Filter Results By:
Products
Applications
Manufacturers
-
product
DC Power Supply, 35 V, 1 A, 35 W
E36104B
The Keysight E36104B is an accurate, 35 V, 1 A, 35 W compact power supply for your bench or system.
-
product
MODEM ELIMINATOR
The UDC-ME allows two DTE devices (such as routers) to communicate within proximity of each other. The UDC-ME transmits data bi-directionally at clock rates of 1.2k up to 3.072Mbps between DTE devices. The unit is equipped with two interface slots that allow a host of serial interface cards to be utilized. The serial interface cards available are RS-232, RS-422/449, RS-530, X.21, V.35 and HSSI. The Serial Interface cards are interchangeable and may be mixed such as RS-232 to V.35 thus eliminating the need for an interface converter or changing expensive serial cards on a DTE device such as a router.
-
product
Electronic Boards
Computer Gesteuerte Systeme GmbH
The relay board 8AGN is a cost-effective board of the CM series, which is also used in our load modules, for example. It can be mounted on a 35 mm DIN rail. Currents up to 1 A at 30 V are possible. The maximum wire cross-section is 0.5 mm².
-
product
V-Band Low Noise Amplifier 50 to 75 GHz, 35 dB Gain, 5 dB NF
SBL- 5037533550-1515-E1
50 to 75 GHz, 35 dB Gain, 5 dB Noise Figure V Band Low Noise Amplifier for IEEE 802.11.ad WiGig. Model SBL-5037533550-1515-E1 is a low noise amplifier with a typical small signal gain of 35 dB and a nominal noise figure of 5 dB across the frequency range of 50 to 75 GHz. The DC power requirement for the amplifier is +8 VDC/150 mA. The mechanical configuration offers an in-line structure with WR-15 waveguides and UG-385/U flanges.
-
product
E1/Datacom Transmission Analyzer
DTA-BERT
DTA-BERT E1/Datacom Transmission Analyzer can perform E1 transmission performance test (BERT) and status monitoring on data link (V.35, V.24/RS232, RS449, RS530, X.21). Model T can also perform G.703-64K bit error test, PCM31/30 test and Jitter test. Featuring comprehensive functions, easy operation and compact design, DTA-BERT provides total solutions for E1 line analysis and maintenance.
-
product
Serial I/O Boards
Serial Mode Protocols include Asynchronous, Bisync, SDLC, HDLC, IEEE 802.3, Synchronous Telemetry, Simple Clock/Data ("-SYNC" product line), Di-phase and SPI Interface. Transceiver support RS485, RS422 (V.10), RS232 (V.28), RS423, V.35, RS530, as well as other software selectable mixed protocol modes Up to Eight Independent Serial Channels per Board Synchronous Serial Data Rates up to 10 Mbits/sec Asynchronous Serial Data Rates up to 1 Mbits/sec PMC and cPCI rear I/O support Custom Protocols Available
-
product
Multiprotocol Transceivers
Analog Devices’ RS-232/RS-485 multiprotocol transceivers are the only parts in the market that allow protocol switching and allow for switching between half-/full-duplex operation and switching on/off termination resistors, both of which minimize physical user intervention when reconfiguring networks. Features include 3.3 V to 5 V operation, up to ±26 kV ESD, a logic supply pin, and small LFCSP packages. As large-scale computing applications typically require more protocols than the RS-232 and RS-485 protocols found in everyday applications, we support legacy protocols. These include V.28 (RS-232), V.35, RS-449, RS-530, RS-530-A, V.36, or X.21. Software-selectable protocol, cable termination, and data terminal equipment (DTE) or data communications equipment (DCE) configurations all provide convenient flexibility.
-
product
Digital (1kV below) Insulation Tester
2751 IN
Standard Electric Works Co., Ltd
● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.
-
product
32-CH Isolated DIO PCI Cards
PCI-7230/33/34
ADLINK"s PCI-723X series are 32-CH isolated input and/or output cards which provide a 2,500 V optical isolation protection. The wide input range of the PCI-7230 and PCI-7233 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The PCI-7230 and PCI-7234 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automation applications. The PCI-7234P provides current-source output capability. The PCI-7230 and PCI-7233 also provide two interrupt sources on digital input channels. The PCI-7233 also features a change-of-state (COS) function that generates an interrupt when any digital input changes its state.
-
product
32-CH Isolated DIO Card
LPCIe-7230
ADLINK LPCIe-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCIe-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCIe-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCIe-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.
-
product
Low-Profile 16-CH Isolated DI & 16-CH Isolated DO PCI Card
LPCI-7230
ADLINK LPCI-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCI-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCI-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCI-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.
-
product
100W Dual Output Power Supply Two 35V, 1.4A or 60V, 0.8A
E3649A
Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
product
FM Tokenless Transmitter & Receiver
MS 1522
Transmitter and Receiver units are designed to work at 24V DC voltage (nominal) with variation between 19.2 V to 28.8V. The system is designed to work with carrier frequency 1800/2700 Hz and modulated frequency 65Hz/85Hz. For 1800Hz Carrier Frequency RED border is used in Front Panel and for 2700Hz Carrier Frequency BLUE border is used in Front Panel. Maximum power consumed by transmitter and receiver are 1.2W and 8W, respectively. Sense level for receiver is less than –19 dBm and No sense level for receiver is more than –22 dBm with 1mw (0 dBm) transmitter power. The equipment is designed to work satisfactorily with temperature variation from 0°C to 55°C with relative humidity of 95% at 35°C. Suitable test points are provided in the back of the equipment to monitor the necessary parameters.
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.