Filter Results By:

Products

Applications

Manufacturers

Transformers

reduce or increase AC voltage.

See Also: Transformer Test, Dissipation Factor


Showing results: 856 - 870 of 1022 items found.

  • Analysis via Fourier Transform Infrared Spectroscopy (FTIR)

    National Technical Systems

    Fourier Transform Infrared Spectroscopy (FTIR) is a standard technique used in the identification of contaminating materials on the surface of printed circuit boards (PCBs) and around the leads of electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) on printed circuit assemblies (PCAs). Additionally, FTIR can be used for “simpler” identifications, such as determining a specific type of plastic or rubber compound.

  • Decade Synchro-Resolver Bridge

    DSRB-5CDA-4 - TEGAM Inc.

    Model DSRB-5CDA-4, 400Hz, Decade Synchro Resolver Bridge combines the functions of a decade synchro bridge and a decade resolver bridge into a single unit. A front panel switch changes the unit from one mode of operation to the other. The units are designed for testing control transmitters, differentials (rotors), and torques transmitters as components or for simulating an incremental control transformer in a servo loop.

  • AC Clamp Meter

    ST-2600 - Standard Electric Works Co., Ltd

    ● Full auto range for V.A and Ω functions. ● Data hold function freezes the reading in dimly lit or hard to reach places. ● Low battery indication. ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.

  • AC/DC Clamp Meter

    3810 CL - Standard Electric Works Co., Ltd

    ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.

  • AC/DC Clamp Meter

    3800 CL - Standard Electric Works Co., Ltd

    ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.

  • Leakage Current Monitor

    LCM500 - Doble Engineering

    The Doble LCM500 Leakage Current Monitor can measure condition while a surge arrester is still in service, measuring the quality of the metal oxide blocks and helping manage the risk of failure.A surge arrester may be inexpensive, but it has an important role in protecting your transformers.With the LCM500, it takes less than 15 minutes to establish that your surge arresters are healthy and the transformer is still protected.

  • Heavy Copper PCB

    VictoryPCB

    Your product descrVictory is a professional Advanced Circuit Manufacturer, We provide 3OZ ~ 6OZ Heavy Copper PCB.Heavy Copper PCB are generally used for high power distribution, heat dissipation, planar transformers, and power convertors. We can make up to 6oz Heavy Copper PCB.iption goes here.Monthy Capability: 3500 Sq M/MonthLayer: 4 LayersMaterial: FR4 TG170Dimension: 350.56mm*580mmFinished board thickness: 2.3mmOuter layer Finished copper thickness: 6ozInner layer base copper thickness: 6ozMin Trace Width/Space: 14milMin hole size: 0.2mmMin hole wall copper: ≥25UMSoldermask Color: Gloss BlackSilkscreen Color: WhiteSurface finishing: HALApplication field: Communication Field

  • MIL-STD-1553 PC/104+ Interface Module

    PC104p-1553 - Avionics Interface Technologies

    Dual redundant, single or dual stream configurations - Transformer & Direct Bus Coupling - Concurrent Bus Controller, 31 Remote Terminals, & Bus Monitor operation - Full error injection and detection - Multi-level trigger for capture and filtering - IRIG-B time code encoder/decoder - Four high voltage (up to 30V) programmable DIO lines - Four trigger LVTTL Trigger I/O lines (2 input / 2 output) - ANSI Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, & VxWorks (others on request) - Conformal coating available - Designed for extended temperature operations - PC/104+ specification v2.2 compliant

  • CT/VT Test System

    Eltel Industries

    Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.

  • Primary Current Injection Testers

    Hilkar

    Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.

  • Insulating Oil Dielectric Loss Testing Electrode

    RY1 - Shanghai Launch Electric Co., Ltd.

    RY1 insulating oil dielectric loss testing electrode (also called oil cup) is used to precisely measure dielectric loss(tgδ), relative dielectric constant(εr)and DC resistivity for liquid insulating materials such as cable oil, transformer oil, capacitor oil, etc. The testing electrode is in line with IEC standards in structure and principle. It is inter-changeable with TETTEX2903 which is widely used in China.

  • EMF Measurements/EM Measurements/Electromagnetic Radiation

    Holland Shielding Systems B.V.

    Electromagnetic fields cause interference in electronic devices and may affect the health of people close to where the fields are generated. It is important to recognize this at an early stage in a construction process, for instance at a future construction location or while construction is already underway, so that budgets are not exceeded. By means of field-strength measurements one can chart the existing electromagnetic fields and radiation emitted by GSM, UMTS antennas and transformer spaces, to mention a few examples. These measurements can help determine the best location in the new building for rooms where sensitive measurements are to take place, e.g. in hospitals or nano laboratories. And last but not least, field-strength measurements can detect sources of interference and can be part of a scheduled check of existing screened spaces and Faraday cages.

  • MIL-STD-1553 Test & Simulation Interface for PCI

    PCI-C1553 - Avionics Interface Technologies

    Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Real-Time recording and physical bus replay - PCI & PCIx Compatible, 3.3V and 5V OperationApplication interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software

  • Aging and Life Test Rack

    SY2036 - Lisun Electronics Inc.

    SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)

  • Analysis via Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS)

    National Technical Systems

    The use of Scanning Electron Microscopy / Energy Dispersive X-Ray Spectroscopy (SEM/EDS) in the analysis of failure related issues of printed circuit boards (PCBs), assemblies (PCAs), and electronic components (BGA, capacitors, resistors, inductors, connectors, diodes, oscillators, transformers, IC, etc.) is a well-established and accepted protocol. As opposed to or simply in addition to normal optical microscopy, SEM/EDS allows for the “inspection” of areas of interest in a much more informative way.

Get Help