Filter Results By:

Products

Applications

Manufacturers

Voltage

The tension of an electromotive force.


Showing results: 6031 - 6045 of 6572 items found.

  • PXIe-4081, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter

    783130-01 - NI

    PXIe, 7½-Digit, ±1,000 V, Onboard 1.8 MS/s Isolated Digitizer, PXI Digital Multimeter—The PXIe‑4081 is the industry’s most accurate 7½‑digit DMM and provides the measurement capabilities found in two common test instruments: a high-resolution 1,000 V DMM and a digitizer. As a DMM, the PXIe‑4081 delivers fast, accurate AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests. In the high-voltage, isolated digitizer mode, the PXIe‑4081 can acquire waveforms at sample rates up to 1.8 MS/s.

  • PXI Matrix Switch: 8x32, 1-Wire, 100Vrms/2A, Armature Relays

    M9122A - Keysight Technologies

    The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.

  • sbRIO-9213, Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    781210-01 - NI

    Non-Enclosed, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The sbRIO-9213 is a high-density thermocouple input module that is designed for higher-channel-count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The sbRIO-9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO-9213 features NIST-traceable calibration and a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • PXI-2556, 2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module

    778572-56 - NI

    2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2556 is an RF signal multiplexer switch module. The multi-bank architecture of the NI PXI‑2556 makes it ideal for test systems that require parallel operations such as the stimulus/response testing of video RF devices such as tuners. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • PXIe-5774 , 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785646-02 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785647-01 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785647-02 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785996-01 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    779994-02 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9235, 10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785995-01 - NI

    10 kS/s/channel, 120 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9235 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9235 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • PXIe-5774, 12-Bit, 6.4 GS/s, DC-Coupled, 2-Channel PXI FlexRIO Digitizer

    785646-01 - NI

    The PXIe-5774 provides up to 3 GHz of DC-coupled analog bandwidth and 12 bits of resolution. You can operate the PXIe-5774 in a dual-channel mode at 3.2 GS/s or in a single-channel interleaved mode at 6.4 GS/s. The voltage ranges are software-selectable and include 200 mV peak-to-peak and 1 V peak-to-peak, with a selectable DC offset. The PXIe-5774 is ideal for time-domain measurements in areas such as scientific instrumentation, medical imaging, and particle physics. The FlexRIO driver includes support for finite acquisition, and you can implement custom algorithms and real-time signal processing on the LabVIEW-programmable Xilinx Kintex UltraScale FPGA.

  • Battery Conductance Tester

    SAT-AC - Shaanxi Aitelong Technology Co., Ltd

    SAT-AC Battery Conductance Tester is a multi-function and portable digital data storage measurement instrument to test battery running condition and parameters quickly and precisely. It can display and record many key parameters for multi-groups like battery string and each battery cell’s voltage, conductance, connecting strip resistance, battery’s internal resistance and so on; offer the ability to distinguish battery’s condition effectively and accurately; compose with intelligent PC measurement analyzing software, user can track battery’s decay trend, and alarm beforehand to help technician and administrators process according to status.

  • PXI-5122, 100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope

    778756-01 - NI

    100 MHz, 100 MS/s, 14-Bit PXI Oscilloscope—The PXI‑5122 high-resolution PXI oscilloscope has two channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI Oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth. The PXI‑5122 also features PXI synchronization and data streaming capabilities.

Get Help