Filter Results By:

Products

Applications

Manufacturers

Water

llquid state of H2O.

See Also: Water Quality, Water Meters


Showing results 901 - 915 of 944 products found.

  • Turbidity Meters

    WTW

    Quality monitoring with turbidity measurement is used in the drinking water and wastewater preparation, but also in many industrial processes as well as in the goods receiving areas of many industries: E.g. turbidity measurement in gasoline for motor development or cell cultures in biotechnology. Turbidity offers unknown opportunities. Due to a LabStation, the portable meters b Turb® 430 are fully functioning benchtop meters. In addition to the standardization process, the application is a decisive factor for the selection: Particle size, number and coloration influence of the samples. The table indicates the best suitability, but not an absolute must. Colored samples with cell cultures yield very different values, depending on the lamp used, but can both be used in the internal quality control.

  • Combined Environmental Reliability Test System

    VTC SERIES - EMIC Corporation

    HALT/HASS testing challenges the design, components, sub-assemblies and final assemblies of today's manufactured products. Stresses are applied through a number of conditions to set operational limits and ultimately precipitate failure in the HALT/HASS test environment. Rapid thermal change rate is one of the classic conditions that facilitate product stress.VTC Series chambers are equipped with an LN2 cooling system, with modulating valve and directed air flow to the product, provides the rapid thermal change rates required to achieve maximum product stress. Additionally, these rates are accomplished with smaller space requirements, lower audible noise, no water requirement, and lower maintenance costs than a typical refrigeration system.

  • Telephone Test Set

    PE930 - Greenlee Communications

    Waterproof tested to an IECIP67 rating, these test sets are so impervious to water they can actually withstand submersion. The PE961 features our DigAlert over-voltage alarm and lock- out function to eliminatethe danger of damaging or knocking out digital service lines. Built-in ADSL Filter. Ten-number speed dial memory (32 digits each). Last number redial. Precise hook flash. Microphone mute. Audible and visual mode indicators. Polarity test in any mode. Unique quick-release beltclip. Premium cord set with bed-of-nails and piercing pin clips. Luminescent Keymat.

  • Xenon Light Source

    PLS-SXE - Beijing Trusttech Technology Co., Ltd.

    PLS-SXE300 (or PLS-SXE300UV) xenon light source is projector light source, which means light irradiate from out of the reactor. It is the most advanced light source wildly used in the field of photocatalysis and photochemistry, including photocatalytic hydrogen production from water, photocaatalytic degradation of pollutants, and experiments using as solar simulator. PLS-SXE300 (or PLS-SXE300UV) light source is specially suitable for experiments in which high energy intensity and long time irradiation are needed. Equipped with band filter, it can be used to evaluate the catalytic performance. The light source has been ordered by over hundred domestic laboratories, including the most famous laboratory in photocatalysis. Today, PLS-SXE300 (or PLS-SXE300UV) has become the standard light source of photocatalytic performance.

  • The Impulse Guided Wave Radar

    AMETEK Drexelbrook

    The Drexelbrook Impulse is a two wire guided wave radar that employs field proven TDR level (Time Domain Reflectometry) technology to provide accurate measurement of Total Level, Distance or Volumetric outputs on all liquids and slurries. The Impulse is designed to tame even the most difficult level measurement applications and will continue to provide reliable and accurate measurements despite disturbances such as agitated, or irregular surfaces, foam or coating of the probe. It is unaffected by changes in density and dielectric properties, dusts, vapor, and turbulence. The Impulse simply keeps on measuring under conditions where other water level sensors quit.

  • Voltage Testers

    DUSPOL - BENNING Elektrotechnik und Elektronik GmbH

    phase-sequence test (counter-clockwise / clockwise)single-pole phase test: " symbol (red LED)measuring point illuminationacoustic and optical continuity testfrequency measurement 1 1000 Hzvoltage indication 1 1000 V AC TRUE RMS / 1200 V DCresistance measurement and diode test with conducting-state voltage indicationlc display with background lightingsensor of non-contact cable break detectorload connection via large-scale push buttonsvibrating alert in the test handleshock-resistant housing with protection against dust and water jets (protection class IP 65) and rubberized test handleDIN EN 61243-3 (VDE 0682-401): 2015 standard

  • Highest Precision Pure Gas Analyzer

    iso DUAL INLET - Elementar Analysensysteme GmbH

    Dual inlet technology is the most precise, accurate and sensitive technique for carbonate and water analysis. Because of this, the iso DUAL INLET has a unique role in the paleoclimate applications where instrumental precision contributes directly to the precision of paleoclimate models. Whilst the world's climate continues to behave erratically, we must know what has happened in Earth's history before we can attempt to predict what will happen in the future. To elucidate this complicated story, the iso DUAL INLET is a valuable tool for paleoclimatologists to build a detailed picture of the past to better inform policy makers who might just be able to influence the future of our planet.

  • Clora Online

    XOS

    Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, Chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online complies with ASTM D7536 method, and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see impacts of crude changes (including organic chloride). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

  • Automatic Mercury Analyzer

    5E-HGT2320 - CHANGSHA KAIYUAN INSTRUMENTS CO., LTD.

    5E-HGT2320 Automatic Mercury Analyzer is used to determine the mercury in liquid and solid material such as coal, coal fly ash, soil, sludge, sediment, ore, mineral, foodstuff, waste water and fodder. 5E-HGT2320 is a direct mercury analyzer of solid and liquid samples which employs the thermal decomposition process described in U.S. EPA Method 7473. The samples are firstly dried, in which moisture shall be discharged in a form of vapor by a three-way valve. Then the sample is thermally decomposed in an oxygen-rich stream and the decomposition products are carried by flowing oxygen to the catalytic section of the furnace, where oxidation is completed and all interfering substances, such as halogens and nitrogen/sulfur oxides are eliminated. The remaining decomposition products are further carried to a gold amalgamator where the mercury is selectively trapped.

  • Eddy Current Sensor

    eddyNCDT 3001 - Micro-Epsilon Group

    The eddyNCDT 3001 is a new, efficient eddy current sensor whose compact dimensions have to date only been reserved for inductive sensors and proximity sensors. The temperature-compensated design provides high stability even in fluctuating ambient temperatures. The eddyNCDT 3001 comes with integrated electronics, offering an outstanding price/performance ratio and easy operation. The eddyNCDT 3001 eddy current sensor is ideally suited to OEM integration and machine building applications. The sensor is factory-calibrated for ferromagnetic and non-ferromagnetic materials, which eliminates the need for field calibration of the sensor. The eddyNCDT 3001 is available with connector or with integrated cable. A robust design combined with the eddy current measuring principle enables measurements in harsh industrial environments (oil, pressure, dirt). In addition, the eddyNCDT 3001 is suitable for offshore/marine applications (salt water).

  • Digital Pressure Transmitter

    HR8106 - HighReach Measuring & Controlling System Co.,Ltd

    HR8106 digital pressure transmitter is one kind of high accuracy pressure measurement products with mixed signal processing technology and unique compensation methods to realize F S digital linearity correction, full temperature digital temperature compensation, compensation data stored in nonvolatile memory, multiple safety protection system to avoid the products cannot be used due to correction data lost; Circuit part with power and watchdog monitor, mechanical part with full seal stainless steel structure, both of them improve the reliability of the whole transmitter. The product with the feature of low power consumption(power consumption is 4mA under full work)which is very useful at battery power condition.Currently, HR8106 is widely used in pressure measurement, hydrology and water conservancy and geologic survey area.

  • Digital Pulse Output

    ATP Series - Automation Components Inc.

    ATP-R converts an analog signal into a digital pulse output signal. The user can select eight standard analog input ranges to the ATP by changing jumper shunt positions. To select the output pulse range, the ATP has an eight position DIP switch. The output pulse is continuous with a one second off between pulses. ATP-R Version 2 operates the same except no pulse output occurs when the analog input falls to, or below 10% of the input signal range. This allows for a true "OFF" setting for solid state relays controlling electric heat. The ATP-T is a Triac Output (24VAC only). You need to contact ACIfor technical asistance when ordering. ATP-Y is a also a Form C Relay Output (24VAC or VDC) with an option of two pulse ouput ranges designed to communicate with York(TM) Chiller Control Packages. Some chiller control panels require a 1-11 or 0-21 second pulse to remotely reset chilled water temperatures.

  • Dual Channel Conductivity-Resistivity Controller

    8860 - Georg Fischer Signet

    The Signet 8860 Dual Channel Conductivity/Resistivity Controller is a two-channel input device equipped with three scaleable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. Dual input and advanced control capability, including percent rejection, difference and ratio calculations, together with Signet Conductivity Sensors, form the perfect measurement and control system for water treatment applications and more. Two versions are available: once accepts AC line-voltage, the other low voltage DC for power. The four-button keypad arrangement with intuitive software design is user-friendly, and the NEMA 4X/IP65 front panel with self-healing window in a 1/4 DIN package for easy panel installation.

  • Miller 400D

    44550 - M. C. Miller Company

    No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)

  • Non-Contact Voltage Tester

    NCVT-3 - Klein Tools, Inc.

    Provides non-contact detection of AC voltage.Detects 12 – 1000V AC with simultaneous visual and audible voltage indicators.Bright flashlight illuminates work area and may be used independent of voltage detection function.Visual LED bar graph indicates the presence of voltage – the higher the voltage sensed, or the closer to the voltage source, the more LEDs light up.Bar graph visual voltage indicator utilizes up to five vibrant LEDs for easy interpretation/viewing.Audible voltage indicator beeps at a greater frequency the higher the voltage that is sensed, or the closer to the voltage source.“Auto Power-Off” conserves and extends battery life.Screw-thread battery cap with O-ring ensures protection against dust and water ingress.Lightweight, compact tool with pocket clip provides convenient storage and quick access.IP67: Dustproof and waterproof.6.6 feet / 2 meter drop protection.CAT IV safety rating for 1000V.Conforms to CE requirements.