Disturbance Recorder
APR64
This equipment analyzes and records in real time from 0 to 96 analog channels and from 0 to 1536 digital channels. The APR64 equipment is a system that is completely modular and scalable by adding drawers (digital channels and local and/or remote analog channels by fiber optic, relay, synchronization)
-
product
Three Phase Voltage Disturbance Recorder
PQR 2020
The PQR 2020 is a Three Phase Voltage disturbance detector and recorder. This device is designed to be connected to a single phase 120V or 240V AC line or a Three Phase 208/240/480 Volt AC line and will monitor these lines for voltage disturbances.
-
product
Single Phase Powerline Monitors
a Voltage disturbance detector and recorder. This device is designed to be plugged into a 120V or 240V AC line and will monitor this line for voltage disturbances and temperature or Humidity variations.
-
product
Multi-Function Transient Fault Recorder
TR-3000
The TR-3000 is the only tool you need to capture and diagnose power system anomalies. With multiple recording modes and continuous transient oscillography, you will never miss an event. The TR-3000 captures high speed transients and long term system disturbances with enough memory to give you a complete view of the system disturbance. The TR-3000 takes the place of several devices: • Fault and Disturbance Recorder • Transient Fault Location • Phasor Measurement Unit • Power Quality Monitor • Sequence of Events Recorder.
-
product
Electrical Network Analyzer
Portable disturbance recorder APR64P with its accessories Allows monitoring of 8 or 16 analog channels and 3 to 32 digital channels.
-
product
IDM+
Multi-functional fault recorder including: -- Disturbance fault record (DFR)- Dynamic disturbance recording (DDR) - Phasor measurement unit (PMU C37-118)- Power Quality (PQ Class A)- Travelling wave fault location (TWS to +/-60m) - Impedance fault location- Protocols (61850, Modbus, DNP3) - Sequence of event recording (SOE)- GPS, IRIG and NTP time sync- iQ+ masterstation software.
-
product
Power System Recorder with CDR , PMU and IEC 61850 station bus protocol
TESLA 4000
ERLPhase Power Technologies Ltd
The new TESLA 4000 is an intelligent, state of the art, user-friendly multi-timeframe dynamic power system recorder with advanced Phasor Measurement Unit (PMU) and Continuous Disturbance Recording (CDR) capabilities. Wide area swing recording accomodates system performance analysis in minutes Meets NERC continuous disturbance recording standards with non-volatile on board flash memory No mechanical moving parts – flash drive eliminates most common mode of failure in recorders. Each flash drive holds 1000 records. IEEE C37.118-2005 SynchroPhasor Standard
-
product
Digital Fault Recording
SHERLOG
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.
-
product
Multifunction Data Collection and Analysis System
2002
The Model 2002 DME System is a state of the art, multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.
-
product
Multifunction Data Collection and Analysis System
9000
The Model 9000 DME System is a high performance multifunction data collection and analysis system. It is suitable for application in an electrical utility substation or plant environment to produce Sequence of Event (SER), Digital Fault Recorder (DFR), Dynamic Disturbance Recorder (DDR), and Continuous Recorder data in conformance with PRC-002-1 and PRC-018-1. All data recorded by the DME system is stored in IEEE C37.111 format and named in conformance with IEEE C37.232. The system also has a software option to enable the Phasor Measurement Unit (PMU) feature to provide streaming data in conformance with IEEE C37.118.
-
product
Multi-Function Recorder
Platinum 2.5K
For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.
-
product
Power Quality Analysers
EPPE
Power quality measuring systems with integrated fault recorder functionality for continuously and automatically monitoring electrical installations at all voltage levels. The measuring systems of the EPPE series continuously and precisely record all the electrical parameters of the power supply. They deliver detailed quality evaluations which reveal even the smallest of deviations and contribute to identifying the cause of disturbances.
-
product
Multi-Function Recorder
TR-2000
For all types of power system events, the TR-2000 Multi-Function Recorder provides all the information you need to capture the complete picture. With the true integrated functionality of the TR-2000, you have one place for all your answers. Simultaneously perform: transient recording, disturbance recording, phasor measurements, power quality analysis, and sequence of events recording.
-
product
Portable Multi-Function Recorder
Platinum 2.5K/Portable
The Platinum 2.5K Portable Multi-Function Recorder is packaged in a rugged case with quick connect interfaces for fast and simple field connection. Interface cables are provided with shrouded banana jacks that couple easily with a variety of measurement CT’s and voltage scaling devices offering complete flexibility for power utility and industrial use. The Platinum 2.5K Portable Multi-Function Recorder utilizes a 40GB solid state drive that eliminates the need for a mechanical hard drive and stores over 1,000 fault and disturbance records at once. It meets regulatory compliances including PRC-002-2.
-
product
GOOSE Message Recorder
TR-61850
Whether a new or existing installation, AMETEK’s TR61850 adds the capability to easily monitor and record GOOSE messages within the substation. All data from the fault recorders and TR61850 automatically merge providing a single point of reference when analyzing transient events and system disturbances. With a wide range of time synchronization, communication options and small form factor, the TR61850 seamlessly integrates into any application.Configuration of the GOOSE Message subscriptions is quick and easy with AMETEK’s configuration tool. Using the IEC61850 Substation Configuration Language (SCL), third party IED Capability Description (ICD) files are imported and subscriptions are created by simply dragging and dropping available GOOSE message outputs.