Showing results: 76 - 90 of 227 items found.
-
NDB-DOC™ -
ndb Technologies Inc.
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
DOC-2000™ -
ndb Technologies Inc.
The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
1000 -
International Electro-Magnetics, Inc.
The Model 1000 is designed to be used in production environments to test for actual turns on toroidal cores. It is able to test single winding toroids as well as multiple windings. It automatically compensates for variations in core permeability.
-
Osborne Transformer Corp.
Osborne Saturable Reactors are designed to provide a variable output voltage through the use of variable impedance connected in series with a constant impedance load. Each saturable reactor’s impedance is determined by the application of DC power to a control winding. As the level of power supplied to the control winding is increased, the saturable reactor becomes more saturated. This reduces the impedance of the AC gate winding, and increase the amount of the supply voltage that is transferred to the load. Conversely, as the power is reduced to the control winding, the reactor becomes less saturated, the gate winding has more impedance and less of the input voltage is provided to the output impedance. This approach provides excellent quality, reliability, and control when designed to match the requirements of a specific application.
-
STDE -
Altanova Group
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
TRM 1000 -
AJIT Electronics Co.
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
865 -
The Eastern Specialty Company
This instrument is used to check the correctness of polarity markings on transformers. In operation, the two leads carrying the test current are connected to one of the transformer windings. The other two leads from the indicating meter are connected to the other winding.
-
AD-7010 -
ADEX Urzadzenia Pomiarowe
AD-7010 instrument is designed to measure, with high accuracy, the resistance of conductive elements power equipment: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of bolted joints, crimped, welded, the contacts of switches and relays.
-
SPS electronic GmbH
With the partial discharge test devices from SPS electronic, you can detect quality defects in windings before they have an impact. In order to determine potential partial discharges, a high-voltage pulse is applied to a test object (e.g. stators, rotors or finished motors). The partial discharge measurement from winding to body (housing) can be carried out with one of our high-voltage testers. Our surge voltage testers can be used for winding-to-winding (and body) measurements.
-
AD-7110 -
ADEX Urzadzenia Pomiarowe
The instrument AD-7110 is designed to measure, with high accuracy, resistance conductive elements of power devices: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of screw connections, crimp, welded state of the contacts of switches and relays current up to 100 A .
-
-
THPG -
Whitelegg Machines Ltd
Very Heavy Duty with high milliamp capacity for properly testing motors and windings.
-
Iris Power LP
Offline testing solutions to determine the condition of stator windings, stator core and rotor in generators and motors
-
NDB-DOC-3™ -
ndb Technologies Inc.
The NDB-DOC-3™ is a test instrument designed for distribution networks transformers from 5kVA to 3MVA. It can determine the presence of short circuits or open circuits in the distribution transformer primary winding & also short circuits on the secondary winding.The NDB-DOC-3™ is designed to be operated without disconnecting the transformer’s secondary windings from their loads.
-
61-797 -
IDEAL Industries, Inc.
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty