Showing results: 376 - 390 of 1031 items found.
-
-
MG-II -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.
-
Chongqing Assen Power Equipment Co., Ltd
Transformer turns ratio tester is a new type of fully automatic tester that uses modern electronic technology to measure the ratio of single-phase and three-phase transformers, and does not require any manual “zero” balance.
-
Neutronics Manufacturing Co.
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.
-
Wuhan Sangao Electrical Test Installations Limit Co.
PD-free HV Testing Transformer is a high-end testing transformer which firstly marketed in China by our company. The high-light characteristic of the equipment reflects the smallness in size, lighter in weight clean ,oil-free,unnecessary static of field investigation ,longer working life without maintenance and slightness in non-partial-discharge. It is used for the insulators' voltage-resistance testing .
-
AE-150™ -
Technology Products
The is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors' data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors.
-
Carl E. Holmes Company
Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
DY100 -
Neutronics Manufacturing Co.
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
GTU-800KVA/800KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
Meco Instruments Pvt. Ltd.,
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
Osborne Transformer Corp.
Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.
-
Neutronics Manufacturing Co.
Oil Test is an equipment designed to test the dielectric strength of Insulating Oils as per relevant specifications vis. IS 6972. It is a useful equipment for Transformer / Switch Gear manufacturing units. Oil fettering agencies, repair shop and electrical maintenance departments.
-
ATRM PLUS -
Eltel Industries
*Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.
-
OTS-A series -
The Motwane Manufacturing Company
OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.
-
Neutronics Manufacturing Co.
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.