product
Elastomer Socket
As a structure made of silicon and conductive powder, elastomer is a good solution for high speed, no ball damage, stable CRES, low force and high frequency testing.
-
product
Abrasion Testers
Abrasion tester is used to determines the resistance of elastomers by the frictional loss of the rubber in products, such as tires, conveyor belts, hoses, footwear, floor covering etc.
-
product
Shore Durometer
UI-FT30
Shore Durometer is used to test hardness of rubber, thermoplastic elastomers, vulcanized rubber and other materials.
-
product
Stamped Spring Pin Sockets
Ironwood Electronics SBT sockets are small footprint sockets that are compatible with other product lines such as GHz elastomer sockets, Giga-Spring sockets, etc. The socket needs about 2.5mm extra space around the chip than the actual chip size utilizing only very small PCB real estate. A heat sink screw on the top provides the compression force as well as thermal relief and can be customized to dissipate more power. SBT socket uses SBT contact technology for high endurance and wide temperature applications. SBT Contact is a stamped contact with outside spring as well as inside leaf spring that provides a robust solution for Burn-in & Test applications. Solutions are available for 0.3mm to 1.27mm LGA, BGA, QFN, QFP, SOIC and other packages. Contact technology has 3 part system which includes top plunger, bottom plunger and a spring. The Beryllium Copper plungers are stamped and assembled to a stainless steel spring in an automated system to enable fast turnaround time, low cost and zero defects.
-
product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
Shore Hardness Tester
Beijing TIME High Technology Ltd.
A device used to measure the hardness of materials like rubber, plastics, and elastomers by measuring their resistance to permanent indentation.
-
product
MACRO IRHD System
Hildebrand Prüf- und Meßtechnik GmbH
Durometer Hardness System provides hardness readings on elastomers and plastics with a specimen thicker than 6 mm according to IRHD and Durometer hardness. It complies to international standards DIN ISO 48, ISO 48, ASTM D 1415 and DIN 53505.
-
product
Mass Flow Controller for Medium Flow
HFM-205 / HFC-207
The HFM-205/HFC-207, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-205 / HFC-207 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a full complement of fitting and elastomer options, the HFM-205/ HFC-207 covers a wide range of high flow applications.
-
product
6-Axis Robotic Automated Testing System
AT6
The Instron AT6 is a flexible, robot-assisted testing solution featuring six axes of motion, purpose-built to automate tensile, compression, flexural, and lap shear testing in alignment with widely used ASTM and ISO standards. Its modular design accommodates a broad array of materials—including metals, polymers, elastomers, films, composites, and sutures—at force capacities up to 600 kN. Capable of processing up to 500 specimens without operator intervention, the AT6 enables true unattended or “lights-out” operation, significantly increasing throughput around the clock. Optional modules include stations for specimen measurement, automated strain measurement, environmental temperature chambers, and multiple test frames for simultaneous testing. The system also integrates smoothly with auxiliary devices such as durometers, hardness testers, and surface roughness testers, making it a robust solution for high-volume, high-efficiency testing environments.
-
product
Harness Design and Manufacture
When designing an underwater cable harness, there are some factors which need to be considered, and we have produced the following list as a guide for customer information:Component considerations:- Electrical requirements- Mechanical considerations- Quality requirements- Reliability- Design redundancy (contact count)- Connector selection (type and form)- Locking requirements- Backpotting requirements- Waterblocking in moldings- Cable specification- Cable jacket material and compatibility with elastomers- Abrasion resistance- Stiffness profile at termination- Connector format (straight or right angle)- Molding format (straight or at an angle)- Clearance allowance for molding and cable routing- Elastomer compatibility (eg oil filled units)- Metalwork selection re: corrosion and cathodic delamination- Surface finish for metalwork as appropriateOperational considerations:- Operating depth profile (not just max. depth)- Tensile loads- Torsional loads- Bending loads- Bend control requirements (to limit bending at termination)- Deployment and recovery loads- Dynamic loading-Flow turbulence effects.
-
product
Fast Response Flow Controller for Medium Flow
HFM-301 / HFC-303
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Digital "A" Flow Controller for Medium Flow
HFM-D-305A / HFC-D-307A
Fast Response, Tight Accuracy!Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements.HFM-D-305A/HFC-D-307A mass flow instruments have flow ranges from 0-1000 slm to 0-2500 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Micro durometer
MD-1 Capa
High-precision measurement of micro-sized specimens with a Fully-automatic Micro Hardness IRHD System. simple operation. A hardness tester for thin and small specimens of various rubbers, thermoplastic elastomers, nonrigid plastics. Unlike conventional durometers, it enables direct measurement of the hardness of objects with higher reproducibility.
-
product
Reservoir Isolators
Fluid contamination can lead to high maintenance costs and downtime in hydraulic systems. Parker reservoir isolators provide protection against the ingestion of airborne contaminants such as dust, chemicals and water vapor through the breather-vent of your hydraulic system. Utilizing an elastomer bladder as a lung, the changes in gas volume in a hydraulic system's reservoir can be trapped and prevented from mixing with the outside atmosphere. Unlike conventional breather-vent filters, Parker reservoir isolators provide a positive separation without the possibility of clogging or need for maintenance.
-
product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
Long Travel Extensometer
XL
The Instron model XL (long travel) extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films. Designed for use with electromechanical testing instruments, Instron XL units can be used to measure specimens elongation's up to 10 in or 250 mm. An optional of 15 in or 375 mm travel is also available.
-
product
Digital "A" Flow Controller for Medium Flow
HFM-D-301A / HFC-D-303A
Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements.HFM-D-301A/HFC-D-303A mass flow instruments have flow ranges from 0-25 slm to 0-1000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Low Pressure Drop Thermal Mass Flow Meter
HFM-200 LFE
The HFM-200 LFE Series by Teledyne Hastings can be configured and accurately measure gas flow in a broad array of applications. Featuring reliability and stability, the 200 Series is chosen by users for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow meter compatible with most gases.The HFM-200 LFE meter has flow ranges from 0-10 sccm to flows of 0-15,000 slm; provides analog outputs, and is constructed of stainless steel. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Cleaning for oxygen service is available. Our laminar flow elements (smooth, threaded or flanged) are available in various sizes from 3/8" up to 8". Low pressure drops at full scale flow.
-
product
High Performance UV Nanoimprint Resist
AMONIL®
UV Nanoimprint is a mechanical molding technique. A template made from quartz or a flexible elastomer with a 3D relief is brought into intimate contact with a UV-curable resist spin-coated on top of a substrate. Applying low imprint pressure at room temperature features are filled within seconds due to the low viscosity of the imprint resist. The resist is hardened via UV-light through the backside of the template. Finally substrate and template are separated. The replicated resist relief can further be transferred into the substrate via RIE-process or used as functional element.
-
product
Socket Accessories (Lid Options)
GHz elastomer, spring pin and other socket technologies can accommodate different lid options depending upon the application requirement. Typical choices are swivel-lid, clamshell, double-latch, integral heatsink, etc. Custom lid solutions are also available.
-
product
Shore Hardness Tester
HT-6510
Application: shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like substances such as neoprene, silicone, and vinyl. It can also be used for soft plastics, felt, leather and similar materials. Shore D is designed for plastics, Formica, Epoxies and Plexiglass. Application: shore C is designed for various foam and sponge.
-
product
Digital "A" Flow Controller for High Flow
HFM-D-306A / HFC-D-308A
Mass flow techniques provide reliable, repeatable and accurate gas flow rate measurements.HFM-D-306A/HFC-D-308A mass flow instruments have flow ranges from 0-2500 slm to 0-10000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Fast Response Flow Controller for Medium Flow
HFM-305 / HFC-307
The HFM-305/HFC-307 is Teledyne Hastings' fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen for its fast response under a wide range of conditions. .The HFM-305 / HFC-307 meters and controllers have flow ranges from 0-1000 slm to flows of 0-2500 slm; provide analog outputs, are constructed of stainless steel and can be configured to have either normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-305 / HFC-307 services a wide variety of applications. Cleaning for oxygen service is available.
-
product
Solderable Individual Conductive Elastomer Pin
The World’s First Solderable, Individual Conductive Elastomer Pin
-
product
Silver Ball Matrix Sockets
SM Contact is a unique contact that has precise silver balls held together by a proprietary conductive formulation. These conductive columns (diameter optimized for 50 ohm impedance) are suspended in a non-conductive flexible elastomer substrate with a patented solid core for enhanced durability and reliable performance over time, temperature and cycles. This flexible substrate is very compliant and resilient and enables the conductive columns to revert back to original shape when the force is removed. Solutions are available for 0.25mm to 1.27mm LGA, BGA, QFN, CSP, POP, WLP and other packages. The silver ball matrix contact technology is also available with a protective plunger matrix (a gold plated copper cylinder) that sits on top of the conductive columns. This plunger matrix protects the conductive column from contamination from various solder ball interfaces. A quickly replaceable plunger matrix enables minimal downtime during final production test. The product family code for this line of sockets is SMP.
-
product
Solar Radiation (Sunshine) Test
This test determines the effects of direct solar radiation on components and material. The heating effects of solar radiation differ from those of high air temperature in that the amount of heat absorbed depends on the roughness and color of the surface on which the radiation is incident and the angle of incidence to the sun. Variations in the intensity of solar radiation over the surface of the component, may cause components to expand or contract at different rates, which can lead to severe stresses and loss of structural integrity. In addition, degradation due to photo-chemical changes can occur such as fading of color, deterioration of natural and synthetic elastomers and polymers. The test items that are subjected to solar radiation testing are those that are exposed to solar radiation during its life cycle, in the open, in warm climates.
-
product
Open Top BGA Sockets
Ironwood has the most comprehensive collection of open top BGA and QFN sockets that can be used for qualification application, silicon FIB testing, system development, thermal characterization, burn-in application, etc. IC socket can be defined as an electromechanical device, which provides removable interface between IC package and system circuit board with minimal effect on signal integrity. Typical packages include BGA, LGA, QFN, QFP, WLCSP, etc. Open top allows access to the top side of IC. Below is an example BGA socket that uses low cost elastomer contact technology.
-
product
Din Abrasion Resistance Tester
SG-P01D
This tester is used to determine the abrasion characters of elastomers, rubber, soft synthetics, leather. etc or is with characters of high efficiency, good reproducibility and easy operation.
-
product
Automatic Contacting Extensometry
AUTOX750
The Instron AutoX750 automatic contacting extensometer offers automated, high-precision strain measurement by motor-driven contact arms to engage specimens—eliminating manual setup while maintaining sub-micron accuracy over long travel. They integrate seamlessly with Instron testing frames and software to reduce operator error, speed cycle times, and ensure repeatable, standards-compliant strain data for metals, plastics, composites, and elastomers.