Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 5116 - 5130 of 6572 items found.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL - Tenma

    The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL DU - Tenma

    The 72-7226 CAL DU from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL D - Tenma

    The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • High Resistance Meter

    HR2 - Alpha Lab, Inc.

    The Model HR2 meter measures resistance in nine ranges from 1 ohm to 1.9999 Tera ohms (1.9999x1012 ohms), and conductance in a single range of 0.00 to 199.99 pS (pico siemens, or pico mhos), all at low voltage of < 2 volts across the sample. Basic accuracy is +/- 2% of reading +/- 1 count. For resistance higher than 1.9999 Tera ohms, the conductance range can be used to measure conductance down to 0.01 pS (100 T ohms). The meter has a conductance range because samples with simultaneously high resistance and high capacitance settle faster to their final value on conductance (usually under one second), than on resistance (several seconds), and conductance is also capable of detecting higher resistance than the resistance ranges can. Note that resistance in units of T ohms is the inverse of conductance in pS, so that the resistance can be calculated from the conductance. For example, 100 pS is 0.01 T ohm (10 G ohm), and the highest readable conductance of 199.99 pS is essentially 5 G ohms.

  • PIN Photodiode

    Appointech, Inc.

    PIN photodiode is a kind of photo detector, it can convert optical signals into electrical signals.This technology was invented in the latest of 1950's. There are three regions in this type of diode. There is a p-region an intrinsic region and an n-region. The p-region and n-region are comparatively heavily doped than the p-region and n-region of usual p-n diodes. The width of the intrinsic region should be larger than the space charge width of a normal p-n junction. The PIN photo diode operates with an applied reverse bias voltage and when the reverse bias is applied, the space charge region must cover the intrinsic region completely. Electron hole pairs are generated in the space charge region by photon absorption. The switching speed of frequency response of photo diode is inversely proportional to the life time. The switching speed can be enhanced by a small minority carrier lifetime. For the photo detector applications where the speed of response is important, the depletion region width should be made as large as possible for small minority carrier lifetime as a result the switch speed also increases.

  • 1000A AC Clamp Meter

    CM55 - Martindale Electric Co. Ltd

    The CM55 is a pocket sized high performance AC Clamp meter measuring AC current, AC/DC voltage and resistance with continuity test. The compact rugged design enables accurate and reliable current measurement down to 10mA resolution without the need to break into the circuit.The CM55 has a CATIII 600V safety rating and is the ideal tool for residential and commercial electricians.

  • Power Interface and Prototype PXI Card

    GX7404 - Terotest Systems Ltd.

    The GX7404 power interface board offers a low cost method for providing controlled power to UUT interface and test circuitry. The GX7404 provides +5 V, +3.3 V, +12 V, and -12 V voltage outputs which are present on the PXI motherboard to be switched through a DB25 connector for use by a UUT (unit under test) and / or interface circuitry.

  • PXI Solid State Very High Density Matrix

    40-501-001 - Pickering Interfaces Ltd.

    The 40-501 is a very high density matrix using solid state switching configured as a 64x4 1-pole matrix in a single slot 3U PXI module. It is ideal for applications requiring fast operation and a long service life with frequent switch operations at high voltages. Since the design is based on solid state relays the matrix has no wear out mechanism.

  • PXI Solid State Very High Density Matrix

    40-500-001 - Pickering Interfaces Ltd.

    A very high density matrix using solid state switching configured as a 64x4 1-pole matrix in a single slot 3U PXI module. It is ideal for applications requiring fast operation and a long service life with frequent switch operations at high currents and voltages. Since the design is based on solid state relays the matrix has no wear out mechanism.

  • Auto-Ranging Digital Clamp Meter

    DCM401 - Draper Tools Ltd

    Expert Quality, auto and manual ranging clamp meter capable of voltage, current, resistance, diode, continuity, capacitance, frequency, duty cycle and temperature testing. Maximum jaw - opening diameter of 36mm, backlit LCD screen, auto power off and a useful inspection light. Supplied with test leads, temp probe, case and 3 x AAA batteries.

  • Coil Testers & Power Supplies

    POB Series - IBEKO Power AB

    Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.

  • RE Family SOTB™ Process-Based Energy Harvesting Embedded Controllers

    Renesas Electronics Corp.

    The RE Family based on Renesas' innovative SOTB™ process technology realizes ultra-low current consumption in both active and standby mode and fast operation at low operation voltage, which is impossible to achieve with a conventional bulk transistor. The energy harvesting controller and 32-bit CPU also enable the development of intelligent and battery maintenance-free energy harvesting IoT devices.

  • Portable Load Bank

    Load Cube - Simplex Inc

    The Simplex Load Cube is an ultra-large capacity, fully portable, resistive/reactive Load Bank System intended for field use in testing, maintenance and performance proving of large generating systems. The Load Cube is rated 2500KW, 1875KVAR at 400-600V commercial AC voltages. The Load Cube is typically used to test large diesel generators, turbines, paralleled generators and shipboard generators.

  • RFI & Acoustic Signal Surveyor

    DFA300 - Doble Engineering

    Use the Doble DFA300 to identify and locate insulation defects.This surveying tool combines radio frequency interference (RFI) and acoustic emission (AE).The The DFA300 partial discharge detector can locate partial discharge (PD) in a few seconds. Designed for surveying live, high voltage apparatus, its versatility makes it the perfect, multi-purpose tool for condition-based maintenance programs.

Get Help