Showing results: 31 - 45 of 97 items found.
-
LC-series -
Alicat Scientific, Incorporated
The LC-series liquid flow controller uses Alicat’s patented laminar flow design to provide users with fast, accurate, and stable volumetric flow control for water or selected other liquids (see Quick Specs below). At the heart of Alicat’s LC-Series liquid flow controllers is an internally compensated, laminar differential pressure measurement technology that yields linear results over a wide flow range.
-
L Series -
Alicat Scientific, Incorporated
Alicat’s L-series liquid flow meters uses our patented laminar flow design to provide users with fast, accurate, and repeatable volumetric flow measurement for water or selected other liquids (see Quick Specs below). At the heart of Alicat’s L-Series liquid flow meters is an internally compensated, laminar differential pressure measurement technology that yields linear results over a wide flow range.
-
LS-4B -
Hong Kong Songyang Industrial Ltd.
The water meter test bench is made up the platform, clamps, back and front pipe, flow counter group, standard measuring instrument and the outlet valve.When the inlet is connected with the stable water source, the water will get to the standard measuring instrument through the straight pipe. Compare the value of the checked water meter with that of the standard measuring instrument, the valve error that the water meter reads will be acquired.
-
OD-10 -
JFE Advantech Co., Ltd.
Measurement of dissolved oxygen for aeration flow rate control at sewage treatment plants and monitoring of water quality at rivers,lakes,and etc.
-
Argonaut-ADV -
SonTek
Providing robust velocity measurements in a compact, easy-to-use package, the SonTek Argonaut-ADV is the ultimate instrument for shallow water flow monitoring.
-
IM 1910 Serie -
Ajinkya Electronic Systems
The IM 1910 Series Flow Loggers offered by us are micro controller based digital and highly versatile loggers. These can work with external flow sensors offering either electrical output like 4-20mA or 0-10 V or pulses and are used for measuring flow of different kinds of liquids, such as water, diesel & oils.
-
CONTROLSTIK II™ -
Myron L Company
The Myron L® CONTROLSTIK II™ Rinse Tank System dramatically reduces the amount of water used in continuous flow rinse tanks. At the same time, it automatically maintains optimum water purity, ensuring effective rinsing.
-
Shanghai Pubang Sensor Co.,Ltd.
1. Install on the water pipe, strong practicality2. Specialized for water pipe detection,liquid flow detection3. Sensitivity adjuster for easy operation4. Widely applied for liquid level measurement in hydrology, food, environmental protection and other fields
-
Premier Electrosystems
Premier's Flow Rate Indicator-Totaliser accept signals from analog flow meters and display flow rates and volumes on a high visibility LED display. It has relay for control/ alarm. Flow rate indicator cum totaliser are mostly used in Process and Chemical industries, Water treatment plant's distribution system, effluent treatment plants among other applications etc.
-
Wewon Environmental Chambers Co, Ltd.
Water pump for rain test chambers uses highly pressure stainless steel pump, ensure water pressure and flow of the test cycle, the pump is installed in the side of the IP test device, and both ends of the inlet and outlet to set up the joint, easy to replace and repair. Water tank can be disassembled,The corresponding joint or hose connection is arranged in the water pipe connection.
-
McCrometer
The Water Specialties Propeller Meter is the best choice for measuring clean water flows in municipal and industrial applications. The meter is engineered to deliver superior performance, low maintenance and unsurpassed durability. Meter materials and performance meet or exceed AWWA standard C704/92.
-
Picomag -
Endress+Hauser AG
Reliable measurement and monitoring of industrial water, cooling water or warm water. Simultaneous measurement of flow and temperature. Flexible integration into all fieldbus systems via IO-Link. Commissioning and operation via Bluetooth® and SmartBlue App. Minimum conductivity ≥20 μS/cm. Fluid temperature –10 to +70 °C (+14 to +158 °F).
-
Portaflow C -
Fuji Tecom Inc.
The new Fuji Water Flow C uses the same measurement principle as Fuji's ultrasonic flowmeters of which a great number have already been delivered.
-
Omega Engineering, Inc
Omga's Water Quality Transmitters are multi-variable loop powered transmitters that can be configured for use with pH, ORP, Conductivity, or Flow sensors and can be wall, pipe, or pannel mounted
-
Poroscope -
James Instruments Inc.
Poroscope Plus measures the time it takes for air to flow into a known volume of a sealed, evacuated chamber in the concrete. While the vacuum reduces from -55 Kpa to -50 Kpa, a measure of air permeability is determined. For water permeability, Poroscope Plus uses the same chamber filled with water, and measures the total time in seconds for a volume of 0.01 ml of water to escape.