Filter Results By:
Products
Applications
Manufacturers
CISPR
Comité International Spécial des Perturbations Radioélectriques (Special international committee on radio interference).
-
product
5uH Line Impedance Stabilisation Network LISN - CISPR 25
TBOH01
The TBOH01 5H LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.
-
product
Absorber Lined Shielding Enclosure Measurements
ALSE
Due to on-going work in the standardization committee CISPR D (responsible for CISPR 25) the latest issue CISPR 25 Ed. 4.0 has not been cited to-date. In the meantime we are able to offer two different validation procedures:
-
product
RFI Power Emission
AFJ receivers and accessories for the disturbance power using the absorbing clamp measurement, are conforming to CISPR 16-1-1 and CISPR 14-1.
-
product
Absorbing Clamps
The Absorbing Clamp was designed to measure the disturbance power according to CISPR 16-2-2 in the frequency range 30-1000 MHz, it complies to the technical requirements of CISPR 16-1-3.
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Measurement
Ambient Noise
The Ambient Noise (AN) measurement is done in accordance with CISPR 22 and EN 50022
-
product
Radiated Emission
High accuracy CISPR 16-1-1 EMI receivers and high precision calibrated antennas for radiated emission measurements.
-
product
3-Dimensional Loop Antenna Van Veen
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15
-
product
Validation
Table Influence (TI)
The Table Influence (TI) is measured according to CISPR 16-1-4 in the frequency range 200 MHz 18 GHz.
-
product
Normalised Site Attenuation
NSA
Normalised Site Attenuation (NSA) is measured in accordance with CISPR 16-1-4 and ANSI C63.4 in semi and fully anechoic environment.
-
product
Biconical Antennas
Biconical antennas are used for emissions and immunity testing to meet various EMC standards specified by FCC, CISPR and EN. The broadband characteristics of the biconical antenna make it a good choice for making sweep measurements and for automated measurement systems.
-
product
Active Loop Antennas / Magnetic Field Probes
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
product
Test Services for EMC Compliance and Safety
Parker Chomerics offers a wide variety of EMI/EMC and safety testing for regulatory compliance. Tests include FCC, EC, VCCI, IEC 1000 (formally 801) EN 61000 Series, CISPR, Austel, MIL-STD-461 and EU regulations
-
product
Current Probes
Com-Power's Current Injection Probes are used for RF conducted immunity testing per IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160 and MIL-STD 461. Current injection Probes are to be used only when there is no commercially available CDN for the type of port(s) to be tested.
-
product
Calibrators
Power Diagnostix calibrators enjoy all the advantages of 20 years' experience in calibration services. The broad range of easy-to-use and robust units for many different applications ensures reliable PD measurements compliant to international standards, such as IEC 60270, CISPR 18-2, and NEMA 107-1987.
-
product
EMI Test Receiver
SER
Saluki SER series EMI receivers comply with CISPR 16-1-1 standard, integrated CISPR-AVG, CISPR-RMS, QPK detectors, and electromagnetic interference measurement. According to CISPR, EN, FCC and MIL standards, which is suitable for EMI testing in home appliances, lighting, automotive electronics, medical, and other industries. Combined with ETR PC measurement software and a wealth of test options, accurate automated testing is possible. The whole system is equipped with a spectrum analysis module and a tracking signal generator to meet the testing needs of users in different fields.
-
product
EMC- EMI test Equipments
Our AFJ FFT 3100 & 3300 EMI Receivers cover the full frequency range from 9kHz to 3GHz.To allow a greater flexibility GTemCell can provide either a single or multiple solution of receivers to cover the most common standards and regulations such as CISPR, EN, IEC, FCC etc.
-
product
Antenna Calibration
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
product
TDK Test Services
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
product
Line Impedance Stabilization Networks
LISN
LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.
-
product
Line-impedance stabilisation network
NNB 21 set
The NNB 21 line impedance stabilization network is designed for measuring of grid bound interferences of a device under test according to the satndard CISPR 25/ISO 7637. It measures the RF interference, which couples into the vehicle electrical system. Measurements during the development in a frequency range from 100 kHz to 1GHz can be carried out.
-
product
Calibration
EMC Test Antennas
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
product
EMI64k Automation Software Suite
The EMI receiver families TDEMI® of GAUSS INSTRUMENTS® provide a huge fully CISPR compliant real-time bandwidth and therefore allow to speed up your measurements tremendously and to reduce the measurement uncertainty significantly - both at the same time. By using the full automation software suite EMI64k from GAUSS INSTRUMENTS the test procedures according to the CISPR 16-2-3 standard for the FFT-based measuring instruments as well as conventional testing (pre-scan and final maximization) and further EMC Standards are available. In comparison to the previously conventional pre-scan and final measurement strategy, the overall test quality can be significantly increased whereas the testing times are reduced by orders of magnitudes.
-
product
Measurement
Site VSWR
The Site VSWR measurement is done according to CISPR 16-1-4 in the frequency range from 1 GHz to 18 GHz using broadband omni directional antennas in horizontal and vertical polarisation. The volumetric test method is applied (test volume needs to be specified), test distance 3 m - any other distance upon request. The ground plane has to be covered with absorbing material.
-
product
EMI Measurement Application
Fsx-k54
The EMI precompliance application (K54 option) for Rohde & Schwarz signal and spectrum analyzers is the ideal extension for EMI analysis during product development and to prepare for a smooth product certification process. Typical fields of application include commercial, automotive, avionic and military product developments (CISPR, EN, FCC, DO-160 and MIL-STD-461 standards).
-
product
Test Equipment Calibration
EMC Technologies can provide convenient, local, NATA accredited calibration services which greatly reduces lead time and costs for EMC test equipment. In the past these items had to be sent overseas or to expensive government laboratories. We can calibrate these items against common standards such as CISPR 16 (and subparts), IEC 61000-6-X series, ANSI C63.4, ANSI C63.5 and ARP 958.
-
product
Automotive EMC Testing
Having been assessed by Ford Detroit’s EMC expert, we are Australia’s only Ford (and NATA) accredited automotive EMC test laboratory. Others have tried, but none have succeeded. Ford does not accept reports from EMC labs that are not on the Ford list of accredited labs. The scope ranges from component to complete vehicle level EMC testing for Australian and overseas manufacturers. We also have a fully dedicated CISPR 25 Electronic Sub Assembly (ESA) chamber, another large CISPR 25 anechoic chamber for vehicle testing or susceptibility levels in excess of 500V/m. We possess a vast array of specific automotive EMC test equipment such as BCI’s, tri-plate’s, and striplines for susceptibility and emissions testing to meet the most stringent automotive EMC requirements. Our Australian and overseas customers use our labs because they know that our reports will be accepted and will not be questioned.
-
product
EMI Test Receiver
ESW
With its outstanding RF characteristics, high dynamic range and measurement accuracy, the R&S®ESW is the best choice for fast and reliable certification measurements. It meets the most stringent requirements in line with CISPR, EN, MIL‑STD-461, DO‑160 and FCC. The R&S®ESW captures and weights disturbance spectra very fast with its FFT based time domain scan. The real-time spectrum analysis with spectrogram function permits detailed analysis of even the shortest disturbance signals. MultiView mode delivers a simultaneous display of results from multiple operating modes for best instrument usability.
-
product
EMC Test System
An electric product might cause the malfunction to other electric appliances by discharging the emission noise from it, or is oppositely caused the malfuction by the emission noise from other electric appliances. The former is checked by the EMI test and the latter is checked by the EMS test. The international standard like the CISPR standard is provided so that such an accident should not happen, and the manufacturer must declare by themselves beforehand that their product meets the standard. The generic name of the EMI test (Electro-Magnetic Interference) of the emission measurement and the EMS test (Electro-Magnetic Susceptibility) of the immunity