means of taking dimensional readings in laboratories. They gained popularity in a wide variety of industrial monitoring and control applications, and whilst an LVDT is used to measure displacement the technology can be employed within other transducer types.

  • Gas Filled Hv Test Transformer

    YDQW-50KVA/250KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Inflatable High Voltage Testing Transformer

    GTU-250KVA/500KV - Wuhan Sangao Electrical Test Installations Limit Co.

    SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Current And Voltage Transformer Test Set

    iCT1 - Altanova Group

    iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.

  • Power Transformer Automatic Test Device

    XD71 - Hangzhou Xihu Electronic Institute

    The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.

  • Mini Automatic Transformer Observation System

    mini-ATOS - Raytech AG

    The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.

  • Automatic Instrument Transformer Test Set

    Eltel Industries

    *ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus

  • Low Frequency RF Impendence Transformers

    T&C Power Conversion

    0 kHz to 3 MHz 100W - 4000W 1 input, up to 7 outputs Step-Up / Step-Down Transformers Impedance matching outputs from 1.2 Ohms to 2500 Ohms Compact Design Compatible with T&C''s Class A 10 kHz - 20 MHz LF Generators & Amps Compatible with Class B 20 kHz - 6 MHz LF Generators & Amps