SHANGHAI POWOO INDUSTRY
Technical specification of phantom load power sourcePower and consumption:Power supply: 1P2W 220V ±10%, 50Hz / 60Hz;Max consumption: 700VADimension: 500mm X 350mm X 650mmCurrent source:Output current: 3×0.001A - 3×100AAdjusting resolution: 0.01% (min. 0.0001A)Power factor: -1.0 ~ 1.0(0~3600; resolution: 0.10)Outputfrequency: 45Hz~65Hz;THD(sine wave output): <0.8%Stability of current during sine wave output:0.05% (180s)Output wave: sine waveOutput capacity: 150VA per phase Voltage source:Output voltage: 3×30V - 3×300VLoad: The Load could be resistor / inductive / capacitive(<4uF)Adjusting resolution: 0.01% (min. 0.1V)Outputfrequency: 45Hz~65Hz;THD (sine wave output): <0.8%Voltage stability of power source during sine wave output:0.05% (180s) Output wave: sine wave Output capacity: 15VA per meter position
-
CSJ-100 - Greenlee Communications
AC amperage, AC/DC voltage measurement. Open jaw design eases AC current measurement. Slim profile with built-in probes storage on back. Measures resistance up to 20MÙ. Audible continuity and diode test. Bright LED and audible alarm for non-contact voltage detection.
-
Newport Electronics
DC voltmeter which provides high-resolution and high-accuracy at very reasonable cost. Display span is ±19,999 counts. Accuracy 99.98% of reading. The 2003B also provides exceptional stability and noise rejection. Its conversion circuit uses a crystal oscillator, which is tuned for either 50 or 60 Hz rejection.
-
RC Electronics, Inc.
measures eight DC values: Amps: (0-100 peak) Peak Amps & peak Watts Amp-Hours (Ah): (0 - 65) Watt-hours (Wh): (0 - 6554) Watts: (0 - 6554) Minimum voltage ("sags") Voltage: (0 - 60)Better than the dc ammeter of a digital multimeter (DMM) because of much higher current, lower insertion resistance and eight total measurements.
-
CyberScan pH 2100 - Eutech Instruments
High Resolution and Accuracy (Up to ±0.002 pH Accuracy) for precise measurementBacklit Two Line, Dot Matrix LCD Display provides clear instructions for setup, measurement and calibration
-
ADM - Lasermet Ltd.
Super-fast response times down to 700 ns using the Lasermet Advanced Detector Interface. Exceptionally high accuracy and repeatability. Peak power, energy per pulse andaverage power measurements. Display and measurement of pulsed waveforms up to 400 kHz.
-
KM-2007 - KUSAM-MECO
3¾ digits LCD with maximum reading 4000, plus decimal point, unit symbol indication.*Overload indication: LCD will show "OL" in the left position.* Low battery indication: Replace battery immediately when LCD display " "
-
FC3-0812 - Fox Delta
Fc3 is designed and developed for Radio Amateurs looking for economical frequency counter for their hobby work and wish to measure RF signal Level at the same time.
-
MM1 - Axe Technology Corp.
Accuracy 0.1% F.S. 1digit. Measuring DCA/DCV/ACA/ACV/Potentiometer/Transmitter/Pt-100/Thermocouple/Load Cell/Resistor/etc. Programmable rate -19999 to 99999 digit. Auto zero or hold or dual display function)(optional). Decimal point can be modified. Dimension small and High stability
-
MMS - Axe Technology Corp.
Accuracy 0.1% F.S. 1digit. Measuring DCA/DCV/ACA/ACV/Potentiometer/Transmitter/Pt-100/Load Cell/Resistor/ect. Programmable rate -19999 to 99999 digit. Auto zero or hold or dual display function (Optional). Decimal point can be modifed. Dimension small and High stability
-
#01444 - Tenergy Corp.
Number of Cells: NiMH/NiCd: 4-7 cells; LiPo/Li-ion/LiFePO4: 1-7 cells
-
MRC ltd.
Display: 4 digits LCD, maximum reading 9999 Range: 20/2000 mG,2/20/200TResolution: 0.1/1 mG or 0 .001/0 .01/0 .1 TAccuracy: (2.5%+5dgt) at 50Hz/60Hz (5.0%+5 dgt) at 30Hz-2000HzSensor: Triple AxisFrequency response: 30Hz to 2000HzOperating temperature & humidity: 5'Cto 40'C, below 80% RHWeight: About 230g
-
-
ST-109 - TENMARS ELECTRONICS CO., LTD.
Frequency range: 10Hz ~20KHz.- Measurement range:30dB~130dB.- Dynamic range:100dB.- A/C/Z frequency weighting.- Fast, Slow, Impulse Peak response time.- DC & AC Output.- Bargraph display.- USB interface.- Storage 37,000 records, auto-mating transfer to micro SD card.- Comply with the following standards:IEC 61672-1 : 2002 Class1ANSI S1.4 Type 1CNS NO.7129 Type 1 JJG-188-2002 Class1
-
CTL-400 - CellCare Technologies Ltd.
The New Cellcorder CTL-400 launched in summer 2007 is the latest product version in the leading line of CellCorder battery test instruments.