Filter Results By:

Products

Applications

Manufacturers

Winding

conductor wire wound or coiled around a magnetic core.

See Also: Transformer Turns Ratio


Showing results: 151 - 165 of 227 items found.

  • Static & Lighting Chokes

    LBA Group, Inc

    Lighting chokes are used to pass tower lighting voltages across the base insulator of a series-fed tower without appreciably altering the tower impedance. LBA TC-300 general purpose tower lighting chokes are provided for three wire 110/220 VAC circuits. Maximum current is 25 amps. These chokes are rated for peak base voltages to 10,000 volts, and present a typical reactance of +j5000 ohms at 530 kHz. Bypass capacitors are provided on each winding.

  • Sweep Frequency Response Analyzer

    M5400 - Doble Engineering

    The M5400 sends an excitation signal into the transformer and measures the returning signals. Comparing this response to baseline readings and results from similar units allows you to identify deviations and confirm internal mechanical problems.The M5400 reduces the uncertainty about apparatus condition by providing solid evidence of mechanical integrity or winding movement. Use it to help determine how a transformer is deteriorating, if it can go back in service after a fault or if it has been damaged during transit.

  • Core Loss Testers

    S30 and S30S Series - Ferrites India

    Stacks built with punched laminations can have a lot of quality issues. Even though the lamination material is tested in sheet format before any process, that alone is not sufficient to guarantee good quality stators. Wear and tear of the punch, bad welding, bad insulating coating in annealing add to the magnetic losses in the stator. It is always advisable to test the stator core in it's final format before winding to ensure good quality throughout the production batch.

  • Magnetic Material Test Fixture

    16454A - Keysight Technologies

    The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.

  • Speed Pick-up

    SU63 - Validyne Engineering

    The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.

  • Primary Current Injection Test Set

    T 2000 - Altanova Group

    T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.

  • Insulation Resistance Tester

    Aarohi Embedded Systems Pvt. Ltd

    Aarohi make device enable us to measure electrical leakage in wire, results are very reliable as we shall be passing electric current through device while we are testing. The equipment basically uses for verifying the electrical insulation level of any device such as motors, cables, generators, windings, etc.

  • TOROIDAL COIL TURNS TESTER

    TURNS-TTPT - Vasavi Electronics

    Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns

  • Current Transformer Tester

    HTCT-300 - Lisun Electronics Inc.

    Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.

  • Transformer Demagnetization Tester

    Weshine Electric Manufacturing Co., Ltd

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.

  • Electrical Safety Test Solutions

    Chroma ATE Inc.

    Hipot Analyzers with 500VA output rating can be used to test and analyze the withstand voltage of high power and leakage current for the products like motor stators and rotors with high parasitic capacitance. Corona detection can be used for turn-to-turn or turn-to-ground test to avoid winding insulation failure from corona discharge.

  • Signature Model High Frequency Surge Testers

    S - PJ Electronics, Inc.

    Bench size performance & durability with PJ's exclusive/unique High Frequency Technology capable of testing the integrity of any turn to turn insulation, including low inductance windings. These Digital Surge Testers come standard with a rack-mounted, Tektronix TDS1002, 1 Billion Samples/sec, real time, programmable, storage oscilloscope.

  • Quasi Square Wave Constant Voltage Transformers

    Osborne Transformer Corp.

    Osborne Quasi Square Wave Constant Voltage Transformers are used to regulate output voltages for applications that have varying input voltages. When used with a rectifier conversion circuit, these units provide an elegant design approach to voltage regulation. Osborne achieves this innovative approach by partnering the constant voltage transformer with an auxiliary resonant capacitor winding. The result is a unique (though time honored) technology that offers reliability, performance, and cost advantages over other styles of voltage regulation.

  • Precision Capacitance and Dissipation Bridge

    SG2008 - Shanghai Jiuzhi Electric Co., Ltd.

    SG2008 Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation (tgδ) and capacitance (C) in heavy electromagnetic interference environment such as in power plants or substations. Also it can be used in laboratory for high accurate test such asHigh Voltage (EHV) class Bushings, Windings of transformer (1/2/3 windings), shunt reactors, Current Transformer, Capacitor Voltage transformer(CVT), grading capacitors of Circuit Breakers, Surge Arrester and other electrical equipments. The test set is all-in-one structure: including precision digital bridge, 12kV/200mA frequency conversion power unit, reference capacitor (CN), and other electronic circuits. An external power supply can expand the test range. True portability is realized by the lightweight. Simple usage is realized by the full automation. High performance is realized by the digital process.

  • Goniophotometer

    Hangzhou Hopoo Optoelectronics Technology Co., Ltd

    This system uses the method of fixing the detector and rotating the lamp under test to measure the light intensity distribution of the light source or lamp under test in all directions in the space. The main shaft and the lamp shaft adopt the conductive slip ring with precious metal fiber point brush structure, which can run 360 degrees continuously without backlash for measurement. There is no need to rotate back and forth to prevent winding and never winding. According to the requirements of the measuring lamps, the system can be configured as a double-column B-β test scheme or a single-column C-γ test scheme. Used for LED lamps (semiconductor lighting), road lamps, floodlights, indoor lamps, outdoor lamps, etc. and LED, energy-saving lamps, fluorescent lamps, incandescent lamps, HID lamps and other light sources of spatial luminosity distribution

Get Help