Showing results: 586 - 600 of 2473 items found.
-
Extech 407760 -
Extech Instruments Corporation
407760 Sound Level Datalogger can record up to 129,920 records and uses a USB interface for easy setup and data download. The datalogger meets ANSI and IEC 61672 Class 2 standards with a 1.4dB accuracy. Additional features include A and C weighting, Fast/Slow response time, and 2 start methods: programmed (from PC) or manual. Comes complete with software, tripod, USB extension cable, windscreen, and 3.6-Volt Lithium battery.
-
U2053XA -
Keysight Technologies
Your product description goes here.The Keysight U2053XA is a fast, accurate and wide dynamic range 10 MHz – 33 GHz USB average power sensor.
-
780469-01 -
NI
50 MHz Bandwidth, 100 MS/s, 2-Channel, 8-Bit USB Oscilloscope Device - The USB‑5133 low-cost oscilloscope device has two channels that sample up to 100 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes and an instrument driver that includes data streaming and analysis functions. This device is ideal for portable and benchtop applications with fast signals that require flexible measurement configurations and up to 50 MHz of analog bandwidth.
-
779970-02 -
NI
50 MHz Bandwidth, 100 MS/s, 2-Channel, 8-Bit USB Oscilloscope Device - The USB‑5133 low-cost oscilloscope device has two channels that sample up to 100 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes and an instrument driver that includes data streaming and analysis functions. This device is ideal for portable and benchtop applications with fast signals that require flexible measurement configurations and up to 50 MHz of analog bandwidth.
-
779970-01 -
NI
50 MHz Bandwidth, 100 MS/s, 2-Channel, 8-Bit USB Oscilloscope Device - The USB‑5133 low-cost oscilloscope device has two channels that sample up to 100 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes and an instrument driver that includes data streaming and analysis functions. This device is ideal for portable and benchtop applications with fast signals that require flexible measurement configurations and up to 50 MHz of analog bandwidth.
-
AX93299 -
Axiomtek Co., Ltd.
*Specification: 1 x RS-232/422/485, 1 x RS-232, 1 x Audio (Mic-in/Line-in/Line-out), 4 x USB 3.0*Dimension: 118 x 40 mm*Compliant Product: PICO880, PICO500, PICO300
-
AX93292 -
Axiomtek Co., Ltd.
*Specifications: 1 x RS-232/422/485, 1 x RS-232, 4 x USB 2.0, 1 x Audio (MIC-In/Line-out), 1 x Power On, 1 x Reset, 2 x LED*Dimensions: 118 x 29 mm*Compliant products: PICO880, PICO500, PICO300
-
779975-01 -
NI
The USB-6509 is an industrial, bus-powered USB device that can directly drive external digital devices such as solid-state relays (SSRs). You can configure each port for input or output, and no external power supply is … required for outputs. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators. If a computer or application fault occurs, the USB-6509 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
LightSpeed1000™ -
GL Communications Inc.
Voice, data, and video traffic is exploding as smartphones, IP TV, video streaming, and "cloud" based services takeoff. A majority of the backbone transport for these applications continues to be SONET and SDH optical transmission networks. A dominant protocol for IP transport is PoS (Packet over SONET) and another is ATM (Asynchronous Transfer Mode). Both schemes are packet based, with ATM using fixed size packets of 53 bytes called "cells", and PoS using variable packet sizes closely matching to Ethernet frames. GL's LightSpeed1000™ hardware platform (PCIe Card and USB Pod) is capable of OC-3/12 and STM-1/4 wire-speed processing on quad optical ports for functions such as wire-speed recording and wire-speed playback of Unchannelized and Channelized ATM, PoS, and RAW Traffic.
-
USB-1901/1902/1903 -
ADLINK Technology Inc.
The ADLINK USB-1900 series provides a range of USB 2.0-based multi-functional DAQ modules. The USB-1901 and USB-1902 16-bit 250 kS/s USB 2.0-based high-performance DAQ modules allow four different voltage input ranges, while the USB-1903 features additional built-in precision current-tovoltage resistors capable of direct measurement of current signal from 0 to 20 mA. The USB-1900 series is USB bus powered and equipped with removable screw-down terminals for easy device connectivity. The attached multi-functional stand can be used for desktop, rail, or wall mounting. Suitable for mixed-signal tests, laboratory research, and factory automation, the USB-1900 series provide a simple measurement solution at an affordable price.
-
AX12260 -
Axiomtek Co., Ltd.
The ultra low power consumption PC/104+ embedded CPU board, the AX12260, is an entry-level core engine with integrated graphics, standalone capability and flexible I/O options that developers require. With its PC/104+ interface, the AX12260 provides the use of a high speed PCI bus (32-bit) in most embedded applications. By built-in AMX LX800 core logic controller with integrated graphics and inherent ruggedness, it also provides a high reliability environment for users.
-
U2056XA -
Keysight Technologies
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis
-
U2057XA -
Keysight Technologies
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
D9010EMBP -
Keysight Technologies
D9010EMBP includes the following powerful protocol decode and trigger software: PCI Express Gen 1 and Gen 2, USB 1.1, USB 2.0, eUSB2, USB HSIC, USB-PD, 10BASE-T Ethernet, and 100BASE-TX Ethernet.
-
783368-01 -
NI
USB, Analyzer Software Included, IEEE 488 GPIB Instrument Control Device - The GPIB‑USB‑HS+ is an IEEE 488 controller and portable analyzer device for computers with USB slots. You can use this device to integrate an instrument into your system using GPIB as well as to troubleshoot and solve GPIB hardware and software problems. The GPIB‑USB‑HS+ achieves maximum IEEE 488.2 performance. With no GPIB cable required for instrument connection, you can use the Hi‑Speed USB port to control up to 14 programmable GPIB instruments. The improved design allows for size compatibility with almost every instrument, adds analyzer functionality, and reduces the overhead to generate faster turnaround times in your application. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.