Showing results: 106 - 120 of 227 items found.
-
Iris Power LP
Rotor magnetic flux variations are the result of the degradation of the rotor winding insulation by mechanisms like load cycling, thermal aging and contamination. Iris Power provides solutions for measuring the magnetic flux in the generator in order to plan maintenance requirements.
-
CT Analyzer -
OMICRON electronics
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
PT-1 -
International Electro-Magnetics, Inc.
The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.
-
Citizen Chiba Precision Co., Ltd.
*High output *The rotor uses Nd magnets. *The stator was designed for maximum output per unit volume to maximize winding.*Long service life *Since these are brushless motors, the only limit to service life is how long the ball bearings last.
-
-
600V Class -
AYA-Instruments
These transformers are encased in a thermoplastic case with the core and windings encapsulated in resin. They are designed for line-to-line operation but may also be used in line-to-neutral or line-to-ground configuration at 58% of rated voltage. It is recommended that a 1.6 Amp fuse be used in the secondary to protect the transformer.
-
HVST -
Test Electronics
The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. This voltage is displayed on an oscilloscope and recorded on the Pass/ Fail LED latch monitor. This voltage will be accurate despite the impedance of the winding being tested. The insulation system can be tested way above the operating voltage because of the brief duration of the applied voltage test pulse. This allows faults to be detected long before they become apparent at operating conditions.
-
Osborne Transformer Corp.
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
GTB Series -
Wuhan Sangao Electrical Test Installations Limit Co.
GTB series dry testing transformer is adopted with new technology of winding epoxy vacuum pouring and CD type Iron core. Compared with similar product of oil immersed type transformer, it is light weight, smaller size, insulation strength and moisture-resistant is more improved.
-
STCS -
Altanova Group
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
MPK-253 -
MEGABRAS srl
The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.
-
Changzhou Tonghui Electronic Co., Ltd.
Tonghui Automatic Test Systems - switching power supply automatic test system, winding component automatic test system, inductance bias feature test system, etc.
-
MPK-254 -
MEGABRAS srl
The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.
-
MTC 2 -
Whitelegg Machines Ltd
Advanced automatic high precision electrical winding testers for testing products like alternators, stators, transformers, armatures and motors. Available as static or portable units from 6-50 kV.
-
SPS electronic GmbH
The impulse voltage test devices from SPS electronic are ideal for detecting interturn faults and insulation faults within a winding - even before the fault affects the electrical specifications of the test object.