Showing results: 466 - 480 of 1031 items found.
-
TEGAM Inc.
Ratio Standards by Tegam including ratio transformers, synchro-resolver bridge, synchro-resolver standard
-
STCS -
Altanova Group
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
Computer Conversions Corporation
The input is transformer isolated and accuracy applies over the operating temperature range and with +/-10% input amplitude and frequency variations. The operational amplifier outputs are not transformer isolated, and can be driven into external power amplifiers and Scott "T" transformers for 3 wire synchro outputs. A typical application of this series is in a conventional positioning servo system as a complex error processor. The use of the solid state CDX makes possible the design of servo systems that can be digitally programmed by direct computer input to the digital input of the SCDX.
-
T 3000 -
Altanova Group
T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers
-
MCH Instruments Co.,Ltd.
*coil testing for motor and transformer *judge quality by comparing wave difference *LCD display
-
Carl E. Holmes Company
Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.
-
Carl E. Holmes Company
Surge suppressors are used to protecting circuits from transients (sudden, brief increases in voltage). Transients of widely varying magnitudes are caused by such circuit components as motors, coils, magnets, relays, and transformers. They are found in all electrical systems and are notorious for damaging diodes, SCRs, transformers, triacs, and relay contacts.
-
Shanghai Himalayal Co.
Testing object: S current transformer, normal current transformer, voltage transformer● Testing item: ratio error, phase error, impedance, admittance of the transformer, etc● Rated current:5A,1A ( Customized )● Rated voltage: 100V, 100/√3V, 100/3V, 110V, 110/√3V, 110/3V, 120V, 120/√3V, 120/3V, 220V (or other)● Measurement range: ratio error measurement range : 0.0001%-19.99% phase error measurement range : 0.01 ' -900 '● Error minimum resolution:ratio error:0.0001%; phase error:0.01 ' ● Communication function : provide RS232 serial communication port● Measurement accuracy: ±1%● Consumed power: less than 20VA● Dimension :460×380×160 mm● Weight: 12kg
-
6450 -
The Eastern Specialty Company
The TESCO CT/PT Bus-Bar Safety Protector (Catalog No. 6450) has been developed to assist in the safe disconnect of a hot sequenced current transformer. After service is disconnected, the TESCO CT/PT Bus-Bar Safety Protector is slid over the bus-bar of the load side of the transformer and prevents accidental connection and/or arcing.
-
-
-
Langer EMV-Technik GmbH
The field sources and the burst transformer are used to harden the device under test. They are powered by an EFT/burst generator.
-
Guildline Instruments Ltd
High Current DC Transformer provides very accurate DC current measurements up to 3000 A with output current that varies directly with the input current in three ranges. This direct current transformer is designed with an open window to pass a single cable, set of cables, or buss bar that carry the direct current to be measured.
-
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.