50 Ω High Voltage Pulse Generators
High Power Pulse Instruments GmbH (HPPI)
50 Ω High Voltage Pulse Generators by HPPI GmbH
-
product
High Voltage 50 Ω Pulse Generator
TLP-3010C
High Power Pulse Instruments GmbH
TLP-3010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±8 kV*High pulse output current up to ±30 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-4010C
High Power Pulse Instruments GmbH
TLP-4010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±10 kV*High pulse output current up to ±40 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010A
High Power Pulse Instruments GmbH
TLP-8010A - High Power Pulse Instruments GmbH
*Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010C
High Power Pulse Instruments GmbH
TLP-8010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester
HBM-S1-B
High Power Pulse Instruments GmbH
HBM-S1-B - High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm
-
product
±6 kV ANSI/ESDA/JEDEC HBM Test System
HBM-TS10-A
High Power Pulse Instruments GmbH
HBM-TS10-A - High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C
-
product
High Voltage 50 Ω Pulse Generator
TLP-12010A
High Power Pulse Instruments GmbH
TLP-12010A - High Power Pulse Instruments GmbH
- High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external pulse width extensions from 5 ns to 500 ns using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient software for system control and waveform data management- The software can control automatic probers for fast measurements of complete wafers- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
High Power Pulse Instruments GmbH
TLP-12010C - High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
product
High Voltage 50 Ω Pulse Generator for CMTI
CMTI-8010A
High Power Pulse Instruments GmbH
CMTI-8010A - High Power Pulse Instruments GmbH
The CMTI-8010A is a high voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17.
-
product
High Voltage 50 Ω Pulse Generator for CMTI
CMTI-8010C
High Power Pulse Instruments GmbH
CMTI-8010C - High Power Pulse Instruments GmbH
The CMTI-8010C is a high voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17.
-
product
JESD22-A115 Machine-Model (MM) Pulse Emulator
MM-10A
High Power Pulse Instruments GmbH
MM-10A - High Power Pulse Instruments GmbH
- Pulse unit to generate JESD22-A115 machine-model (MM) waveforms with TLP- Extremely stable and reproducible machine-model (MM) waveforms- Compatible with HPPI TLP-3010C/4010C/8010A/8010Csystems which have installed pulse width of 25 ns and rise time of 100 ps to 300 ps- Up to ±10 A machine-model peak current with TLP-3010C, which is equivalent to ±667 V (MM)- Up to ±15 A machine-model peak current with TLP-4010C, which is equivalent to ±1000 V (MM)- Up to ±30 A machine-model peak current with TLP-8010A and TLP-8010C, which is equivalent to ±2000 V (MM)- Same measurement procedure as TLP including DC test of the DUT- Compatible with HPPI TLP software and waveform data storage and management- 50 Ω SMA input and output connectors- Compact size: 61 mm x 25 mm x 17 mm
-
product
High Voltage 50 Ω Pulse Generator
TLP-3010C
High Power Pulse Instruments GmbH
TLP-3010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±8 kV*High pulse output current up to ±30 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-4010C
High Power Pulse Instruments GmbH
TLP-4010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Ultra fast 50 Ω high voltage pulse output with typical 100 ps rise time*Built-in HMM (IEC 61000-4-2) pulse up to ±10 kV*High pulse output current up to ±40 A*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns*Optional pulse width extender increases pulse width up to 1.6 µs in 68 programmable steps*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurement of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010A
High Power Pulse Instruments GmbH
TLP-8010A - High Power Pulse Instruments GmbH
*Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010C
High Power Pulse Instruments GmbH
TLP-8010C - High Power Pulse Instruments GmbH
*Wafer and package level TLP/VF-TLP/HMM testing*Combines TLP-8010A and TLP-4010C into one system*Can be operated together with TLP-8012A5 and TLP-3011C pulse width extenders*Ultra fast 50 Ω high voltage pulse output with typical rise time 100 ps (0-40 A) and 300 ps (> 40 A)*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω configuration*High pulse output current up to ±80 A (short circuit) with minimum 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 100 ps to 50 ns*8 programmable pulse widths: 1 ns to 100 ns (0-40 A), 1 built-in pulse width: 100 ns (> 40 A)*The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0-40 A)*Optional external pulse width extensions from 5 ns to 500 ns (> 40…80 A) using the external pulse width extender TLP-8012A5*Built-in pulse reflection suppression*Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
±6 kV ANSI/ESDA/JEDEC 2-Pin HBM Tester
HBM-S1-B
High Power Pulse Instruments GmbH
HBM-S1-B - High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) 2-pin tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, and 8010C hardware systems and software (upgrade on request)*Suppression of trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT voltage and DUT current sensor for real time voltage and current monitoring*Integrated DC test DUT switchIntegrated hardware 50 Ω trigger output for high speed digital oscilloscopesIntegrated overvoltage protection of voltage sense and DC test interfaces for oscilloscope and SMU protection during high voltage HBM testing*Fast and efficient HBM measurements including transient waveform data management using the HPPI TLP software*Compact size 145 mm x 82.5 mm x 44 mm
-
product
±6 kV ANSI/ESDA/JEDEC HBM Test System
HBM-TS10-A
High Power Pulse Instruments GmbH
HBM-TS10-A - High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C
-
product
High Voltage 50 Ω Pulse Generator
TLP-12010A
High Power Pulse Instruments GmbH
TLP-12010A - High Power Pulse Instruments GmbH
- High pulse output current up to ±120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical 300 ps rise time- Wafer, package and system level TLP and HMM testing- 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 digital programmable pulse rise times out of: 300 ps to 50 ns (optional)- 1 built-in pulse width: 100 ns- Optional external pulse width extensions from 5 ns to 500 ns using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient software for system control and waveform data management- The software can control automatic probers for fast measurements of complete wafers- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
High Power Pulse Instruments GmbH
TLP-12010C - High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
product
High Voltage 50 Ω Pulse Generator for CMTI
CMTI-8010A
High Power Pulse Instruments GmbH
CMTI-8010A - High Power Pulse Instruments GmbH
The CMTI-8010A is a high voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17.
-
product
High Voltage 50 Ω Pulse Generator for CMTI
CMTI-8010C
High Power Pulse Instruments GmbH
CMTI-8010C - High Power Pulse Instruments GmbH
The CMTI-8010C is a high voltage 50 Ω pulse generator for static and dynamic common mode transfer interference (CMTI) evaluations of digital isolators according IEC-60747-5-5 and IEC-60747-17.
-
product
JESD22-A115 Machine-Model (MM) Pulse Emulator
MM-10A
High Power Pulse Instruments GmbH
MM-10A - High Power Pulse Instruments GmbH
- Pulse unit to generate JESD22-A115 machine-model (MM) waveforms with TLP- Extremely stable and reproducible machine-model (MM) waveforms- Compatible with HPPI TLP-3010C/4010C/8010A/8010Csystems which have installed pulse width of 25 ns and rise time of 100 ps to 300 ps- Up to ±10 A machine-model peak current with TLP-3010C, which is equivalent to ±667 V (MM)- Up to ±15 A machine-model peak current with TLP-4010C, which is equivalent to ±1000 V (MM)- Up to ±30 A machine-model peak current with TLP-8010A and TLP-8010C, which is equivalent to ±2000 V (MM)- Same measurement procedure as TLP including DC test of the DUT- Compatible with HPPI TLP software and waveform data storage and management- 50 Ω SMA input and output connectors- Compact size: 61 mm x 25 mm x 17 mm