Showing results: 631 - 645 of 1022 items found.
-
Soken Electric Co. Ltd
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
Suzhou 3ctest Electronic Co.,Ltd.
PFS single phase power fail simulator simulates voltage dip, interruption and variation which are caused by power grid and transformer devices due to malfunction or sudden large change of load. It is required to test this kind of phenomena to check whether electronic and electrical device can sustain safety operating condition.
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
SS310 -
Sanshine Electronis Co., Ltd.
Turn ratio meter is a reliable test instrument used for product inspection and sample analysis in the manufacture of transformer, radio and TV set or relative scientific research units.
-
MG-III -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to determine the dissipation factor (Tan Delta), capacitance and resistance of transformer oil and other liquids. Relative dielectric constant and volume resistivity are calculated automatically and displayed.
-
72-9405 -
Tenma
Tests the insulation integrity of wires, arrestors, transformers, motors, and other electrical devices. Digital display for easy reading. Battery operated device works with the press of a button.
-
doblePRIME Delphi -
Doble Engineering
The doblePRIME Delphi is a dissolved gas analysis (DGA) monitor that helps you track transformer health by providing early warning signs of problems such as overheating, insulation degradation or mechanical movement within the transformer.The doblePRIME Delphi provides this valuable information in real time, second by second, through analysis of the insulating oil.
-
HT7051 -
HT Italia Srl
HT7051 has been developed to measure insulation resistance with test voltage programmable up to 5kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, electric cables, electric boards, generic devices, etc.) within BT.
-
C Series -
Titan Tool Supply, Inc.
C Series small-diameter borescopes are designed for general use in inspection areas with diameters as small as 0.40" (10.2mm). 6 models cover a wide range of working lengths from 6" to 60" (152.4mm to 1524mm). Standard models include a wall-plug transformer. An optional flashlight adapter allows for in-field illumination and use.
-
Supreme Instrument Laboratories
Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.
-
Columbia Research Laboratories
The Columbia Model LMT-50 is a unitized rugged package consisting of tandem linear variable differential transformers (LVDT's) with probe assembly. The LMT-50 is designed so that the likelihood of a single failure affecting both output signals is extremely improbable. The model LMT-50 offers flight proven performance, even in the most severe environments.
-
TE30 Lite -
Calmet Smart Calibration Devices
Electricity meters tester class 0.02%. Three phase tester of current transformers and analyser of power network quality. It makes possible electricity meters testing on the site or in the laboratory.
-
Chongqing Assen Power Equipment Co., Ltd
ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.
-
XMC-1553-2-IO -
ALPHI Technology Corporation
The XMC-1553-2-IO-2 uses a DDC® Total-ACE® communication device as its 1553 bus controller, or as a remote terminal with concurrent bus monitor terminal. Dual controller has a dual redundant channel with built in transceivers and transformer. The controller has the capability to emulate up to 31 RT addresses simultaneously.
-
KH23101 -
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.