Showing results: 511 - 525 of 589 items found.
-
N9912C -
Keysight Technologies
Select from cable and antenna analyzer (CAT), Vector Network Analyzer (VNA), and/or Spectrum Analyzer with desired maximum frequency. Capture elusive signals with up to 40 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
MT7553 Series -
Maury Microwave Corporation
Noise Parameters are the non-50Ω extensions of Noise Figure, and are an important modeling and model validation tool to understand how a device-undertest’s performance changes as a function of source impedance. Noise Parameter measurements are typically performedusing a Vector Network Analyzer (VNA) to measure the S-Parameters of the DUT, and a Noise Analyzer (either Noise Figure Analyzer NFA or Spectrum Analyzer SA) to measure the noise power of the DUT. Noise parameters are calculated from a combination of knownsource impedances, S-parameters and noise powers.
-
N9915A -
Keysight Technologies
9 GHz max frequency Carry the world's most integrated handheld & micro; W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal
-
N9914A -
Keysight Technologies
6.5 GHz max frequency Carry the world's most integrated handheld RF analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in the same sweep Simultaneously measure all four S-parameters Make accurate spectrum analyzer measurements ( 0.5 dB) without needing warm-up Calibrate simply with QuickCal
-
TFC2.5G -
Huber Signal Processing
The device provides a frequency range of up to 5 GHz and a high spectral purity, a continuous frequency or amplitude sweep, a vector modulator with 80 MHz modulation bandwidth, a fast settling time and a high signal-harmonic ratio. Due to its modular construction, options are available for retrofit. Integrated modulation modes are AM, FM, Pulse and I/Q. An integrated baseband signal generator (for e.g. QAM) is available as option. With this, baseband signals can be uploaded into the devices' memory and converted.
-
NI
PXI FlexRIO Coprocessor Modules feature high-performance FPGAs that add signal processing capability to PXI systems. These modules leverage the latest FPGAs from Xilinx, streaming technologies such as PCI Express, and NI Peer to Peer Streaming for high-bandwidth data communication with other modules over the backplane. When paired with another PXI device, such as a PXI Vector Signal Transceiver, PXI FlexRIO Coprocessor Modules provide the additional FPGA resources required to run complex algorithms in real-time.
-
NI
PXI IF Digitizers offer onboard signal processing (OSP), which enables features such as quadrature digital downconversion (DDC), real digital downconversion, and anti-alias filtering. Models include a high dynamic range front end and a highthroughput PXI Express interface, which allows them to stream IF data to disk for hours at the full sample rate. You can also choose a PXI IF Digitizer that can convert IF signals to I/Q data, so you can use this model as a standalone IF digitizer or as part of a Vector Signal Analyzer.
-
GX5290 -
Terotest Systems Ltd.
The GX5290 Series are a high performance, cost-effective 3U PXI dynamic digital I/O boards offering 32 TTL or LVDS input or output channels with dynamic direction control. The GX5290 Series also supports deep pattern memory by offering 256 MB of on-board vector memory with dynamic per pin direction control and with test rates up to 200 MHz. The single board design supports both master and slave functionality without the use of add-on modules.
-
ETS880 TITAN -
Hilevel Technology, Inc.
*Test rates up to 200MHz (100MHz All Modes) *Clocks up to 400MHz *Two strobes per cycle * High Pin Count: Up to 1,024 logic pins in ONE Chassis *Optionally supports up 4,096 DC pins, or combination of both * Direct Docking precision manipulator *Low Cost *Up to 64Meg test vector depth *Programmable loads and parallel loads *Multiple DC PMU units * Timing On-the-Fly * Mixed Signal Option
-
Elmika
Waveguide cassettes provide easy way for the network analyzer calibration and material properties as dielectric permittivity or (and) magnetic permeability measurements. By changing insertion sections, it is possible to calibrate "Short" and "Thru". Optional cassettes with quarter wave "short" inserters are available. Using this waveguide cassette, it is possible to do vector network analyzer calibration or additional scalar network analyzer calibration. Insertable sample holders supports two measurement methods: the rod in the centre of the waveguide and filled waveguide cross-section.
-
S95551B -
Keysight Technologies
PXI vector network analyzers (VNA) offer the capability to extend the number of ports for your measurements by using additional modules. When multiple modules are used, they are configured for multiport operation. The S95551B adds a multiport analyzer mode that enables full multiport error correction and measurement capabilities. The instruments may be identified as one VNA by the firmware running on an external host PC. At least one VNA instrument connected to your PC must have one S95551B license to maintain N-port capabilities.
-
N9952A -
Keysight Technologies
50 GHz max frequency Carry industry's first 50 GHz handheld W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in a single sweep Simultaneously measure all four S-parameters Make accurate SA measurements ( 0.5 dB) without needing warm-up Easily measure average and pulse power with a USB sensor
-
N9951A -
Keysight Technologies
44 GHz max frequency Carry world's most integrated handheld W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in a single sweep Simultaneously measure all four S-parameters Make accurate SA measurements ( 0.5 dB) without needing warm-up Easily measure average and pulse power with a USB sensor
-
N9950A -
Keysight Technologies
32 GHz max frequency Carry world's most integrated handheld W analyzer: standard model includes cable and antenna analyzer Expand capabilities with optional VNA, spectrum analyzer, built-in power meter, vector voltmeter, and more Save time by measuring DTF and TDR in a single sweep Simultaneously measure all four S-parameters Make accurate SA measurements ( 0.5 dB) without needing warm-up Easily measure average and pulse power with a USB sensor
-
SSC/924 -
Delta Digital Video
The Model SSC/924 Stroke-to-Video Scan Converter converts stroke video from XYZ vector to a standard video format. Stroke video is generated by a variety of random deflection devices, including certain radar and sonar devices, spectrum analyzers, and Heads Up Display (HUD) generators. High Definition, Standard Definition, and VESA video output standards are provided. After conversion, the video can be recorded using standard video recording devices and viewed using low cost, off-the-shelf monitors.