Filter Results By:
Products
Applications
Manufacturers
VEE
graphical programming environment optimized for instruments.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
Ethernet Controlled Relays And Relay Drivers
*ICS's Ethernet to Relay Interfaces provide the user with a choice of 16 contact closures or 16 relay driver outputs for driving external relays. All of the Ethernet to Relay Interfaces include 8 isolated digital inputs. Available in ICS's Minibox™ or as an OEM board.*All interfaces are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE or with RPC commands from any Linux/Unix or MAC computer. Use ICS's interactive VXI-11 Keyboard program for easy operation from your PC without having to write a program.
-
product
Ethernet Digital Interface
Model 8063
* Provides 48 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes or data strings.* Transparent data transfer mode.* Fully VXI-11 Compliant plus Raw Socket for easy programming with Visual Basic or C, Agilent VEE and LabVIEW.* 1 U high rack mount kit mounts one or two 8063s.* Includes 100-230 VAC Power Adapter with universal plugs.
-
product
Ethernet Parallel Interface
Model 8013
* Provides 128 high-power TTL I/O lines.* Fully VXI-11 Compliant plus Raw Socket for easy programming with Visual Basic or C, Agilent VEE and LabVIEW.* Standard board has a horizontal Ethernet connector and 150-pin Digital IO connector on the component side. * Mates to Relay Driver Boards with 64 or 128 Relay Drivers.* Mates to 115650 Connector Board with 4 flat ribbon headers.
-
product
Ethernet Parallel Interface
Model 8003
* Provides 40 high-power TTL I/O lines.* Fully VXI-11 Compliant plus Raw Socket for easy programming with Visual Basic or C, Agilent VEE and LabVIEW.* Standard board has vertical Ethernet and Digital IO connector on the component side. * Optional Relay Driver board adds 4, 32 or 40 Relay Drivers. • Apply regulated 5 Vdc power through the Digital IO connector.
-
product
Ethernet to GPIB Controller
Model 8065
* Controls GPIB Devices anywhere there is a network or internet connection.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* VXI-11 compliant.* Includes ICS's VXI-11 and VISA keyboard control programs.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver lets you change network settings from any browser.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the GPIB instruments.* 8065 is our original Ethernet to GPIB Controller and recommended for replacement purposes with existing programs. Use the Model 9065 for new applications.
-
product
Ethernet to GPIB Controller
Model 9065
* Controls GPIB Devices anywhere there is a network or internet connection.* No special driver required which eliminates driver problems. * Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Fully VXI-11 compliant. * Includes ICS's VXI-11 and VISA keyboard control programs. Control instruments without a program. * Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver lets you change network settings from any browser.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the GPIB instruments.* Supports GPIB and HP-IB 488.2 complicant instruments.* 9065 is a 2nd generation drop-in replacement for ICS's Model 8065. The Model 9065 is 2x to 4x faster and includes a webserver instrument control page.
-
product
Ethernet to GPIB Instrument Interface
Model 9055
* Adds a VXI-11 compatible Ethernet Interface to a GPIB Instrument* No special driver required which eliminates driver problems. * Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Works with Agilent, NI and Kikisui VISA libraries.* Controllable from MAC OS X/UNIX/LINUX and similar computers with RPC calls.* Fully VXI-11 compliant.* Includes ICS's VXI-11 and VISA keyboard control programs.* Internal webserver lets you change network settings with any browser.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the GPIB instrument.* Upgraded replacement for ICS's Model 8055 with 2x to 4x speed improvement.
-
product
Ethernet to Modbus RTU Interface
Model 9099
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
product
Ethernet To Parallel Digital Interface Boards
ICS's Ethernet Parallel Digital Interface boards provide the user with a wide range of IO signals that can be user configured to match virtually any application. These Ethernet boards are available with high power relay driver boards and with optional firmware designed to simplify switching applications. The 80x3 boards have high-power TTL signals that can sink 48 mA and source 24 mA. Pullup resistors make it easy to interface with CMOS logic and to sense contact closures. User configures data byte direction and polarity. The 80x3 boards are VXI-11 compliant for operation with NI or Agilent VISA, LabVIEW and VEE and support raw socket connections. The new 8113 board is a CMOS close of the 8013 board with user set 3.3 or 5 V logic levels. Pinouts and command set is the same as the 8013 board. The 8113 communicates with TCP/IP(Raw Socket) protocoland and also has a RS-232 Serrial Port. All boards are designed for mounting against the rear panel or inside a chassis and use our Ethernet Wiring Kit for easy connection to a Ethernet Connector on the rear panel.
-
product
GPIB Relay Interfaces
*ICS's GPIB to Relay Interfaces provide the user with a choice of 16 contact closures or 16 relay driver outputs for driving external relays. All of the GPIB to Relay Interfaces include 8 isolated digital inputs. Available in ICS's Minibox™ or as an OEM board.*All interfaces are IEEE-488.2 compliant and use SCPI commands for operation with NI or Agilent VISA, LabVIEW and VEE or any GPIB programming language. Use ICS's interactive GPIB Keyboard program for easy operation from your PC without having to write a program.
-
product
Serial Controlled Relays And Relay Drivers
*ICS's Serial controlled Relay Interfaces provide the user with a choice of 16 contact closures or 16 relay driver outputs for driving external relays. All of the Serial to Relay Interfaces include 8 isolated digital inputs. Available in ICS's Minibox™ or as an OEM board.*All interfaces are IEEE-488.2 compliant and use SCPI commands for operation with NI or Agilent VISA, LabVIEW and VEE or any Serial programming language. Use ICS's interactive Serial Keyboard program for easy operation from your PC without having to write a program.
-
product
USB to GPIB Controller
Model 488-USB2
* Adds GPIB Controller capability to any PC with a USB port.* Fast >1 Mbs transfer rate * Most affordable USB GPIB controller with an industry standard GPIB-32.dll.* 488.2V4 Driver supports 32 and 64-bit versions of Windows XP, Vista, Windows 7, 8 and Windows 10 with a true 64-bit DLL.* Uses industry standard 'ib' and '488.2' command sets.* Works with Agilent, NI and Kikisui VISA libraries.* Program with Visual Basic, C, Agilent VEE, LabVIEW, or MATLAB.* ICS's Explorer auto configures your controller as it finds your instruments.* Use ICS's Explorer to control your instruments without having to write a program.
-
product
Keysight VEE Student 9.32
W4000D
Keysight VEE Student 9.32 is a subset of Keysight VEE Pro 9.32. It is designed for students for better computation, simulation and instrument control in lab and design projects.
-
product
Command Expert
Keysight's Command Expert is no-cost software that provides fast and easy instrument control in many PC application environments. Download Command Expert 2017 Update 2 today! Learn about the new features in Command Expert 2017 Update 2Seamless integration with Excel, VEE, SystemVue, MATLAB, Visual Studio, Python, and LabVIEW Easy to find, use, and view full documentation for SCPI, IVI-C, IVI-COM, and IVI.NET commands Simplifies the process of retrieving measurement data from instruments
-
product
VEE Pro 9.32
Keysight VEE Pro 9.32 is an easy-to-use graphical language environment that provides a quick path to measurement and analysis, replacing VEE Pro 9.3. Designed for easy expansion, flexibility and compatibility with the latest industry standards, Keysight VEE allows seamless operation with hardware and software from Keysight and other manufacturers.
-
product
64 Input USB Modular Digital I/O
U2652A
The Keysight U2652A USB Digital I/O is a cost-effective device with its offering of 64 opto-isolated digital lines. It comes bundled with the Keysight Measurement Manager (AMM) software for quick set up and data logging. Simplifying this further is the command logger function offered in the Keysight Measurement Manager that allows capturing of configuration commands that can be easily converted to snippets of VEE code. Other supported languages are VB, C++, and C#.
-
product
64 Output USB Modular Digital I/O
U2653A
The Keysight U2653A USB Digital I/O is a cost-effective device with its offering of 64 opto-isolated digital lines. It comes bundled with the Keysight Measurement Manager (AMM) software for quick set up and data logging. Simplifying this further is the command logger function offered in the Keysight Measurement Manager that allows capturing of configuration commands that can be easily converted to snippets of VEE code. Other supported languages are VB, C++, and C#.
-
product
32 Input, 32 Output USB Modular Digital I/O
U2651A
The Keysight U2651A USB Digital I/O is a cost-effective device with its offering of 64 opto-isolated digital lines. It comes bundled with the Keysight Measurement Manager (AMM) software for quick set up and data logging. Simplifying this further is the command logger function offered in the Keysight Measurement Manager that allows capturing of configuration commands that can be easily converted to snippets of VEE code. Other supported languages are VB, C++, and C#.