Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 3331 - 3345 of 6572 items found.

  • Relay Testers

    NF Corp.

    Outputs 100VA single-phase voltage and 180VA single-phase currentEquipped with counter function, output selector, auto sweep function, memory function, DC output for testing, master/slave function, etc.Output frequencies of 50Hz, 60Hz, and 10Hz to 200Hz, using external synchronization or line synchronization (selectable)Equipped with GPIB/RS-232C interfacesWeight: 19.5kg

  • PXI System Monitoring Module

    NI

    The PXI System Monitoring Module can be used with a PXI Chassis to detect and report chassis voltage rail problems, abnormal chassis intake temperature, or a chassis power shuttle fan failure. The PXI System Monitoring Module also includes a relay that can toggle when any of the parameters fall outside the chassis operating specification.

  • DC to 100MHz

    1394A - Ballentine Laboratories, Inc.

    Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.

  • Battery Tester

    all-sun

    s an electronic device intended for testing the state of an electric battery, going from a simple device for testing the charge actually present in the cells and/or its voltage output, to a more comprehensive testing of the battery's condition, namely its capacity for accumulating charge and any possible flaws affecting the battery's performance and security.

  • Solid State Relays for AC Power Switching Applications Requiring High-Rel and High Safety

    Series KA/LA - Teledyne Defense Electronics Relays & Coax Switch

    Series KA/LA solid-state relays are designed for use in AC power switching applications where safety and reliability are primary concerns. They are ideal for resistive and reactive loads with power factors as low as 0.2. Inverse parallel SCRs are configured for zero-​voltage turn on. The relays are available with thermal protection and thermal trip status.MSL 1 Available options include:KA58HF 2Arms, 250Vrms Load; 3.8-32Vdc bias voltage, 250µA CMOS Control;​ includes thermal protection & thermal trip statusLA00HL 2Arms (7.5Arms with heat sink), 250Vrms Load; 3.8-32Vdc bias voltage, 250µA CMOS Control​; LA58HL 2Arms (7.5Arms with heat sink), 250Vrms Load; 3.8-32Vdc bias voltage, 250µA CMOS Control​; includes thermal protection & thermal trip status​

  • 11 Function True RMS Multimeter + NCV

    Extech EX350 - Extech Instruments Corporation

    The EX350 is a professional DMM loaded with advanced features and functions. Low Impedance (LoZ) mode eliminates false readings caused by ghost voltages. Low Pass Filter (LPF)attenuates high frequencies to reduce noise for accurate readings. True RMS provides accurate readings when measuring distorted or noisy waveforms. Built-in Non-Contact AC Voltage Detector quickly checks for the presence of AC Voltage before testing. Features a 4000 count LCD display, data hold, min-max, relative mode, capacitance zero, auto power off, continuity and diode test. This meter will measure AC/DC voltage to 600 V and AC/DC current to 10 amps. Complete with test leads, manual and two AA batteries.

  • High Power Programmable AC Source with Transients

    61510 - Chroma Systems Solutions, Inc.

    Power Rating:61511: 12KVA61512: 18KVAVoltage Range: 0-150V/0-300V / AutoConfigurations with input voltage of 220V or 480VFrequency: DC, 15Hz-1500HzSingle-phase or three-phase output selectableProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage and current limitHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetCapable of delivering power output up to 90KVA by implementing Master-slave parallel operation

  • AC/DC TRMS Insulation Clamp Meter

    CMi210 - Martindale Electric Co. Ltd

    A unique insulation clamp meter for the installation, testing and maintenance of domestic and industrial installations. This high specification clamp meter can perform insulation tests to 6G Ohms with 5 test voltages from 50V to 1000V.

    The clamp provides True RMS measurement of AC current to 1500A and AC voltage to 750V. It will also measure DC current to 2000A and DC voltage to 1000V. The CMi210 has all the same test functions you would expect to find on a high specification multimeter with the added benefit of temperature measurement.

  • Digital Recorder

    HiRES - HIGHVOLT Prüftechnik Dresden GmbH

    The digital recorders HiRES are used to measure, store, and evaluate signals from up to 64 sources synchronously. Depending on the sensors used voltages, currents, temperatures, mechanical movements and various other signals can be measured. This measurement system features the ability to capture fast transient processes such as those occurring in impulse current tests on electrical devices or during switchgear testing. The system is also capable of measuring semistationary and periodic events such as DC voltage and AC voltage as well as superimposed semistationary, periodic and transient processes.

  • Battery Cycler with Low Voltage/High Current Battery

    9220 - NH Research, Inc.

    NHR’s Battery Cycler (9220) has low voltage and high current, designed for testing all battery chemistries including lead-acid, lead-cadmium, and other low voltage, high current, large format batteries (LFB) typically used in energy storage systems (ESS). This battery cycler is bi-directional requiring no additional equipment to charge or discharge the unit-under-test (UUT). Additionally, the built-in measurement system eliminates external measurement devices by providing time-stamped digital readings for voltage, current, power as well as Ah and kWh.

  • Digital (1kV up) H.V. Insulation Tester

    4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.

  • Digital (1kV up) H.V. Insulation Tester

    4104 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV) - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.

  • Digital LOOP/PSC/LOAD Tester

    1825 LP - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.

  • Digital (1kV below) Insulation Tester

    2151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.

  • Portable Test Bench For Single Phase Energy Meter

    SY 2100 - Hong Kong Songyang Industrial Ltd.

    Anthropomorphize design, Large size LCD display, easy operation. High stability, good reliability. Reasonable internal structure. Compliance with IEC736.ISO9001 certificate. Automatic switchover of voltage or current output to protect equipment when voltage circuit short or current circuit open and alarm display on LCD