Showing results: 91 - 105 of 391 items found.
-
Model T100 -
Teledyne Advanced Pollution Instrumentation
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon 'kicker' and advanced optical design combine to prevent inaccuracies due to interferents.
-
Model 30E -
OAI
The Model 30E Enhanced UV Lightsource is highly efficient and may be utilized in a variety of applications. Light is collected by an ellipsoidal reflector and focused on an integrating/condensing lens array to produce uniform illumination at the exposure plane. This UV light source is available in various beam sizes up to 24 inches square with output spectra ranging from 220 nm to 450 nm, using the appropriate lamp (included). Output power ranges from 200 watts to 5 kilowatts. All OAI UV Lightsources are easily equipped with quick-change filter assemblies, enabling the user to customize the output spectrum with little effort. Optional remote exhaust fans are available.
-
Model 308 -
OAI
Dependable and repeatable, The OAI Model 308 UV Intensity/Power Meter is precise, direct-reading instrument designed to measure UV light intensity. The Model 308 features detachable probes for use in the UVA, UVB and UVC ranges, plus a high speed serial port and is available with an optional software package that facilitates instant data logging of intensity mode, time, wave length, serial number and calibration due date.
-
Model T400 -
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
Model N400 -
Teledyne Advanced Pollution Instrumentation
The Model N400 Ultraviolet (UV) Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air. A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
MRC ltd.
The UV Weather resistance test chamber is the world’s most widely used weathering tester to test types of damages include color change, gloss loss, chalking, cracking, crazing, hazing, blistering, strength loss and oxidation.
-
Lambient Technologies
For the first time, users can simultaneously cure fast-reacting light-cured materials, and gather critical data on cure with dielectric cure monitoring. A bundled offering from Lambient Technologies and Uvitron International offers the industry’s only one-stop solution for UV cure and dielectric analysis.
-
Model 32 -
OAI
This new UV LED lightsource is designed and engineered by the proven lithography experts at OAI. The lightsource delivers a number of unique benefits, the most consequential of which is consistent intensity over an exceptionally long life. The lightsource is highly energy efficient, requires no maintenance or light replacement, and contains no mercury.
-
TF424 -
TESTEX Testing Equipment Systems Ltd.
UV Accelerated Weathering Tester, age tester, to simulate the testing environment of sunlight, rain, and dew to reproduce the effect of sunlight with fluorescent ultraviolet lamps, providing rain and dew with condensing humidity. The aging of the specimens is accelerated by exposing the samples to alternating cycles of light and moisture at a certain temperature.
-
UVProbe -
Shimadzu Corp.
UVProbe is multifunctional, easy-to-use software supplied as standard with Shimadzu UV-VIS Spectrophotometers. The UVProbe is connected to the LabSolutions system, which is known for its capabilities in complying with ER/ES regulations. Enables safe, reliable management of data.Not only can UV data be managed, but the comprehensive management of LC, GC, and FTIR data can also be accomplished.In addition, When combined with CLASS-Agent, it provides powerful support for Part 11 compatibility.
-
Model T102 -
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
UVTOUCH -
SolGel Technologies GmbH
100% touch-screen controlled Dosimetry and datalogging digital signal conversion (CAN bus) Compliant with GLP and LIMS standard Intuitive handling with NIST traceable calibration with customized spectral characteristics UVTOUCH sensor not included
-
UVCorder™ -
Oculus Photonics LLP
The compact unit is designed for viewing scenes in the near-UV waveband in real time on a 3.5-inch LCD display and for acquiring near-UV digital video and stills quickly and easily. Oculus Photonics' ultraviolet camera module (UVM) features enhanced ultraviolet response in the 300-400nm range, with a peak response at 370nm, and excellent rejection of visible and infrared light.
-
LPUVI02… Series -
Delta OHM S.r.L.
The radiometer LPUVI02 measures the global effective irradiance on a flat surface (Watt /m² effective), according to the requirements of the WMO for the measurement of UV-index.
-
SolsTiS ECD-X -
M Squared Lasers
The external cavity doubler SolsTiS ECD-X is an extension for SolsTiS. It extends the range of output wavelengths via frequency doubling in a resonant cavity with optimised conversion efficiency to generate high power output from 350-525 nm with a suite of crystals and a single optics set. Automatic, stable lock to SolsTiS is achieved with Hansch-Couillard locking. ECD-X automatically follows SolsTiS frequency scans to deliver >40 GHz of mode hope free tuning across the doubled wavelengths.