VDE
Verband der Elektrotechnik
-
product
Two-Pole Voltage Tester According to DIN EN 61243-3 (VDE 0682-401)
PeakTech Prüf- und Messtechnik GmbH
Two-pole voltage testers, are ideal for quick and uncomplicated voltage measurements.
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
IP code Testing
Educated Design & Development, Inc.
Complies with various IEC, EN, CE, VDE, UL & CSA requirementsUnit comes with NIST traceable / ISO 17025 accredited certificate of calibration.ED&D is ISO 17025 accredited by ACLASS, an ILAC Member. Measurement data and uncertainty data is available.Uses RTS-01 Rain Spray Head
-
product
KPG 24kV VLF Test Set
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
product
Socket-Outlet Torque Balance
CX-L12
Shenzhen Chuangxin Instruments Co., Ltd.
For measuring and testing the torque strain exerted by appliances with plug pins on socket-outlets in accordance with IEC 60065/1998-07 § 15.4.1 Fig. 11, IEC 60335-1 / 1991-04 § 22.3, IEC 60884-1 / 1994-06 § 14.23.2, EN 60335-1/1994 + A11 /1995 § 22.3, EN 60950/1992 + Amendments up to 1997-03 § 4.3.18, VDE 0700 Part 1 /1995-10 § 22.3, VDE 0805/1997-11 § 4.3.18
-
product
Rotary Field Direction Indicator According to DIN EN 61557-7 (VDE 0413-7)
PeakTech Prüf- und Messtechnik GmbH
Direction indicators are indispensable for use in the electrical assembly of three-phase motors. This offers two different functions for displaying the direction of rotation. I
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
Standard Gain Horn Antenna
SAS-586
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
product
IEC60335 Inclined Plane Test Table for Stability Test
CX-W600
Shenzhen Chuangxin Instruments Co., Ltd.
It's to determine the stability of electric appliances which are used on a table or on the floorin accordance with IEC 60065 / 1998-07 clause 19.1, IEC 60335-1 / 1991-04 clause 20.1, IEC 60601-1 /1988 clause 24.1, IEC 60950 / 1991 + Amendments, modified, clause 4.1.1,EN 60335-1 / 1994 and A11 / 1995 clause 20.1, EN 60950 / 1992 + Amendments up to 1997 clause 4.1.1,VDE 0700 Part 1 / 10.95 clause 20.1 and Part 3 / 3.96 clause 20.1, VDE 0730 Part 1 / 3.72 clause 20a,VDE 0805 / 11.97 clause 4.1.1Inclined Plane Device is used to test the stability of an apparatus that requires a surface in order to work.The device cosist of a surface and an angle adjusting device with 0- 15 °
-
product
Voltmeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.
-
product
Dipole Antennas
Provides reliable, repeatable measurements. Suitable of FCC, MIL-STD, VDE, Tempest and Immunity stesting.
-
product
Partial Discharge Meter
TMG
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
product
Ammeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
Is a measuring device for AC and DC currents up to 1000 A using a current clamp for conductor diameters up to 48 mm. Current and voltage measurements are carried out as true RMS (true rms value) measurements, which means that the measured values are displayed correctly even with waveforms that deviate from a sine wave.
-
product
BSV Systems
In the medical field, electrical devices are used on which people's lives or healing processes depend. The highest demands are therefore placed on the devices required in the operating room or intensive care unit. Gustav Klein BSV systems guarantee an uninterrupted and safe power supply in accordance with VDE 0100 and ÖVE/ÖNORM E 8007.
-
product
High Voltage
Accurate measurement of high voltages acc. to VDE 0432 und IEC 60060 in conjunction with a high voltage divider.For the measurement, the principle of capacitive or resistive divider is used, which can be selected in the peak voltage meter.
-
product
General Power Relays
Panasonic Industrial Devices Sales Company of America
2A and greater load rating in Polarized, Non-Polarized, High Capacity DC, General Purpose, and Safety configurations. UL, CSA, C-UL, TUV, VDE, and SEMKO certifications.
-
product
Resistance Measuring Device According to DIN EN 61557-4 (VDE 0413-4)
PeakTech Prüf- und Messtechnik GmbH
An extremely robust milliohm measuring device in a splash-proof hard case for professional field service use, e.g. for resistance measurement on motor coils, generators and transformers or for continuity testing on ring bus systems in industrial plants.
-
product
PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit
APCI-3501-8
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
product
Electrical Safety Testers- Hipots
Safety testers (also named hi-pot tester/hipot tester/hipot test) are designed to ensure safe operation of DUTs under various operating conditions and environment.GW Instek’s GPT-9900/GPT-9800/9600 series safety testers(hipot test) provide safe and quick measurement tools for AC/DC withstanding voltage tests, insulation resistance tests, and AC ground bond tests. Those tests are required by many international safety regulations such as CE, UL, VDE, and etc. We also have leakage current tester, GLC-9000, which supports all the major leakage current test standards for medical and general electronic equipment.
-
product
12.5 mm Test Sphere Probe
CX-12.5
Shenzhen Chuangxin Instruments Co., Ltd.
The rigid sphere (12.5 mm) from Autostrong is designed and manufactured to perform the test specified in many standards (IEC 60335, IEC 60065, IEC 60745, IEC 61029, IEC 60950) to prove the degree of protection for the first characteristic numerals 2 (IP2X) .Its is designed to meet the requirements of international safety regulatory agencies such as UL, DNV, IMQ, BVSQ, ITS, IRAM , CSA, VDE, DIN , INMETRO.
-
product
Insulation Measuring Device According to DIN EN 61557-2 (VDE 0413-2)
PeakTech Prüf- und Messtechnik GmbH
This digital insulation measuring device is required for various measurements of cables, components and their insulation.
-
product
Valve Position Sensors
*Dual inductive sensor for pneumatic actuators and valves*Designed for simple fit to common actuators based on VDI / VDE 3845*Quick and easy installation of the AS-i dual sensor*Position feedback for rising stem valves with up to 80 mm stroke*Reliable permanent valve monitoring
-
product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
product
Earth Meter
EM-4055
The EM-4055 Earth Meter is a digital, microprocessor-controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is well suitable to measure earth systems in power substations, industries, distribution networks, etc., according to VDE 0413. It is also suitable for soil resistivity measurements, in order to optimize the earth systems project
-
product
Biconical Antennas
For many years most standards called for the use of a half-wave dipole antenna set for frequencies above 80 MHz. However, to reduce test time, broadband antennas such as the biconical antenna and log periodic antennas began to be accepted. Broadband antennas, compared to half wave dipoles, reduce test time because the technician did not have to stop the test to adjust the dipole antenna for each frequency. A.H. Systems'' 7 models of Biconical Antennas operate efficiently over the frequency range of 20 MHz to 18 GHz. Suitable for FCC, MIL-STD, VDE, TEMPEST, and immunity testing, each Biconical antenna will provide reliable, repeatable measurements.
-
product
[5kV AC/6kV DC] Hipot and Insulation Resistance Tester, Rise/Fall-Time Control Function Equipped
TOS5300 Series
The "TOS5300 Series" is a series of test instruments used in Hipot (withstanding voltage) tests and insulation resistance tests, two of the four tests regarded as necessary for ensuring the safety of electrical products. With an output of 5 kV/100 mA (AC) and 6 kV/10 mA (DC), the series can be used in Hipot (withstanding voltage) & insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards and the Electrical Appliance and Material Safety Law. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a new low-cost standard model that provides thorough operability, reliability and safety.
-
product
Single, Double Power Cord Tester
LX-30A+
Shenzhen Lian Xin Technology Co., Ltd.
Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards ..·used to test single – ends ,double –ends ,three-ends power supply cords..·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,.·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,
-
product
Earth Resistance Tester
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.





























