Showing results: 16 - 30 of 1050 items found.
-
55KS1 -
North Atlantic Industries
NAI’s 55KS1 is a 75-Watt DC/DC Converter that accepts a +28 VDC input. This COTS unit provides full-power, single output, at a baseplate temperature of +100° C.
-
VPX55HS -
North Atlantic Industries
NAI’s VPX55HS-31 is NAI's latest +28 VDC Input, VPX DC/DC Converter. The VPX55HS was developed in alignment of the SOSA™ Technical Standard and is capable of handling up to 725 Watts of output power. It plugs directly into a standard 3U VPX chassis with a VITA 62 1.0” power supply slot. This off-the-shelf solution for VITA 46.0 and VITA 65 systems is compatible with VPX specifications; supports all VITA standard I/O, signals, and features; and conforms to the VITA 62 mechanical and electrical requirements for modular power supplies.
-
Computer Conversions Corporation
This unique series of Synchro to DC Converters makes use of advanced digital circuitry techniques to accomplish high speed conversion with extreme accuracy. Transformer isolation as well as balanced line-to-line input impedance is provided for superior and trouble-free system performance, regardless of the input synchro used.
-
781037-01 -
NI
PXIe, OCXO PXI Synchronization Module—The PXIe‑6674T generates and routes clocks and triggers between devices in a PXI Express chassis as well as to other PXI and PXI Express chassis or third-party instrumentation. The PXIe‑6674T unlocks the advanced low-voltage differential signaling (LVDS) trigger signals PXIe‑DStarA, PXIe‑DStarB, and PXIe‑DStarC, on PXI Express while fully supporting the PXI trigger lines. The PXIe‑6674T can generate two types of clock signals: a highly stable 10 MHz clock based on an onboard precision oven-controlled crystal oscillator (OCXO) reference and a second clock from the direct digital synthesis (DDS) clock generation circuit.
-
785034-01 -
NI
PXIe, Rubidium PXI Synchronization Module - The PXIe-3352 generates high-stability clock signals for PXI or third-party instrumentation. It provides a high-accuracy sine wave, square wave, or 1 pps output, and it includes a built-in GPS receiver (external antenna required) to discipline the rubidium oscillator for long-term stability. The front panel DC power input maintains power to the rubidium oscillator if the PXI chassis is powered off, keeping the rubidium oscillator stable over time and eliminating the effects of retrace. The GPS receiver also maintains its location information during power off for fast system bring up.
-
N5747A -
Keysight Technologies
The single output, 750W N5747A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-201-008 -
Pickering Interfaces Ltd.
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
40-190B-402 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
40-190B-302 -
Pickering Interfaces Ltd.
The Dual Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-502 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
50-190-201 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-001 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-190-101 -
Pickering Interfaces Ltd.
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
50-200-008 -
Pickering Interfaces Ltd.
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.