SR25 -
Computer Conversions Corporation
The SR Series are miniature, low cost AC reference generators designed to supply 26 or 115 volt excitation to synchros or resolvers in military and industrial control applications. They accept +/-15V DC and provide up to 5VA of transformer isolated output power. These converters are packaged in PC card mounting modules 2.6”x3.1”x1”H.
-
BATLV1600 -
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of power factor in low voltage instalations. These equipments are supplied completely assembled and ready for use: it is only necessary to connect it to the mains with cablesof adequate cross section, and to supply the operation signal from suitable current transformer. FML capacitors and swichgear inside metal cabinet. Floor mounting.
-
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
KVZG -
KV Hipot Power Test Equipment Co.,Ltd
DC Hipot Tester is applied to measure output voltage and leakage current for zinc oxide arresters, magnetic blowing arresters, power cables, generators, transformers, circuit breakers and other equipment.
-
PeakTech Prüf- und Messtechnik GmbH
Measuring device in a splash-proof hard case for professional field service use, e.g. for resistance measurement on motor coils, generators and transformers or for continuity testing on ring bus systems in industrial plants.
-
Shanghai Aoboor Electric Co., Ltd.
A CT lowers the current signals for measurement purposes, while a PT lowers high voltage values into lower ones. The transformers are designed to measure whether power systems are both accurate and safe.
-
SCAR 10 -
Altanova Group
This MOV- Metal Oxide Varistor test system is the perfect device to perform analysis and diagnostics on metal oxide arrestors. It is supplied with a special current clip-on transformer designed for the measurement of current leakage.
-
SS107A -
Sanshine Electronis Co., Ltd.
The magnetic torrid ring core winding coil turns tester (SS107A) adopts the high speed center microprocessing unit circuits and precise measurement A/D circuits. This coil turns tester is used to count the coil turns of various torrid core winding coils. Like as: torrid core inductors, torrid core transformers, torrid core sensors, wate meter sensors, torrid current transformers, torrid core choke coils, etc. The tone tester is named magnetic ring core coil turn tester also.
-
ESU-2050 -
BC Group International Inc.
The BC Biomedical ESU-2050 ESU Analyzer is the first instrument of its kind on the market. Designed through extensive collaboration with several of the world's leading electrosurgery generator manufacturers. It is the only ESU Analyzer on today's market with a 1% reading level of accuracy. Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer.
-
Finna Sensors
PC-Based laboratory/production Moisture Analyzer connects through the RS-232 Serial Port. For nuts, granules, powders, pellets, chips or flakes. Complete with:– MCPC-RS Test Chamber– Windows PC-Based Software– Two Sample Cups– Dial Thermometer– Standard Block– RS-232 Cable (10 Feet)– USB to RS232 Adapter– Operating Instructions Manual– 115VAC/60HZ Wall Transformer
-
PQM-700 -
Sonel S.A.
*power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V, with particular emphasis on measurements at low voltage poles, due to the ease of connection,*has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits,built-in real-time clock.
-
HVA28 -
HV Diagnostics Inc.
The HVA28 is the smallest, lightest VLF/DC test instrument on the market. It is about as small as you can make it! Do not let its compact size lead you to believe this unit is lacking in power. The instrument can test up to 100,000ft/30kms of cable (at reduced voltage and frequency). In addition to cables, this unit can test vacuum bottles, transformers, motors / generators, cable sheath/shields, etc.
-
NEO TELE-TRONIX PVT. LTD
We are highly experienced in manufacturing and exporting Induced Over Voltage/DFDV Test Set. It is widely used in electrical and power sector to test different types of transformers. Our range includes different models of testing set to meet clients' diverse requirements. Manufactured in accordance with industry standards, this Induced Over Voltage/DFDV Test Set is offered to clients at competitive price.
-
41-670-101-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
41-670-103-AABBCC -
Pickering Interfaces Ltd.
The 41/43-670-103 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.