  • [5kV AC/6kV DC] Hipot and Insulation Resistance Tester, Rise/Fall-Time Control Function Equipped

    TOS5300 Series - Kikusui Electronics Corp.

    The "TOS5300 Series" is a series of test instruments used in Hipot (withstanding voltage) tests and insulation resistance tests, two of the four tests regarded as necessary for ensuring the safety of electrical products. With an output of 5 kV/100 mA (AC) and 6 kV/10 mA (DC), the series can be used in Hipot (withstanding voltage) & insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards and the Electrical Appliance and Material Safety Law. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a new low-cost standard model that provides thorough operability, reliability and safety.

  • Basic Quad J-Type Analog Thermocouple Amplifier

    SEN-30103-J0 - Playing With Fusion Inc

    Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.

  • Basic Quad J-Type Analog Thermocouple Amplifier

    SEN-30103-J1 - Playing With Fusion Inc

    Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.

  • Basic Quad K-Type Analog Thermocouple Amplifier

    SEN-30103-K0 - Playing With Fusion Inc

    Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.

  • Basic Quad K-Type Analog Thermocouple Amplifier

    SEN-30103-K1 - Playing With Fusion Inc

    Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2205 - TREK, INC.

    The Trek Model 2205 is a member of Trek’s 2200-series of high-voltage 40 W amplifiers that offesr high performance at an attractive price. It incorporates DC stability, wide bandwidth, well regulated and controlled AC output signals, full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument also stage sinks or sources current into reactive or resistive loads throughout the output voltage range which makes it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Linear Power Supplies Bipolar 4-quadrant, Analog/Digital/Local Control, Ultra Low Ripple/Noise

    BOP Series - Kepco, Inc.

    Kepco's bipolar BOP power supplies are available in 100W, 200W and 400W sizes. For applications requiring higher power, see Kepco's 1KW High Power BOP. For applications requiring higher voltage, Kepco's Series BOP-HV are available in 500V and 1000V models.BOP are high speed power operational amplifiers that can be used to provide dynamically agile voltage for test and simulation. They are not general purpose power supplies. By the nature of the bipolar high speed design, they do not have any energy-storage noise discriminating output capacitors. These power supplies offer ultra low noise and ultra low ripple at the output and are MIL-STD-461 compliant.

  • OTP-Based Test System

    LXinstruments GmbH

    Power electronics assemblies often cannot be tested using conventional technology for their electrical performance. Due to the adaptability of the instrumentation, the OTP concept offers an ideal platform even beyond the space requirements of several control cabinets. In order to achieve high test flexibility with different assemblies, the system was equipped with three-phase AC sources and AC loads as well as a precise three-phase power meter. DC sources and loads with different current and voltage ranges cover the test of frequent DUT operating parameters. Time-dependent voltage or current signals can be stimulated by an arbitrary generator with power amplifier. General measurements such as current, voltage, frequency, resistance can be carried out flexibly at various test points using the matrix concept. An oscilloscope with RF multiplexer is available for high-frequency measurements such as residual ripple, switching processes, etc.

  • Signal Conditioning System

    28000 - Precision Filters, Inc.

    The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2220 - TREK, INC.

    Trek’s Model 2220 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2210 - TREK, INC.

    Trek’s Model 2210 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and auto recovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Converter Of Electrical Quantities

    Metra Blansko a.s.

    The converters are intended for the conversion of electrical quantities DC signal which is either in form of the DC voltage, or the DC forced current. They can be used in connection with indicating pointer instruments, calibrated in units of the measured quantity, or with a recorder or, eventually with a digital instrument. Wide range of possibilities are provided by them, also as sensors for regulation and control porposes in the fields of industrial measurements and, last but not least, as needful components for aquisition of technological enviroment picture applied for evaluating and processing computer systems. The converters are designed for continuous operation. They are designed as independent, built in the plastic casing. Each converter comprises the input circuits for the galvanic separation of the proper measuring circuit and the output amplifier for the output signal conversion to the unified output.

  • Cable Tracer and Phone Tester (2 in 1)

    183 CB - Standard Electric Works Co., Ltd

    Cable Tracer● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset. (Amplifier probe)Phone Tester● Continuity and resistance testing for voltage-free objects.● Check direct and alternating voltages.● Testing capacitors.● Testing diodes.● Power ON/OFF switch.● The indication of the LED lamp and the sound of the buzzer can occur at the same time.● The LED indication for Power ON status.

  • Measurement System for ESD Protection

    SampleProtect - Oxford Instruments plc

    The SampleProtect measurement system is ready to go, and comes complete with Oxford Instruments’ Cryofree bottom loading cryostat – the OptistatDry BLV, Zurich Instruments’ MFLI Lock-in Amplifier, a specially designed ESD break-out box and high quality measurement grade cables. The patent-pending puck style mounting from Oxford Instruments provides safe installation of your samples. The MFLI 500 kHz Lock-in Amplifier (capable of 500 kHz demodulation as standard) with MF-MD multi-demodulator capability brings the benefits of high performance signal processing at low and medium frequencies. The differential voltage and current inputs of the MFLI are optimised for low noise operation and the high oversampling rate ensures an even better signal to noise ratio. Zurich Instruments’ unique LabOne® control software provides a toolset including an integrated oscilloscope, a spectrum analyser, a plotter and a parameter sweeper.

  • *OEM Power Sensors

    mks Ophir

    The OEM “standard” sensors are actually families of existing OEM sensors with typical specifications shown. They can be tailored as needed to fit your specific requirements. In addition to the products described, Ophir has developed hundreds of other OEM solutions. These compact laser power sensors have built-in amplifiers and are easy to install. They contain all the electronics needed including algorithms to increase the sensor's speed of response. Connections to the sensors are simple, with the host providing DC power and the sensor providing a voltage or digital output. Outputs Available: DB15 smart sensor output; Calibrated analog output; RS232; USB; Ehthernet. Simply fill out the Sensor Customization form so we can provide just the right solution for your needs.

Get Help