Meters: sense and display measures of gas, water, electricity, particles, vibration or light.

Showing results 2401 - 2415 of 4489 products found

  • Sound Level Meter & Real-time Analyzer

    824 - Larson Davis, Inc.

    The Larson Davis System 824 combines advanced sound level meter and real-time analyzer capabilities into a rugged, user-friendly, ergonomic package. The base unit is an Integrating Sound Level Meter (ISM) that meets Type 1 Standards and offers simultaneous measurement of sound pressure levels using fast, slow, and impulse detectors, for A, C, and flat frequency weightings. This feature, termed ANY LEVEL™ measures 48 sound pressure parameters at once with a linear, 105 dB range. With firmware enhancements, the base unit expands as needed to accommodate multiple data processing requirements

  • EPM Series Dual-Channel Power Meter

    N1914A - Keysight Technologies

    Frequency range of 9 kHz to 110 GHz (sensor dependent)Wide dynamic range of -70 to +44 dBm (sensor dependent)Speed improvement by 2X for E-Series sensors: up to 400 readings/secGo beyond GPIB with LAN LXI-C and USB connectivityCode-compatible with E4418B, E4419B power meters*Code-compatible with 436A, 437B and 438A power meters (option 200)Increased measurement channels: up to three channels with two additional U2000 Series power sensors connected using the optional USB hostsAutomated frequency/power sweep measurements with the optional external trigger in/out feature

  • EPM Series Single-Channel Power Meter

    N1913A - Keysight Technologies

    Frequency range of 9 kHz to 110 GHz (sensor dependent)Wide dynamic range of -70 to +44 dBm (sensor dependent)Speed improvement by 2X for E-Series sensors: up to 400 readings/secGo beyond GPIB with LAN LXI-C and USB connectivityCode-compatible with E4418B, E4419B power meters*Code-compatible with 436A, 437B and 438A power meters (option 200)Increased measurement channels: up to three channels with two additional U2000 Series power sensors connected using the optional USB hostsAutomated frequency/power sweep measurements with the optional external trigger in/out feature

  • Automatic Water Meter Test Bench

    SHANGHAI POWOO INDUSTRY

    System features It can test according to ISO 4064 or OIML R49 For the same lot of water meters, you need to have parameters setting only for one time. WA10-DN15-DN25 for 1-10 meters in series. Adopt laser testing head from Japanese SUNX and numerical laser sensor amplifier. Laser testing head has virtues of small optical spot (0.2mm), long verification distance (reach 500mm). Numerical laser sensor amplifier can respond very rapidly ( Maximum speed: 80 microsecond ,that is, 12.5KHz/s) It has focusing instructed function. Adopt TCS Series Electronic Balance from one of largest electronic scale sensors manufacturer companies in China. The scale has virtues of high precision, high stability, easy operation, convenient information collection etc. It has instantaneous flow adjusting function. It has automatic abrasion test function of ten thousand times (interrupting test, or to say fatigue test). (No need to purchase ten thousand times wear tester specially). It has the functions of automatic monitoring, display of pressure and water temperature in pipeline. It can have verification repeatedly, and you needn't reset the parameters. It can print various reports respectively. It can have pressure verification for water meter. All the information about the tested water meter will be collected, calculated, displayed and transmitted by independent optical collector and adjustable optical sensor. The equipment has water circulated function, and has virtues of low noise, high stability. It can adapt to all kinds of mechanical water meters verification, and is very flexible. The equipment is made of 304 stainless steel and copper. Sufficient spares for wearing parts are (like o washer etc). Low fault rate, convenient repair.n With full technical documents.

  • Analog TV signal level meter

    HT828B - Hangzhou Softel Optic Co., Ltd.

    The signal level meter, SE828C is able to measure EQ, C/N, V/A and trunk volt in the CATV analog system, the number keys is designed to direct input frequency so that work would be easier. It can measure 2 channels at the same time.

  • Ampere Hour Meter With Three Doser

    IM2509 - Ajinkya Electronic Systems

    IM2509 model ampere hour meter is provided with three control relay outputs to facilitate addition of three chemicals. It should be noted that this feature is improvement over the IM2503 model which offers two control relay outputs to control a addition of two chemicals.The other features of IM2502C model are retained in this model.

  • Broadband field meter with data logger

    NBM-550 - Narda Safety Test Solutions

    Broadband field meter with data logger for electric and magnetic field measurements from RF to microwave. Available with isotropic probes to cover 100 kHz to 60 GHz. Large graphical display. Plug-and-play probe interface with automatic probe parameter detection

  • Battery Monittoring Ampere Hour Meter

    IM2505 - Ajinkya Electronic Systems

    IM2505 is a charge discharge type Ampere Hour Meter which is useful for tracking / monitoring battery AH in circuit.These are used in applications related to submarine and telecom or in these sectors where battery back ups are used and battery charge is to be monitored to switch on and off charger and load to avoid excessive charging as well as deep discharge.

  • Automatic Single Phase Meter Tester

    585B - Red Phase Instruments Australia Pty Ltd.

    The Model 585B is designed as a low cost, fully automatic single phase meter tester. A microprocessor is incorporated in this tester to conduct the test sequence and calculate results. Test results are displayed on a back-lit LCD display or hard copy of the tests can be printed out automatically when required. 

  • Carbon Sensor Conductivity Meter High-Concentration

    HE-960HC - HORIBA, Ltd.

    FPD manufacturing processesThe HE-960HC measures conductivity, which forms the basis for parameters in chemical and waste water management. Its dual calculation circuits and software, combined with carbon sensors, enable measurements ranging without switching. The HE-960HC can be used as a process concentration meter, and also to monitor changes in the concentration of specified chemicals.

  • Charge Discharge Ampere Hour Meter

    IM2507 - Ajinkya Electronic Systems

    IM2507 is a charge discharge type Ampere Hour meter which has two independent 4 digit displays for separate charge and discharge counting. While one display counts the charge through the circuit, the other counts the discharge.These are useful in battery life cycle testing, battery monitoring applications.

  • Dual Channel Universal Power Meter

    Model 8652A - Spanawave Corporation

    The Spanawave/Giga-tronics 8652A Dual Channel Universal Power Meter has the extensive measurement capabilities and features you need to test today's sophisticated communications systems faster, easier and more accurately. 100 kHz to 40 GHz Frequency Range, depending on sensor. -70 to +47 dBm Power Range, depending on sensor.

  • DIGITAL SAT METER, 930-2150 MHz

    SDM2 - Rover Instruments

    DIGITAL SAT METER, 930-2150 MHzfor EASY DISH POINTING (safe and precise), QPSK demodulator with measurements: BER and Noise Margin * Automatic quality analysis: FAIL-MARG-PASS * Level/Power * Automatic SAT identification with DiSEqC commands and 99 transponder/orbital positions, storable in a PC

  • Dual Type IV Power Meter

    1806 - TEGAM Inc.

    Designed for use with bolometer elements to measure high frequency or microwave power from 10W to 30 mW. Model 1806 also functions as a standard for the calibration of bolometers mounts, detectors, RF voltmeters, and for precision insertion loss measurements when used with the TEGAM System IIA, automatic power meter calibration system.

  • Current Limit Ampere Hour Meter

    IM2512 - Ajinkya Electronic Systems

    IM2512 is a 4 digit Ampere hour meter with a current limit relay. It has all the features of standard IM2501 C model, in addition a current set point. Typically, while in the charging process, when a battery is sufficiently charged, the current flow drops to a lower level. At this juncture, the battery must be disconnected from the source of power.

Products

Applications

Manufacturers