Showing results: 751 - 765 of 1022 items found.
-
VLF -
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Programmable micro-controller• Advanced digital frequency technology• Built-in printer• Portable• AC HIPOT testing of cables and electrical apparatus is now easier than before• UDEY VLF testers are suitable for testing cables, transformers, switchgear, rotating machinery, & other electrical apparatus.
-
Weshine Electric Manufacturing Co., Ltd
This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
DC1000A -
Voltech
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
eDAQ-1553 -
Avionics Interface Technologies
One or two dual redundant MIL-STD-1553 bus interfaces - Transformer and Direct bus coupling supported - Two 10/100/1000 Mbit/s Ethernet LAN Interfaces - Streams MIL-STD-1553 bus data in standard IRIG 106 Chapter 10 format. - Compatible with 3rd party recorders and telemetry tools - All captured MIL-STD-1553 bus data provided with timestamps - Full error injection & detection capabilities - Works with AIT’s Flight Simulyzer™ GUI Analyzer/Simulator software
-
FO-1553 -
Avionics Interface Technologies
Extends MIL-STD-1553 bus access to over 1 mile for remote access - Dual redundant, single and dual stream options available - Both Transformer and Direct coupling modes supported - Uses fiber optic 1.0625 Gbps data rates for low latency over long distances - Optical signaling is not affected by electrical noise and interference - Simple and easy to use solution, no software setup or configuration required - Ideal for applications where test equipment is separated from UUT
-
Weshine Electric Manufacturing Co., Ltd
1. This instrument can be widely used in equipment maintenance of substations and power plants, and to measure insulation resistance, absorption ratio and polarization index of high-voltage electrical equipment such as transformers, reactors, capacitors, and circuit breakers. The leakage current of the low-voltage arrester of the power distribution cabinet is automatically tested.
-
OMICRON electronics
The Primary Test Manager™ (PTM) software supports you during diagnostic testing, condition assessment and data management of medium- and high-voltage assets, such as circuit breakers, rotating machines, grounding systems, instrument and power transformers as well as bushings and on-load tap changers (OLTC).
-
MD 5060x -
Scope T&M Pvt, Ltd.
The Megabras MD-5060x is a smart, microprocessor-controlled, 5kV insulation tester and analyzer. Besides the conventional measurement of insulation resistances up to 5 TW, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.
-
Teledyne LeCroy
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
TRT Standard Series -
IBEKO Power AB
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
LS-96 -
Standard Electric Works Co., Ltd
● For ranges higher than 20A DC, use external shunt with a 50mV DC Ammeter.● For ranges higher than 300V DC, use external Volt Divider with a 1mA Voltmeter.● For ranges higher than 5A AC, use external Current Transformer with a 5A AC Ammeter. ● For ranges higher than 600V AC, use external Potential Transformer with a 150V AC Voltmeter.● Full Scale Deflection : 250° ● Accuracy : Class 1.5● Composition : Glass window, ABS resin frame and case, PC glass fiber base mounting fittings included.● Color : Black base and frame, white scale plate and meter body.● Pointer : Stick shape in black color.
-
TA-241 -
Tech-Aid Products
AZ-241 Adapter Panel is designed to meet manufacturer's requirements. This panel will allow by the book testing of the air data computer when interfaced with the main air data test fixture. The Scott-T transformer is optional or can be customer supplied. Without the Scott-T your API can read the altimeter resolver directly.
-
SD -
Computer Conversions Corporation
This unique series of Synchro to DC Converters makes use of advanced digital circuitry techniques to accomplish high speed conversion with extreme accuracy. Transformer isolation as well as balanced line-to-line input impedance is provided for superior and trouble-free system performance, regardless of the input synchro used.
-
ST-600 -
Standard Electric Works Co., Ltd
● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.
-
MD-5060x -
MEGABRAS srl
The Megabras MD-5060x is a smart, microprocessor-controlled, 5 kV insulation tester. Besides the conventional measurement of insulation resistances up to 5 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.