Filter Results By:

Products

Applications

Manufacturers

Capacitance

measured in farads the amount of stored charge.

See Also: Capacitance Bridges


Showing results: 1 - 15 of 520 items found.

  • Capacitance Manometers

    MKS Instruments

    Capacitance Manometers

  • Capacitance Meter

    E4981A - Keysight Technologies

    The E4981A capacitance meter offers a high-speed with reliable measurements for ceramic capacitor testing in the production lines. The E4981A realizes the measurement capabilities of capacitance from small to large values with accurate measurements. The E4981A capacitance meter contributes improvements of the test throughput, while attaining excellent component quality for ceramic capacitor testing.

  • Capacitance Meter

    Shenzhen UYIGAO Electronic Technology Co., Ltd

    Inductance capacitance meter is a kind of stable performance, safe and reliable, high precision of handheld 3 1/2 a manual switch range digital instrument. Can be used to measure the capacitance, resistance, triode magnification beta and other functions

  • Capacitance Standard

    SCA Series - IET Labs

    The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.

  • Capacitance Tester

    LCR55A - Amprobe Test Tools

    The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes.

  • Capacitance Bridge

    Guildline Instruments Ltd

    Capacitance Bridge is an instrument employing the AC Current Comparator principle. The 9910A is a versatile instrument for a wide range of applications including capacitance measurements, cable testing, corona loss measurements, insulator and dielectric testing, inductance measurements, potential transformer error measurements, shunt reactor loss measurements and power transformer testing.

  • Capacitance Bridge

    1620 - IET Labs

    The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.

  • CAPACITANCE METER

    C350 - GME Technology

    This is a high quality digital capacitance meter. Check the accuracy and status of capacitors up to 20mF, a very handy tool for virtually any technician. It features high accuracy (0.5%) and 9 selectable ranges. A zero adjustment knob is also provided to "zero" test lead capacitance. Includes test probe set and yellow rubber boot.

  • Capacitance Meter

    Changzhou Applent Instruments Inc.

    It is a piece of electronic test equipment used to measure capacitance, mainly of discrete capacitors. Depending on the sophistication of the meter, it may display the capacitance only, or it may also measure a number of other parameters such as leakage, equivalent series resistance (ESR), and inductance. For most purposes and in most cases the capacitor must be disconnected from circuit; ESR can usually be measured in circuit.

  • Capacitance Bridge

    1621 - IET Labs

    The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.

  • Capacitance Tester

    ZHANGZHOU HUAYI ELECTRONICS CO.,LTD.

    Is a piece of electronic test equipment used to measure capacitance, mainly of discrete capacitors. Depending on the sophistication of the meter, it may display the capacitance only, or it may also measure a number of other parameters such as leakage, equivalent series resistance (ESR), and inductance. For most purposes and in most cases the capacitor must be disconnected from circuit; ESR can usually be measured in circuit.

  • Capacitance Bridge

    TCB-108 - Criterion Instruments Limited

    Model TCB-108 - Capacitance Bridge is a general purpose bridge for measurement of capacitors, capacitance of transformers and dielectric material. It comprises a transformer-type bridge operating from an internal 108 Hz generator(for accurate measurement at 60Hz) with digital readout of capactiance from 1 pF to 99.999 pF over four ranges and digital readout of D (dissipation factor) in percentage from 0-50%.

  • Capacitance Sensors

    Accumeasure Series - MTI Instruments

    The Accumeasure product line features capacitive sensor products for high resolution gap and displacement measurements that require a high level of accuracy that is both stable and repeatable. A capacitive sensing system consists of a probe and amplifier. Capacitive measurements can be performed in a multitude of environments using non-contact passive capacitance probes that are not affected by magnet fields, temperature, humidity, nuclear radiation, and pressure. This is largely due to the nature of the rugged and passive capacitance probes.

  • Capacitance Manometer

    VG-200S - HORIBA, Ltd.

    Absolute pressure measurement is crucial for most of vacuum processes in various industries including Semiconductor, FPD, HDD, PV and Coating. A capacitance manometer determines the total pressure from the deformation of the diaphragm that occurs when a pressure difference is applied to both side of the diaphragm.

  • Capacitance Standard

    GenRad 1417 - IET Labs

    The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.

Get Help