Showing results: 361 - 375 of 832 items found.
-
MICRONIX
The necessity of a wireless system test has risen by the spread of recent wireless telecommunication equipment as shown in cellular phone, wireless LAN, RF-ID tag and ETC (Electronic Toll Collection system). It is necessary for a wireless test to be performed in anechoic environment in which an external noise is intercepted and a radio wave does not reflect internally. An anechoic chamber (room version of a shield box) is proper facilities but needs a wide space and a huge cost. Especially, the equipment under wireless system test on the production line can not radiate any signal radio wave outside before approval. The shield box satisfies these conditions.
-
785034-01 -
NI
PXIe, Rubidium PXI Synchronization Module - The PXIe-3352 generates high-stability clock signals for PXI or third-party instrumentation. It provides a high-accuracy sine wave, square wave, or 1 pps output, and it includes a built-in GPS receiver (external antenna required) to discipline the rubidium oscillator for long-term stability. The front panel DC power input maintains power to the rubidium oscillator if the PXI chassis is powered off, keeping the rubidium oscillator stable over time and eliminating the effects of retrace. The GPS receiver also maintains its location information during power off for fast system bring up.
-
MVG EME Guard XS 6GHz -
LBA Group, Inc
The EME Guard XS is an RF measuring device to alert workers near RF emitters for protection of climbers and other RF-exposed workers. It continuously scans for electromagnetic waves and, via its built-in alarm and visual system, alerts users whenever the acceptable pre-selected limits have been exceeded. This RF Safety PPE is extremely easy to use and supports a safer working environment in the areas of installation and maintenance.
-
40-760-002 -
Pickering Interfaces Ltd.
This dual 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-762-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-760-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-762-002 -
Pickering Interfaces Ltd.
This dual 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-764-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-762-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-764-002 -
Pickering Interfaces Ltd.
This dual 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-766-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-760-008 -
Pickering Interfaces Ltd.
This octal 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Ducommun Inc
Ducommun is a leading global supplier of RF Products for Commercial Aerospace, Military & Space markets. We partner with top-tier OEMs and primes because of our unique, comprehensive understanding of electro-mechanical and RF principles. Whether you need a standard, off-the-shelf or in-stock coaxial switch, or a highly customized millimeter wave product, Ducommun offers a range of products and solutions to meet your program and design requirements.
-
40-765-001 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
40-761-004 -
Pickering Interfaces Ltd.
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.