Filter Results By:
Products
Applications
Manufacturers
- LBA Group, Inc
product
Static & Lighting Chokes
Lighting chokes are used to pass tower lighting voltages across the base insulator of a series-fed tower without appreciably altering the tower impedance. LBA TC-300 general purpose tower lighting chokes are provided for three wire 110/220 VAC circuits. Maximum current is 25 amps. These chokes are rated for peak base voltages to 10,000 volts, and present a typical reactance of +j5000 ohms at 530 kHz. Bypass capacitors are provided on each winding.
-
product
Fiber Optic Temperature Sensor with the EasyDisk
The TPT-62
The TPT-62 fiber-optic temperature probe family employs industry standard 62.5µm core OM1 fiber optic for highly improved optical, mechanical, and reliability properties over legacy 200 µm core (1st generation) fiber optic sensors. The EasyDisk sensor tip assembly ensures IEC60076-2 (Annex E) compliant installation and enables quick insertion of the probes into the spacers within the windings of transformers.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
High Voltage Insulating Diagnosis Systems
DAC-6017
It can measure and diagnose the insulating characteristic of winding coils of high voltage electric motor, generator, and etc.It also makes possible to build in-vehicle type or stationary type in accordance with the application.
-
product
Insulation Tester
61-797
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
product
Insulation Tester, 250/400/1000V
61-795
*Checks new installation for damaged insulation*Checks existing installations and motor windings for breakdown in insulation*2-year warranty
-
product
Megohm Meter
Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.
-
product
Micro and Milliohmmeter
AD-7110
The instrument AD-7110 is designed to measure, with high accuracy, resistance conductive elements of power devices: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of screw connections, crimp, welded state of the contacts of switches and relays current up to 100 A .
-
product
Micro and Milliohmmeter
AD-7010
AD-7010 instrument is designed to measure, with high accuracy, the resistance of conductive elements power equipment: motor windings, transformer windings, conductor rails, inspecting the electrical conductivity of bolted joints, crimped, welded, the contacts of switches and relays.
-
product
Motor/Generator Test Equipment
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
product
Motor Starting & Control Resistors
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.
-
product
Multi-Channel, Programmable Current Source
CS-48-100
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
product
Ocean Signal RescueME PLB1 (Personal Locator Beacon)
RescueME PLB1
The RescueME PLB1 is the world's smallest 406mhz & GPS enabled PLBOperation of the rescueME PLB could not be simpler. To activate the PLB: Pull the retractable antenna out by its end tab, flip open the spring loaded cover over the activation button, hold the button for 1 second until the lights blink. Visual instructions are clearly printed on the case. When activated, the rescueME PLB1 will transmit accurate position data from its 66 channel GPS for a minimum of 24 hours while the integrated strobe light ensures maximum visibility.Ocean Signal has ensured that rescueME, like all of its other safety products, exceeds statutory requirements. RescueME PLB provides an incredible 7 year battery life, and is covered by a 7 year warranty. Even after more than 24 hours of continuous operation, and when the battery power is insufficient to transmit the satellite signal, the PLB1's homing beacon and strobe light will continue to operate. This high intensity strobe light features a molded lens to enhance the visibility of its efficient LED and it gives a powerful 1 candela light emission.Self-test of the PLB can be carried out with a simple button press with the start of test and results clearly indicated by a green flashing light. The antenna is easily extended like a normal tape measure and can be retracted using the winding mechanism on the top of the unit. This unique feature greatly facilitates user training and familiarization as it is not a one time deployable antenna similar to existing PLBs.rescueME comes with a snap-in mounting bracket and universal rubber mounting strap which can be fitted permanently or with each use. It is also supplied with a detachable flotation lanyard to accommodate all scenarios out of the box.
-
product
Potential Transformer Test Set
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
product
Resistance Measuring Equipment
measure coil winding resistance of motors, transformers, etc, under energizing AC voltage. The direct reading is possible with 4-wire measurement method, and temperature of specimens is immediately calculated from measured resistance values and displayed. Ambient temperature is automatically taken in by connecting an option sensor Model DAC-PT-100.
-
product
RF Inductors
LBA Technology "Blue Line" RF inductors are based on over 30 years of proven international performance. Blue Line inductors are unsurpassed for hi-Q, stability, and low RF losses. These inductors are manufactured from heavy silver plated copper conductors and brass fittings, treated to resist tarnishing. Windings are insulated with melamine or G-1 0 epoxy laminates. These materials are recognized for their exceptional RF qualities, arc resistance, mechanical strength, and low moisture absorption. Supporting frames are engineered to permit maximum access to windings for convenience in adjustment. The metallic frames are separated by insulators to prevent induced current flow.
-
product
Separating Transformers
Is a transformer in which the primary and secondary windings are galvanically/electri- cally separated with basic insulation. Isolating transformer: A separating transformer with a protective partition between the primary and secondary windings.
-
product
Speed Pick-up
SU63
The Validyne SU63 is an AC inductive speed pick-up used for RPM measurement on high-speed rotating equipment. The SU63 is a tightly-wound coil with a laminated core that can be conveniently mounted on rotating equipment so that the magnetic field of a magnetized nut or part passes through the coil windings. The moving magnetic field produces a voltage within the coil proportional to its rate of change and the strength of the permanent magnetized part. The frequency of this inductive voltage spike is fed into an oscilloscope or counter to determine RPM.
-
product
Standard CT
6300A
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
product
STDETransformer Demagnetizer
STDE
This option allows neutralizing the residual magnetization of the power transformer core after the winding resistance test. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.
-
product
Sweep Frequency Response Analyzer
M5400
The M5400 sends an excitation signal into the transformer and measures the returning signals. Comparing this response to baseline readings and results from similar units allows you to identify deviations and confirm internal mechanical problems.The M5400 reduces the uncertainty about apparatus condition by providing solid evidence of mechanical integrity or winding movement. Use it to help determine how a transformer is deteriorating, if it can go back in service after a fault or if it has been damaged during transit.
-
product
Switch Module
STCS
The external module STCS allows performing automatically the following PT tests: ratio per tap; winding resistance; OLTC dynamic test. The connection to the transformer under test, to STS and to the measurement taps is performed just once; then, all transformer tests are performed without interruptions.
-
product
Tap Changer Analyzers & Winding Ohmmeters
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
product
Toroidal Turns Analyzer
1000
International Electro-Magnetics, Inc.
The Model 1000 is designed to be used in production environments to test for actual turns on toroidal cores. It is able to test single winding toroids as well as multiple windings. It automatically compensates for variations in core permeability.
-
product
Transformer Ratio Meter
TRM 1000
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
product
Transformer Winding Resistance Meter
10A
*10A DC continuous current in 4 ranges of 0.01A, 0.1A, 1A and 10A.*4 ½ digit display for higher resolution.*Dual channel measurement.*Suitable for operation in energized switchyard conditions.*Specialized protection circuits for suppression of inductive voltage kickback.*SMPS based - lightweight and portable.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Transformer Winding Resistance Meters
Vanguard Instruments Company, Inc.
The TRM-40 is Vanguard Instruments’ third generation transformer winding resistance meter. The TRM-40 is designed specifically to measure DC resistance values of transformer windings, rotating machine windings, or any dc resistance of an inductive device.
-
product
Transformer Winding Resistance Meters
RMO TD Series
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
product
Transformer Winding Resistance Meters
RMO TW Series
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.