  • Power Factor Correction

    HV/MV - Ducati energia S. p. A.

    Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.

  • Test Set For Instrument Transformer

    NEO TELE-TRONIX PVT. LTD

    This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.

  • MOTORIZED VARIABLE TRANSFORMER CONTROLLED POWER SUPPLY

    Carl E. Holmes Company

    Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure

  • CT Burden Tester

    585 - Radian Research, Inc.

    The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.

  • Reactive Energy Regulator

    MASTER - Lifasa - International Capacitors, SA

    It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.

  • TOROIDAL COIL TURNS TESTER

    TURNS-TTPT - Vasavi Electronics

    Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns

  • Step & Contact Meter

    HT2055 - HT Italia Srl

    HT2055 consists in a power unit and a voltmetric unit, necessary for carrying out step and contact voltage measurements in industrial electric installations (TN systems, transformer cabinets) with a rated test current up to 50A.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TW Series - IBEKO Power AB

    RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.

  • CT Polarity Tester

    DIR CT - Scope T&M Pvt, Ltd.

    SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations

  • Extra-Ground Current Impuision Equipment

    JYQ - Kingrun Instrument Co., Ltd.

    Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.

  • 20Hz Injection Kit Monitoring System

    Signals & Systems India Private Limited

    The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.

  • Transformer Winding Resistance Meter

    XWRM-10 - The Motwane Manufacturing Company

    The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.

  • Transformer Turns Ratio Meter

    TTRM 302 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • Transformer Turns Ratio Meter

    TTRM 301 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.

  • DIGITAL TURNS TESTER & DIGITAL LCRTZ METER (TURNS-LCRTZ)

    Vasavi Electronics

    Coil Turns Tester , Turns Tester , Turns Counter , Coil Turns Counter , Toroidal Turns Tester , Bobbin Turns Tester , Coil Turns Tester , Ratio Turns Tester / Counter for Toroidal Coils, Current Transformer