JR-1
12820
• 35 Amp relay [@ 24VDC max. or @ 48VAC max.]• Crystal controlled timing• Rechargeable battery• Immediate or delayed interruption operation• Low battery indicator• Countdown and relay status indicators• On and off cycle times up to 999.9 seconds• Synchronized operation with any number of JR-1's and JR-2's
-
product
Miller 400A
44500
Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source
-
product
Miller 400D
44550
No need to select ranges or adjust dials – the Miller 400D provides a direct read-out of resistance with the push of a button• Bluetooth interface allows optional data-logging via a Bluetooth-enabled PC (or PDA)**• Rugged, hard plastic case - safe to use on wet ground – IP67 rating for dust and water intrusion• Resistance measurement range from 0.01Ω to 10MΩ (auto-ranging) • High resolution digital display• Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 82.2Hz (the unit’s operating frequency)• Runs on a set of replaceable D-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source• Performs 10,000 single readings on a fresh set of batteries• Integrates with Universal Rectifiers’ Soil Depth Selector/Multi-Pin Cable Harness System (please see Integration with Universal Rectifiers’ Cable Harness)
-
product
Concrete Corrosion Mapping System
15620
Our Concrete Corrosion Mapping System (CCMS) can be used to satisfy the ASTM C-876 standard test method and the kit contains all equipment items that are needed to perform a corrosion survey on virtually all types of reinforced concrete structures, such as bridges, highway slabs and parking garages.
-
product
Data-logger
11250
Comes loaded with M. C. Miller's Test Site Survey application• Integrates with ProActive, M. C. Miller's corrosion control data management application• Data-types are customizable for each of your test sites and each test site can be GPS position stamped • High-resolution date/time stamped photos can be taken at your test sites during a route and recorded images are posted directly to the ProActive database • Sub-meter GPS position resolution
-
product
LC-4.5 Voltmeter
5203
Model LC-4.5 is the first hand-held voltmeter to include a number of special features which facilitate corrosion and cathodic protection testing on underground structures. It is designed for field testing under almost any environmental conditions. Sealed Mil Spec. switches, sealed windows, a gasketed case and a printed circuit board with baked-on moisture and fungus resistant coating on both sides make this possible.
-
product
Digital Tank Test Kit
4109
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
product
Analog Tank Test Kit
4108
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
product
Model PS-1
16820-100
The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.
-
product
Data-logger
11275
Comes loaded with M. C. Miller’s Pipeline Survey software application for “Over-the-Pipe” Surveys:• Close Interval Potential Surveys (CIPS or CIS)• DCVG Surveys• Combined (single-pass) DCVG/CIS Surveys• Surface Potential Surveys